scholarly journals LA-ICP-MS Signal Enhancement by Hydrogen Gas Addition to Carrier Gasfor the Analysis of Ultra-trace Elements in Olivine and Orthopyroxene

2021 ◽  
Author(s):  
Marina Veter ◽  
Olivier Alard ◽  
Stephen Foley
1992 ◽  
Vol 87 (4) ◽  
pp. 107-122 ◽  
Author(s):  
Takeyoshi YOSHIDA ◽  
Shin-ichi YAMASAKI ◽  
Akito TSUMURA
Keyword(s):  
Icp Ms ◽  

2009 ◽  
Vol 1215 ◽  
Author(s):  
Xinwei Wang ◽  
Gaurav Bhagat ◽  
Kevin Michael O'Brien ◽  
Karol Putyera

AbstractFF-GDMS and MIC-ICP-MS methods were developed for the determination of mg/kg- and μg/kg-level B, Mg, Al, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Zr, Mo, Sb, W and Pb in nuclear-grade graphite. Consistent results have been achieved in determining trace elements like B, Ti, Cr, Mn, Zr, Sb and Pb by both methods, which vary mostly less than ±30%, and are in line with the manufacturer reference values. On Mg, Al, Fe, Co, Zn, Mo and W, FF-GDMS analyses also show good agreement with the manufacturer's data. Continuing efforts in identifying source of interference, which has limited the MIC-ICP-MS analysis of these elements, is currently underway.


Author(s):  
Jiaxin Yu ◽  
He Zhao ◽  
Tao He ◽  
Tao Luo ◽  
Wen Zhang ◽  
...  

Our results firstly indicate that the geometry of the skimmer cone has an important effect on signal enhancement when using a heating-condensing system in ICP-MS.


2017 ◽  
Vol 9 (11) ◽  
pp. 1710-1717 ◽  
Author(s):  
Serhat Döker

A rapid dilute-and-shoot procedure was described for the ultra-trace determination of Li, Al, Cr, Mn, Co, Ni, Cu, Zn, As, Cd, Tl, Pb and U in honey by collision/reaction cell inductively coupled plasma mass spectrometry (CRC-ICP-MS).


2019 ◽  
Vol 34 (4) ◽  
pp. 741-752 ◽  
Author(s):  
Aubrey L. Galusha ◽  
Aubreian C. Haig ◽  
Michael S. Bloom ◽  
Pamela C. Kruger ◽  
Alexandra McGough ◽  
...  

Human follicular fluid was collected from 56 women undergoing IVF treatment and analyzed for 11 (ultra-)trace elements using a “dilute and shoot” ICP-MS/MS method.


2015 ◽  
Vol 30 (5) ◽  
pp. 1142-1153 ◽  
Author(s):  
Ryszard Gajek ◽  
Key-Young Choe

The relationships between signal intensities of C+, Na+and Cl+and the concentration ofn-butanol in a mixed solution ofn-butanol and NaCl. .


2018 ◽  
Vol 49 ◽  
pp. 157-163 ◽  
Author(s):  
Sören Meyer ◽  
Mariya Markova ◽  
Gabriele Pohl ◽  
Talke A. Marschall ◽  
Olga Pivovarova ◽  
...  

1992 ◽  
Vol 25 (11) ◽  
pp. 205-212 ◽  
Author(s):  
S. Yamasaki ◽  
A. Tsumura

A specially designed high resolution ICP-MS was combined with an ultrasonic nebulizer to analyze trace amounts of various inorganic contaminants contained in water samples. It was confirmed that the detection limits of most elements obtained by the proposed method were well under 1 ppt. The Standard Reference Material 1643b (trace elements in water) provided by NIST (National Institute of Standards and Technology, formerly U. S. National Bureau of Standards) was also analyzed. Concentration values obtained by this work were in good agreement with certified values for all the elements examined except for Cu. It can be concluded from the foregoing that the combination of the above two instruments materializes an extraordinarily sensitive method and paves the way for direct determination of a considerable number of trace and ultra-trace elements in water samples with acceptable speed and accuracy.


Sign in / Sign up

Export Citation Format

Share Document