scholarly journals Estimation of Radiation Dose for Adult Patients Undergoing Diagnostic X-ray Examinations of the Skull and Cervical Spine

2017 ◽  
Vol 09 (02) ◽  
pp. 33-36
Author(s):  
Mohammed A. Alkreem
2018 ◽  
Vol 184 (1) ◽  
pp. 12-27 ◽  
Author(s):  
Vasileios I Metaxas ◽  
Gerasimos A Messaris ◽  
Aristea N Lekatou ◽  
Theodore G Petsas ◽  
George S Panayiotakis

Abstract A local survey was conducted, to evaluate the radiation dose to adult patients who underwent diagnostic X-ray examinations. Patient-related and technical data were recorded, in 1504 patients, for each of the 11 individual projections, of the 7 most common examinations performed in an X-ray room, with 1 digital radiography system. The patient entrance surface air kerma (ESAK) and the effective dose (ED) were calculated based on the X-ray tube output and the exposure parameters, as well as utilisation of suitable conversion coefficients, respectively. The 75th percentiles of the distribution of the ESAK and kerma area product (KAP) values were also established. The mean, median and 75th percentiles were compared with the national reference levels and the most common values reported at the European level through the DOSE DATAMED II project. The corresponding ED values were also compared with the average values reported for all European countries. The mean ESAK, KAP and ED values along with the uncertainty U values for chest PA, chest LAT, cranium AP, cranium LAT, cervical spine AP, cervical spine LAT, lumbar spine AP, lumbar spine LAT, pelvis AP, abdomen AP, kidneys and urinary bladder (KUB) AP were 0.12 (0.001) mGy, 0.66 (0.023) mGy, 1.01 (0.034) mGy, 0.69 (0.098) mGy, 0.72 (0.014) mGy, 0.63 (0.011) mGy, 4.12 (0.050) mGy, 5.74 (0.082) mGy, 2.57 (0.024) mGy, 1.94 (0.017) mGy, 2.47 (0.073) mGy, and 0.09 (0.001) Gy cm2, 0.38 (0.012) Gy cm2, 0.32 (0.009) Gy cm2, 0.27 (0.052) Gy cm2, 0.17 (0.004) Gy cm2, 0.21 (0.006) Gy cm2, 1.18 (0.018) Gy cm2, 1.86 (0.023) Gy cm2, 1.41 (0.012) Gy cm2, 1.27 (0.010) Gy cm2, 1.28 (0.038) Gy cm2, as well as 0.01 (0.0001) mSv, 0.05 (0.0016) mSv, 0.02 (0.0006) mSv, 0.01 (0.0012) mSv, 0.03 (0.0008) mSv, 0.03 (0.0006) mSv, 0.26 (0.0038) mSv, 0.17 (0.0022) mSv, 0.20 (0.0016) mSv, 0.23 (0.0018) mSv, 0.23 (0.0068) mSv, respectively. The 75th percentiles along with the uncertainty U values for chest PA, chest LAT, cranium AP, cranium LAT, cervical spine AP, cervical spine LAT, lumbar spine AP, lumbar spine LAT, pelvis AP, abdomen AP, kidneys and urinary bladder (KUB) AP were 0.14 (0.006) mGy, 0.88 (0.031) mGy, 1.22 (0.049) mGy, 0.94 (0.098) mGy, 0.93 (0.027) mGy, 0.78 (0.013) mGy, 5.16 (0.073) mGy, 7.24 (0.134) mGy, 2.96 (0.047) mGy, 2.59 (0.036) mGy, 3.07 (0.116) mGy, as well as 0.10 (0.0006) Gy cm2, 0.51 (0.017) Gy cm2, 0.37 (0.020) Gy cm2, 0.33 (0.040) Gy cm2, 0.23 (0.007) Gy cm2, 0.26 (0.011) Gy cm2, 1.50 (0.036) Gy cm2, 2.26 (0.035) Gy cm2, 1.61 (0.023) Gy cm2, 1.67 (0.017) Gy cm2, 1.56 (0.069) Gy cm2, in terms of ESAK and KAP values, respectively. The results were significantly lower compared with the national reference levels, the most common DRL values reported at the European level and other previously reported dose values. Patient dose surveys could contribute towards optimising radiation protection for patients, therefore, highlighting the necessity to increase the awareness and knowledge of the radiation dose in conjunction with the required image quality.


2002 ◽  
Vol 57 (6) ◽  
pp. 731-734 ◽  
Author(s):  
Torgny Rasmuson ◽  
Lena Damber ◽  
Lennart Johansson ◽  
Robert Johansson ◽  
Lars-Gunnar Larsson

2017 ◽  
Vol 1 (1) ◽  
pp. 21-29
Author(s):  
Matthew Protas ◽  
Henry Wingfield ◽  
Basem Ishak ◽  
Rong Li ◽  
Rod J. Oskouian ◽  
...  

2020 ◽  
Vol 22 (Supplement_3) ◽  
pp. iii329-iii329
Author(s):  
Minako Sugiyama ◽  
Takayuki Hashimoto ◽  
Takashi Mori ◽  
Kazuya Hara ◽  
Yukayo Terashita ◽  
...  

Abstract BACKGROUND To reduce treatment-related adverse events in pediatric and young-adult patients with brain tumors, proton beam radiotherapy (PBT) has recently been performed instead of conventional X-ray radiotherapy. However, whether PBT is as effective as X-ray radiotherapy has not been sufficiently investigated, especially in patients receiving whole-ventricular irradiation. METHODS We report a retrospective observation of 15 patients with intracranial germ cell tumors (GCT), who received PBT at our institution from April 2014 to September 2019. We evaluated their clinical course, short-term adverse events, and prognosis. RESULTS/ CONCLUSION Fifteen patients (9 males and 6 females; median age 13 years) who received PBT following induction chemotherapy were analyzed. Nine patients received 23.4–27.0 GyE of whole-ventricular irradiation due to GCT in the pituitary gland, pineal body, or hypothalamic area. Three patients received 23.4 GyE of whole-brain irradiation: one of them had boost irradiation for basal ganglia. Three patients received 30.6 GyE of craniospinal irradiation (CSI). Six of the 15 patients experienced nausea (grade 2, according to the CTCAE version 4.0). Four patients, including two who received CSI, showed myelosuppression: decrease in white blood cell count, lymphocyte cell count, and neutrophil count (grade 3). No other severe short-term adverse events of >grade 2 was observed in any of the patients. At a median follow-up of 21 months (2-62 months) after irradiation. all patients are alive without recurrence. Our results may be encouraging and further investigations with a larger scale is warranted.


2020 ◽  
Vol 81 ◽  
pp. 36-37
Author(s):  
H. Barnamehei ◽  
Y. Zhou ◽  
X. Zhang ◽  
A. Vasavada

Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4554
Author(s):  
Ralph-Alexandru Erdelyi ◽  
Virgil-Florin Duma ◽  
Cosmin Sinescu ◽  
George Mihai Dobre ◽  
Adrian Bradu ◽  
...  

The most common imaging technique for dental diagnoses and treatment monitoring is X-ray imaging, which evolved from the first intraoral radiographs to high-quality three-dimensional (3D) Cone Beam Computed Tomography (CBCT). Other imaging techniques have shown potential, such as Optical Coherence Tomography (OCT). We have recently reported on the boundaries of these two types of techniques, regarding. the dental fields where each one is more appropriate or where they should be both used. The aim of the present study is to explore the unique capabilities of the OCT technique to optimize X-ray units imaging (i.e., in terms of image resolution, radiation dose, or contrast). Two types of commercially available and widely used X-ray units are considered. To adjust their parameters, a protocol is developed to employ OCT images of dental conditions that are documented on high (i.e., less than 10 μm) resolution OCT images (both B-scans/cross sections and 3D reconstructions) but are hardly identified on the 200 to 75 μm resolution panoramic or CBCT radiographs. The optimized calibration of the X-ray unit includes choosing appropriate values for the anode voltage and current intensity of the X-ray tube, as well as the patient’s positioning, in order to reach the highest possible X-rays resolution at a radiation dose that is safe for the patient. The optimization protocol is developed in vitro on OCT images of extracted teeth and is further applied in vivo for each type of dental investigation. Optimized radiographic results are compared with un-optimized previously performed radiographs. Also, we show that OCT can permit a rigorous comparison between two (types of) X-ray units. In conclusion, high-quality dental images are possible using low radiation doses if an optimized protocol, developed using OCT, is applied for each type of dental investigation. Also, there are situations when the X-ray technology has drawbacks for dental diagnosis or treatment assessment. In such situations, OCT proves capable to provide qualitative images.


2021 ◽  
pp. 1-12
Author(s):  
Ignacio O. Romero ◽  
Changqing Li

BACKGROUND: Pencil beam X-ray luminescence computed tomography (XLCT) imaging provides superior spatial resolution than other imaging geometries like sheet beam and cone beam geometries. However, the pencil beam geometry suffers from long scan times, resulting in concerns overdose which discourages the use of pencil beam XLCT. OBJECTIVE: The dose deposited in pencil beam XLCT imaging was investigated to estimate the dose from one angular projection scan with three different X-ray sources. The dose deposited in a typical small animal XLCT imaging was investigated. METHODS: A Monte Carlo simulation platform, GATE (Geant4 Application for Tomographic Emission) was used to estimate the dose from one angular projection scan of a mouse leg model with three different X-ray sources. Dose estimations from a six angular projection scan by three different X-ray source energies were performed in GATE on a mouse trunk model composed of muscle, spine bone, and a tumor. RESULTS: With the Sigray source, the bone marrow of mouse leg was estimated to have a radiation dose of 44 mGy for a typical XLCT imaging with six angular projections, a scan step size of 100 micrometers, and 106 X-ray photons per linear scan. With the Sigray X-ray source and the typical XLCT scanning parameters, we estimated the dose of spine bone, muscle tissues, and tumor structures of the mouse trunk were 38.49 mGy, 15.07 mGy, and 16.87 mGy, respectively. CONCLUSION: Our results indicate that an X-ray benchtop source (like the X-ray source from Sigray Inc.) with high brilliance and quasi-monochromatic properties can reduce dose concerns with the pencil beam geometry. Findings of this work can be applicable to other imaging modalities like X-ray fluorescence computed tomography if the imaging protocol consists of the pencil beam geometry.


2017 ◽  
Vol 27 (01n02) ◽  
pp. 37-42
Author(s):  
T. Segawa ◽  
S. Harada ◽  
S. Ehara ◽  
K. Ishii ◽  
T. Sato ◽  
...  

Encapsulated protamine-hyaluronic acid particles containing carboplatin were prepared and their ability to release carboplatin was tested in vivo. Protamine–hyaluronic acid particles containing carboplatin were prepared by mixing protamine (1.6 mg) and hyaluronic acid (1.28 mg) into a 5 mg/mL carboplatin solution for 30 min at room temperature. A 1 mL solution of protamine–hyaluronic acid particles was poured into an ampule of COATSOME[Formula: see text] EL-010 (Nichiyu, Tokyo, Japan), shaken three times by hand, and allowed to incubate at room temperature for 15 min. Following that, 10 or 20 Gy of 100 kiloelectronvolt (KeV) soft X-ray was applied. The release of carboplatin was imaged using a microparticle-induced X-ray emission (PIXE) camera. The amount of carboplatin released was expressed as the amount of platinum released and measured via quantitative micro-PIXE analysis. The diameter of the generated encapsulated particles measured [Formula: see text] nm (mean ± standard error). The release of carboplatin from the encapsulated protamine–hyaluronic acid particles was observed under a micro-PIXE camera. The amount of carboplatin released was [Formula: see text] under 10 Gy of radiation, and [Formula: see text] under 20 Gy of radiation, which was a sufficient dose for cancer treatment. However, 10 or 20 Gy of radiation is much greater than the dose used for clinical cancer treatment (2 Gy). Further research to reduce the radiation dose to 2 Gy in order to release sufficient carboplatin for cancer treatment is required.


2014 ◽  
Vol 880 ◽  
pp. 53-56 ◽  
Author(s):  
Sergei Stuchebrov ◽  
Andrey Batranin ◽  
Dan Verigin ◽  
Yelena Lukyanenko ◽  
Maria Siniagina ◽  
...  

Two setups for X-ray visualization of objects interior structure were designed and assembled in TPU. These radiographic systems are based on linear gas-discharge and GaAs semiconductor detectors. During investigation of biological object control of radiation doses has a high priority. In this report radiation dose calculations in X-ray visualization are presented. These calculation also includes dose calculations of sinograms which are used for reconstruction of tomography slices.


Sign in / Sign up

Export Citation Format

Share Document