scholarly journals RP-HPLC Method Development and Validation for the Estimation of Lumefantrine in Bulk Drug

Author(s):  
Ashish Sethiya ◽  
R. P. S. Rathore

Lumefantrine is an antimalarial agent used to treat acute uncomplicated malaria. It is administered in combination with artemether for improved efficacy. This combination therapy exerts its effects against the erythrocytic stages of Plasmodium spp. and may be used to treat infections caused by P. falciparum and unidentified Plasmodium species, including infections acquired in chloroquine-resistant areas. A reversed-phase high performance liquid chromatography (RP-HPLC) method was developed and validated for the estimation of lumefantrine in bulk drug. The separation was achieved on Thermo C18 analytical column (250 mm × 4.6 mm i.d., 5.0 μm) using 10mM KH2PO4: acetonitrile  (pH adjust 3.0 with OPA) in the ratio 20:80 v/v as mobile phase and at a flow rate of 1.0 ml/min. Detection was carried out using a UV detector at 240nm. The total chromatographic analysis time per sample was about 6.0 min with lumefantrine eluting at retention time of about 3.225 ± 0.001min. The method was validated for accuracy, precision, specificity, linearity and sensitivity. Validation studies demonstrated that this HPLC method is simple, specific, rapid, reliable and reproducible. The standard curve was linear over the concentration range of 5-25 μg/ml with r2 close to one (0.999). The limit of detection (LOD) and limit of quantitation (LOQ) obtained for lumefantrine were 0.25 μg/ml and 0.75μg/ml respectively. The high recovery and low relative standard deviation confirm the suitability of the proposed method for the determination of lumefantrine in bulk drugs.

Author(s):  
B. Mounika ◽  
L. Srikanth ◽  
A. Venkatesha

Objective: A reversed phase liquid chromatography was determined and validated for the estimation of Mirabegron in tablet dosage form.Methods: The validation study of RP-HPLC showed a simple, rapid, accurate, precise, reproducible results by using a stationary phase: Waters Acquity HSS T-3 C18 (100 × 2.1 mm, 1.7μm and Mobile Phase-Potassium di-hydrogen phosphate: acetone in the ratio (40:60 v/v) at PH6.0±0.02. Detection is carried out at 243 nm using UV detector.Results: The total chromatographic analysis time per sample was about 6 min with Mirabegron eluting at a retention time of 2.754. Tailing factor obtained from the standard injection is 1.6. Theoretical Plates obtained from the standard injection is 2736.7. The flow rate is 1 ml/min and linearity in the concentration range of 30-70μg/ml (R2=0.999). The precision was 0.4% the intermediate precision was 0.08%. The deliberately varied chromatographic conditions in the concentration range for the evaluation of robustness is 10-50 µg/ml, (n=3). The limit of detection (LOD) and limit of quantitation (LOQ) for Mirabegron were 0.01µg/ml and 0.05µg/ml respectively. The % recovery is 99.8 % with % R. SD of 0.09. The results proved that the optimized HPLC method fulfills these requirements within the ICH accepted limits.Conclusion: The high recovery and low relative standard deviation confirm the suitability of the proposed method for the determination of Mirabegron in tablet dosage form. 


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Amol S. Jagdale ◽  
Nilesh S. Pendbhaje ◽  
Rupali V. Nirmal ◽  
Poonam M. Bachhav ◽  
Dayandeo B. Sumbre

Abstract Background A new, sensitive, suitable, clear, accurate, and robust reversed-phase high-performance liquid chromatography (RP-HPLC) method for the determination of brexpiprazole in bulk drug and tablet formulation was developed and validated in this research. Surface methodology was used to optimize the data, with a three-level Box-Behnken design. Methanol concentration in the mobile phase, flow rate, and pH were chosen as the three variables. The separation was performed using an HPLC method with a UV detector and Openlab EZchrom program, as well as a Water spherisorb C18 column (100 mm × 4.6; 5m). Acetonitrile was pumped at a flow rate of 1.0 mL/min with a 10 mM phosphate buffer balanced to a pH of 2.50.05 by diluted OPA (65:35% v/v) and detected at 216 nm. Result The developed RP-HPLC method yielded a suitable retention time for brexpiprazole of 4.22 min, which was optimized using the Design Expert-12 software. The linearity of the established method was verified with a correlation coefficient (r2) of 0.999 over the concentration range of 5.05–75.75 g/mL. For API and formulation, the percent assay was 99.46% and 100.91%, respectively. The percentage RSD for the method’s precision was found to be less than 2.0%. The percentage recoveries were discovered to be between 99.38 and 101.07%. 0.64 μg/mL and 1.95 μg/mL were found to be the LOD and LOQ, respectively. Conclusion The developed and validated RP-HPLC system takes less time and can be used in the industry for routine quality control/analysis of bulk drug and marketed brexpiprazole products. Graphical abstract


Author(s):  
MADHURIMA BASAK ◽  
Santhosh Reddy Gouru ◽  
Animesh Bera ◽  
Krishna veni Nagappan

Objective: The present study aims at developing an accurate precise, rapid and sensitive Reverse Phase High-Performance Liquid Chromatography (RP-HPLC) method for assessing Empagliflozin in bulk drug and in the pharmaceutical dosage form. Methods: The proposed method employs a Reverse Phase Shim Pack C18 column (250 mm × 4.6 mm id; 5 µm) using a mobile phase comprising of acetonitrile and water in the ratio of 60:40 v/v flushed at a flow rate of 1 ml/min. The eluents were monitored at 223 nm. Results: Empagliflozin was eluted at a retention time of 5.417 min and established a co-relation co-efficient (R2>0.999) over a concentration ranging from 0.0495-100µg/ml. Percentage recovery was obtained between 98-102% which indicated that the method is accurate. The Limit of Detection (LOD) and Limit of Quantitation (LOQ) were found at 0.0125µg/ml and 0.0495µg/ml, respectively. Conclusion: An RP-HPLC method which was relatively simple, accurate, rapid and precise was developed and its validation was performed for the quantitative analysis of empagliflozin in bulk and tablet dosage form (10 and 25 mg) in accordance to International Conference of Harmonization (ICH) Q2 (R1) guidelines. The proposed method may aid in routinely analyzing empagliflozin in pharmaceuticals.


Author(s):  
Dilshad Ahmad ◽  
Faisal A. Al Meshaiti ◽  
Yazeed K. Al Anazi ◽  
Osama Al Owassil ◽  
Alaa Eldeen B. Yassin

Anastrozole, an aromatase inhibitor drug, is used for the treatment of breast cancer in pre- and postmenopausal women. Anastrozole’s incorporation into nanoparticulate carriers would enhance its therapeutic performance. To perceive the exact loaded amount of drug in nanocarriers, a valid analytical method is required. The reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated by using the C18 column, 150 × 4.6 mm, 5 µm particle size, in isocratic mobile phase composed of 50:50 V/V (volume/volume) acetonitrile–phosphate buffer (pH 3) flowing at a rate of 1.0 mL/min, and a diode array detector (DAD) set at λmax = 215 nm. The validation parameters such as linearity, accuracy, specificity, precision, and robustness have proven the accuracy of the method, with the relative standard deviation percentage (% RSD) values < 2. The limit of detection of the method was found equal to 0.0150 µg/mL, and the limit of quantitation was 0.0607 µg/mL. The percent recovery of sample was in the range of 98.04–99.25%. The method has the advantage of being rapid with a drug retention time of 2.767 min, specific in terms of resolution of peaks void of interference with any of the excipients, and high reproducibility. This makes it highly applicable for quality control purposes.


2018 ◽  
Vol 68 (2) ◽  
pp. 171-183
Author(s):  
Béla Kovács ◽  
Lajos Kristóf Kántor ◽  
Mircea Dumitru Croitoru ◽  
Éva Katalin Kelemen ◽  
Mona Obreja ◽  
...  

Abstract A reverse-phase HPLC (RP-HPLC) method was developed for strontium ranelate using a full factorial, screening experimental design. The analytical procedure was validated according to international guidelines for linearity, selectivity, sensitivity, accuracy and precision. A separate experimental design was used to demonstrate the robustness of the method. Strontium ranelate was eluted at 4.4 minutes and showed no interference with the excipients used in the formulation, at 321 nm. The method is linear in the range of 20–320 μg mL−1 (R2 = 0.99998). Recovery, tested in the range of 40–120 μg mL−1, was found to be 96.1–102.1 %. Intra-day and intermediate precision RSDs ranged from 1.0–1.4 and 1.2–1.4 %, resp. The limit of detection and limit of quantitation were 0.06 and 0.20 μg mL−1, resp. The proposed technique is fast, cost-effective, reliable and reproducible, and is proposed for the routine analysis of strontium ranelate.


2018 ◽  
Vol 17 (2) ◽  
pp. 175-182
Author(s):  
Joy Chandra Rajbangshi ◽  
Md Mahbubul Alam ◽  
Md Shahadat Hossain ◽  
Md Samiul Islam ◽  
Abu Shara Shamsur Rouf

This research was aimed to establish a versatile, sensitive, rapid and validated RP-HPLC method to analyze linagliptin in bulk as well as in pharmaceutical dosage forms. Liquid chromatography was performed on HPLC system and 20μl of samples were injected into a C18 column (150 x 4.6 mm i.d., 5μm particle size) and the eluents were monitored through a PDA detector at 239 nm. An isocratic method with a flow rate of 1 ml/min was used to elute the compounds with a mobile phase comprised of 70:30 v/v mixture of phosphate buffer (pH 6.8±0.2) and acetonitrile. The retention time of the compound was found to be 2.8 minutes. According to the ICH Q2(R1) guidelines, the method was validated by establishing several analytical parameters such as system suitability, specificity, linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), ruggedness and robustness to assay linagliptin. The method showed good linearity (R2 = 0.9981) over the concentration ranges of 40 – 60 μg/ml with a recovery between 99.48% ± 0.38% RSD to 100.22% ± 0.011% RSD, whereas the LOD and LOQ values were 0.05 μg/ml and 0.15 μg/ml, respectively. The relative standard deviation (% RSD) for inter-day and intra-day precision was not more than 2.0%. Hence, the proposed method can be applied accurately for research and routine analysis of linagliptin in bulk as well as different pharmaceutical dosage forms. Dhaka Univ. J. Pharm. Sci. 17(2): 175-182, 2018 (December)


2012 ◽  
Vol 10 (2) ◽  
pp. 67-70
Author(s):  
Abdullah Al Masud ◽  
Mohammad Saydur Rahman ◽  
Towfika Islam ◽  
Saki Sultana ◽  
Moynul Hasan ◽  
...  

A simple, reproducible and efficient reversed phase high performance liquid chromatographic (RPHPLC) method has been developed for the estimation of a recently approved anti allergic drug, amlexanox in oral paste dosage form. The separations were carried out on a Zorbax Eclipse XBD, C18 column (150 x 4.6 mm; 5?m) at a flow rate of 1.50 ml/min. by using mobile phase comprising of mixed buffer (pH adjusted to 6.50) and methanol (50:50 v/v). The injection volume was 10 ?l and the peaks were detected at 244 nm. The linear dynamic range found to be in the concentration range of 15-35 ?g/ml and coefficient of correlation was found to be 0.999. The %RSD value was below 2.0 for intra-day and inter-day precision which indicated that the method was highly precise. The LOD (Limit of detection) and LOQ (Limit of quantitation) were found to be 3.8 ng/ml and 12.5 ng/ml, respectively which revealed that the method was highly sensitive. The percentage recovery of amlexanox ranged from 99.31 to 99.75%, indicating the accuracy of the method and absence of interference from the excipients present in the formulation. The proposed method was simple, fast, accurate and reproducible and hence can be applied for routine quality control operations of amlexanox in oral paste dosage form. Key words: Amlexanox, Anti allergic, RP-HPLC, LOD, LOQ. DOI: http://dx.doi.org/10.3329/dujps.v10i2.11782 Dhaka Univ. J. Pharm. Sci. 10(2): 67-70, 2011 (December)


Author(s):  
Prabhakar V. Raut ◽  
Sudhakar L. Padwal ◽  
Madhusudhan T. Bachute ◽  
Satish A. Polshettiwar

The present study describes the dissolution method development and validation of Ramipril and Hydrochlorothiazide in tablet dosage form by HPLC Method. A simple, rapid, selective, reproducible and isocratic reversed-phase high performance liquid chromatographic (RP-HPLC) method has been developed and validated as per ICH guidelines. Analysis was performed on a Thermo, Sunniest C8 (150 mm x 4.6 mm, 5 µm) with the mobile phase consisting of mixing 500 mL of buffer solution and 500 mL of acetonitrile at a flow rate of 1.0mL/min. UV detection was performed at 210nm and the Run time for Ramipril and Hydrochlorothiazide were 10 minutes. The calibration curve was linear (correlation coefficient = 1.000) in the selected range for both analytes. The optimized dissolution conditions include the USP Type 1 (Basket) rotation rate of 100 rpm and 750 mL of 0.1 N Hydrochloric acid as dissolution medium, at 37.0 ± 0.5°C. The method was validated for precision, linearity, specificity, accuracy, limit of quantitation and ruggedness. The system suitability parameters, such as theoretical plate, tailing factor and relative standard deviation (RSD) between six standard replicates were well within the limits. The stability result shows that the drug is stable in the prescribed dissolution medium.


2010 ◽  
Vol 7 (2) ◽  
pp. 569-577 ◽  
Author(s):  
Uma Mahesh Karra ◽  
Sanjeeva Yarkala

A simple and rapid reverse phase high performance liquid chromatography (RP-HPLC) method was developed and validated for quantitative determination of rabeprazole in bulk drug samples and formulations. Rabeprazole was analyzed by using reverse phase LC-GC column (Inertsil ODS, 4.6 mm x 25 cm, 5 microns), with mobile phase consisting of methanol: water (78:22 v/v). The flow rate was set 1.0 mL/min and analysis was performed at wavelength 288 nm using Photo Diode Array (PDA) detector at ambient temperature. The method was validated and stability studies were conducted under different conditions. The retention time for rabeprazole was around 4.12 minutes. The calibration curves were linear (r≥0.9998) over a concentration range from 20.0 to 80.0 μg/mL. Limit of detection (LOD) and Limit of quantitation (LOQ) were 8 ng/mL and 24 ng/mL respectively. The developed method was successfully applied to estimate the amount of rabeprazole in tablet formulations.


Author(s):  
Alok Pratap Singh ◽  
Iti Chauhan ◽  
Snigdha Bhardwaj ◽  
Praveen Gaur ◽  
S Sadish Kumar ◽  
...  

Introduction: Azithro-mycin a semi-synthetic, azalide congener of erythro-mycin indicated in the treatment of respiratory tract infections. Various methods available for determination of Azithro-mycin, but HPLC are most versatile one. Objective: The present study is based on the development and validation of a rapid, simple high performance liquid chromatography (HPLC) method equipped with UV detector for quantitative analysis of Azithro-mycin (AZN) in suspension. Material and methods: The Method was performed by using Hypersil BDS-C18 (250 mm × 4.6 mm i.d.) column MS-II, with an isocratic mobile phase of methanol, acetonitrile and phosphate buffer pH 8 (60:30:10; v/v) with run time 15 minutes. The determinations were performed at a flow rate of 1.0ml/min, and UV detector set at 212 nm. Result and Discussion: The method was found to be specific with relative standard deviation (RSD) less than 2.09%. The method showed accuracy with RSD less than 1.34% and precision in repeatability with RSD less than 1.42%. The method was found to be linear over a wide range of concentration from 1.0 to 50.0 μg/mL (R2 = .995). Limit of detection and limit of quantification were found to be 14.40 ng/mL and 43.66 ng/mL respectively. Conclusion: It was advantageous to use UV detector over other methods employing electrochemical, photodiode array etc. as the detector, because of cheap and easy availability. The developed method fulfilled all validation parameters as per ICH and can be successfully applied to quantify percent drug content in marketed oral Azithro-mycin suspension.