scholarly journals Determination of 232Th(n, γ) reaction rate induced by D-T neutrons in one-dimensional alternate depleted uranium/polyethylene shells

2014 ◽  
Vol 63 (16) ◽  
pp. 162801
Author(s):  
Yang Yi-Wei ◽  
Liu Rong ◽  
Jiang Li ◽  
Lu Xin-Xin ◽  
Wang Mei ◽  
...  
2020 ◽  
Vol 16 ◽  
Author(s):  
Ikko Mikami ◽  
Eri Shibayama ◽  
Kengo Takagi

Background: Determination of a reducing substance based on the reaction between Ce(IV) and a reducing substance and fluorescence detection of Ce(III) generated has been reported as a selective and sensitive method. However, this method could not be applied to the determination of alcohol due to the low reaction rate of alcohol and Ce(IV). Objective: We found that thiosulfate catalytically enhanced reaction of alcohols (such as, methanol, ethanol, and propanol) and Ce(IV). Utilizing this effect, we developed a new method for the determination of alcohols. Results: In the presence of thiosulfate, an increase in fluorescence intensity was detected by injecting alcohol at concentrations of several millimolar, whereas it was not observed even at the concentration of 10% v/v (2 M for ethanol) in the absence of thiosulfate. The optimum detection conditions were determined to be 4.0 mM Ce(IV) sulfate and 0.50 mM thiosulfate, and the detection limit (S/N = 3) of ethanol under these conditions was 1 mM. In the calibration curves, changes in the slope were observed when the alcohol concentrations were approximately 10–25 mM. Using a thiosulfate solution containing ethanol as the reaction solution, a calibration curve without any change in slope was obtained, although the concentration of ethanol at the detection limit increased. The alcohols in the liquor and fuel were successfully analyzed using the proposed detection method as a postcolumn reaction. Conclusion: This new alcohol detection method using a versatile fluorescence detector can be applied to the postcolumn reaction of HPLC omitting need of time-consuming pretreatment processes.


1979 ◽  
Vol 44 (2) ◽  
pp. 401-405 ◽  
Author(s):  
Ľubica Adamčíková ◽  
Ľudovít Treindl

The kinetics and mechanism of the redox reactions of U3+ ions with mono- and dichloroacetic acids were studied. The influence of pH was observed mainly in the second case and led to the determination of the rate constants and activation parameters corresponding to two parallel steps, namely oxidation of U3+ with CHCl2COO- ions and oxidation of U3+ with CHCl2.COOH molecules. The influence of binary mixtures of water with methanol, ethanol, isopropanol, or tert-butenol on the reaction rate was followed. Increasing alcohol concentration influences the rate constant not only through changing dielectric constant and solvation of the reactants but also through a change of the solvent structure which plays a role in reactions with an outer sphere mechanism of the electron transfer.


1984 ◽  
Vol 49 (3) ◽  
pp. 673-679 ◽  
Author(s):  
Pavel Lederer ◽  
Eva Mácová ◽  
Josef Vepřek-Šiška

The decomposition of peroxobenzoic acid in benzene was studied, and catalytic effects of Fe(III), Mn(III), Co(II), Co(III), and Cr(III) on the reaction rate and the composition of the reaction mixture were investigated. An analogous experiment carried out in perdeuterobenzene and determination of the distribution of deuterium in the reaction products provided evidence for the participation of the solvent in peroxobenzoic acid decomposition.


1988 ◽  
Vol 34 (4) ◽  
pp. 736-738 ◽  
Author(s):  
D Serrano de la Cruz ◽  
E Santillana ◽  
A Mingo ◽  
G Fuenmayor ◽  
A Pantoja ◽  
...  

Abstract This one-dimensional thin-layer chromatographic method is used for assay of phospholipids in the gastric aspirate of newborns. The solvent mixture (chloroform/hexane/methanol/glacial acetic acid/water, 12/7/4/3/0.3 by vol) completely resolves lecithin, sphingomyelin, phosphatidylinositol, phosphatidylserine, phosphatidylethanolamine, and phosphatidylglycerol. The method is simple, precise, inexpensive, and rapid (chromatographic development takes less than 25 min) and gives high chromatographic resolution. We used this method to determine the lecithin/sphingomyelin densitometric ratio (L/S ratio) and the phosphatidylglycerol percentage in 200 samples of gastric aspirate and found an L/S ratio of 2.5 to be a satisfactory cutoff value for distinguishing fetal lung maturity and immaturity. We confirmed that the presence of phosphatidylglycerol excluded the possibility of respiratory distress.


2008 ◽  
Author(s):  
Sarata K. Sahoo ◽  
Hiroko Enomoto ◽  
Shinji Tokonami ◽  
Tetsuo Ishikawa ◽  
Predrag Ujić ◽  
...  

2009 ◽  
Vol 42 (2) ◽  
pp. 192-197 ◽  
Author(s):  
Thomas Gnäupel-Herold

A method is outlined that allows the determination of one-dimensional stress gradients at length scales greater than 0.2 mm. By using standard four-circle X-ray diffractometer equipment and simple aperture components, length resolutions down to 0.05 mm in one direction can be achieved through constant orientation of a narrow, line-shaped beam spot. Angle calculations are given for the adjustment of goniometer angles, and for the effective azimuth and tilt of the scattering vector for general angle settings in a four-circle goniometer. The latter is necessary for the computation of stresses from lattice strain measurements.


1998 ◽  
Vol 249-251 ◽  
pp. 175-179
Author(s):  
B. Kardynal ◽  
C.H.W. Barnes ◽  
E.H. Linfield ◽  
D.A. Ritchie ◽  
J.T. Nicholls ◽  
...  

2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Yan Gao ◽  
Kai Chang ◽  
Xuguang Xing ◽  
Jiaping Liang ◽  
Nian He ◽  
...  

PurposeTraditional laboratory measurements of soil water diffusivity (D) and soil water retention curve (SWRC) are always time-consuming and labor-intensive. Therefore, this paper aims to present a simple and robust test method for determining D and SWRC without reducing accuracy.Design/methodology/approachIn this study, a D model of unsaturated soil was established based on Gardner–Russo model and then a combination of Gardner–Russo model with one-dimensional horizontal absorption method to obtain n and a parameters of Gardner–Russo model. One-dimensional horizontal absorption experiments on loam, silt loam and sandy clay loam were conducted to obtain the relationships between measured infiltration rate and cumulative infiltration with wetting front distance. Based on the obtained relationships, the measured infiltration data from the one-dimensional horizontal absorption tests were used to calculate n and a parameters and further constructing D and SWRC.FindingsBoth the calculated D and SWRC inversed from the infiltration data were in good agreement with the measured ones that obtained from the traditional horizontal absorption method and the centrifuge method, respectively. Error analysis indicated that only the infiltration data are enough to reliably synchronously determine D and SWRC.Originality/valueA simple and robust method is proposed for synchronous determination of soil water diffusivity and water retention curve.


Sign in / Sign up

Export Citation Format

Share Document