dose efficiency
Recently Published Documents


TOTAL DOCUMENTS

63
(FIVE YEARS 15)

H-INDEX

11
(FIVE YEARS 3)

2022 ◽  
pp. 1-9
Author(s):  
Tiarnan Mullarkey ◽  
Jonathan J. P. Peters ◽  
Clive Downing ◽  
Lewys Jones

In the scanning transmission electron microscope, fast-scanning and frame-averaging are two widely used approaches for reducing electron-beam damage and increasing image signal noise ratio which require no additional specialized hardware. Unfortunately, for scans with short pixel dwell-times (less than 5 μs), line flyback time represents an increasingly wasteful overhead. Although beam exposure during flyback causes damage while yielding no useful information, scan coil hysteresis means that eliminating it entirely leads to unacceptably distorted images. In this work, we reduce this flyback to an absolute minimum by calibrating and correcting for this hysteresis in postprocessing. Substantial improvements in dose efficiency can be realized (up to 20%), while crystallographic and spatial fidelity is maintained for displacement/strain measurement.


2021 ◽  
Vol 10 (24) ◽  
pp. 5757
Author(s):  
Salim Aymeric Si-Mohamed ◽  
Jade Miailhes ◽  
Pierre-Antoine Rodesch ◽  
Sara Boccalini ◽  
Hugo Lacombe ◽  
...  

The X-ray imaging field is currently undergoing a period of rapid technological innovation in diagnostic imaging equipment. An important recent development is the advent of new X-ray detectors, i.e., photon-counting detectors (PCD), which have been introduced in recent clinical prototype systems, called PCD computed tomography (PCD-CT) or photon-counting CT (PCCT) or spectral photon-counting CT (SPCCT) systems. PCD allows a pixel up to 200 microns pixels at iso-center, which is much smaller than that can be obtained with conventional energy integrating detectors (EID). PCDs have also a higher dose efficiency than EID mainly because of electronic noise suppression. In addition, the energy-resolving capabilities of these detectors allow generating spectral basis imaging, such as the mono-energetic images or the water/iodine material images as well as the K-edge imaging of a contrast agent based on atoms of high atomic number. In recent years, studies have therefore been conducted to determine the potential of PCD-CT as an alternative to conventional CT for chest imaging.


2021 ◽  
Author(s):  
Jun Yang ◽  
Jian-Heng Huang ◽  
Yao-Hu Lei ◽  
Jing-Biao Zheng ◽  
Yu-Zheng Shan ◽  
...  

Abstract Dual phase grating interferometer may simultaneously achieve large field of view and high X-ray dose efficiency. In this paper, we developed a simple theoretical method to better understand the imaging process of the dual phase grating interferometer. The derivation process of fringe period and the optimal visibility conditions of the dual phase grating interferometer were shown in detail. Then, we theoretically proved that the fringe period and optimal visibility conditions of the dual phase grating interferometer included that of the Talbot interferometer. By comparing our experimental results with those of other researchers, we found that when the positions of phase gratings were far away from the positions where the fringe visibility was optimal, the fringe period of the dual π-phase grating interferometer was twice longer than the theoretical results under the illumination of polychromatic X-ray. And this conclusion may explain the contradictory research results of dual phase grating interferometer among different researchers.


2021 ◽  
Vol 28 (5) ◽  
pp. 1343-1356
Author(s):  
Yue Zhang ◽  
Peng-Han Lu ◽  
Enzo Rotunno ◽  
Filippo Troiani ◽  
J. Paul van Schayck ◽  
...  

Imaging of biomolecules by ionizing radiation, such as electrons, causes radiation damage which introduces structural and compositional changes of the specimen. The total number of high-energy electrons per surface area that can be used for imaging in cryogenic electron microscopy (cryo-EM) is severely restricted due to radiation damage, resulting in low signal-to-noise ratios (SNR). High resolution details are dampened by the transfer function of the microscope and detector, and are the first to be lost as radiation damage alters the individual molecules which are presumed to be identical during averaging. As a consequence, radiation damage puts a limit on the particle size and sample heterogeneity with which electron microscopy (EM) can deal. Since a transmission EM (TEM) image is formed from the scattering process of the electron by the specimen interaction potential, radiation damage is inevitable. However, we can aim to maximize the information transfer for a given dose and increase the SNR by finding alternatives to the conventional phase-contrast cryo-EM techniques. Here some alternative transmission electron microscopy techniques are reviewed, including phase plate, multi-pass transmission electron microscopy, off-axis holography, ptychography and a quantum sorter. Their prospects for providing more or complementary structural information within the limited lifetime of the sample are discussed.


Nanoscale ◽  
2021 ◽  
Author(s):  
Alexander Skorikov ◽  
Wouter Heyvaert ◽  
Wiebke Albrecht ◽  
Daan Pelt ◽  
Sara Bals

The combination of energy-dispersive X-ray spectroscopy (EDX) and electron tomography is a powerful approach to retrieve the 3D elemental distribution in nanomaterials, providing an unprecedented level of information for complex,...


2020 ◽  
Vol 53 (3) ◽  
pp. 748-759 ◽  
Author(s):  
Ming Du ◽  
Dogˇa Gürsoy ◽  
Chris Jacobsen

Different studies in X-ray microscopy have arrived at conflicting conclusions about the dose efficiency of imaging modes involving the recording of intensity distributions in the near (Fresnel regime) or far (Fraunhofer regime) field downstream of a specimen. A numerical study is presented on the dose efficiency of near-field holography, near-field ptychography and far-field ptychography, where ptychography involves multiple overlapping finite-sized illumination positions. Unlike what has been reported for coherent diffraction imaging, which involves recording a single far-field diffraction pattern, it is found that all three methods offer similar image quality when using the same fluence on the specimen, with far-field ptychography offering slightly better spatial resolution and a lower mean error. These results support the concept that (if the experiment and image reconstruction are done properly) the sample can be near or far; wherever you are, photon fluence on the specimen sets one limit to spatial resolution.


2019 ◽  
Vol 64 (24) ◽  
pp. 245003 ◽  
Author(s):  
Liqiang Ren ◽  
Kishore Rajendran ◽  
Cynthia H McCollough ◽  
Lifeng Yu

2019 ◽  
Vol 47 (2) ◽  
pp. 441-456 ◽  
Author(s):  
Liqiang Ren ◽  
Kishore Rajendran ◽  
Cynthia H. McCollough ◽  
Lifeng Yu