fast transients
Recently Published Documents


TOTAL DOCUMENTS

235
(FIVE YEARS 40)

H-INDEX

21
(FIVE YEARS 5)

2021 ◽  
Vol 11 (24) ◽  
pp. 12010
Author(s):  
Bradut-Eugen Ghidersa ◽  
Bruno Gonfiotti ◽  
André Kunze ◽  
Valentino Di Marcello ◽  
Mihaela Ionescu-Bujor ◽  
...  

The experimental investigation of a prototypical set-up simulating a loss of flow accident in a helium-cooled breeding blanket first wall mock-up under typical heat load conditions is presented. The experimental campaign reproduces the expected DEMO thermal-hydraulics conditions during normal and off-normal situations and aims at providing some insight into the fast transients associated with the loss of flow in the blanket first wall. The experimental set-up and the definition of the experimental matrix are discussed, including pre-test analysis performed in support of these activities. The major experimental results are discussed, and a procedure of using the acquired data for validating and calibrating the RELAP-3D model of the mock-up is introduced. All these activities contributed to the creation of a relevant theoretical and practical experience that can be used in further studies concerning incidental transients in real-plant scenarios in the framework of DEMO plant fusion safety activities.


2021 ◽  
Author(s):  
Andrei A. Antonov ◽  
Maksim S. Karpovich ◽  
Vladislav Yu. Vasilyev
Keyword(s):  

Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6453
Author(s):  
Andrea Mariscotti

This work addresses the problem of power quality (PQ) metrics (or indexes) suitable for DC grids, encompassing low and medium voltage applications, including electric transports, all-electric ships and aircrafts, electric vehicles, distributed generation and microgrids, modern data centers, etc. The two main pillars on which such PQ indexes are discussed and built are: (i) the physical justification, so the electric phenomena affecting DC grids and components (PV panels, fuel cells, capacitors, batteries, etc.), causing, e.g., stress of materials, aging, distortion, grid instability; and (ii) the existing standardization framework, pointing out desirable coverage and extension, similarity with AC grids standards, but also inconsistencies. For the first point, each phenomenon is discussed with quantitative conclusions on relevant thresholds: in many cases some percentage of distortion (ripple) is acceptable (stress on capacitors and storage, impact on fuel cells, and PV panels), whereas in other cases, much higher levels may be tolerated (interference to protection and monitoring devices). Standards are reviewed for indications not only of low-order harmonics and voltage fluctuations typical of old DC grid schemes, but also for high-frequency noise, including thus supraharmonics and common-mode disturbance, and filling the gap with the electromagnetic compatibility domain. However, phenomena typical of EMC and electrical safety (such as various types of overvoltages and fast transients) are excluded. Suitable PQ indexes are then reviewed, suggesting integrations and modifications, to cover the relevant phenomena and technological progress, and to better follow the normative exigencies: ripple is considered in time and frequency domain, in particular with a band limited implementation; for transients and pulsed loads, more traditional indexes based on area, energy, and half duration are confronted with indexes evaluating the power trajectory and its derivative.


2021 ◽  
Vol 42 (2) ◽  
Author(s):  
Y. Sharma ◽  
A. Marathe ◽  
V. Bhalerao ◽  
V. Shenoy ◽  
G. Waratkar ◽  
...  
Keyword(s):  

Author(s):  
Subramania Prasad Visakan ◽  
Mandava Mohana Rao ◽  
Mritunjay Kumar ◽  
Karakkad Sunitha

Abstract Very Fast Transient Over voltages (VFTOs) generate during operation of the disconnector switches or circuit breakers in a gas insulated substation (GIS). These transient voltages stress the insulation system in GIS and further result in mal-operation of the control circuitry as well as the secondary equipment connected to it. Since the VFTOs affect the reliability of GIS, it is necessary to mitigate them. This paper presents the mitigation of the very fast transient over voltages and the associated very fast transient currents (VFTCs) using the nano-crystalline rings in a 245 kV GIS. The mitigation in the peak amplitude of VFTOs and VFTCs at various locations in the GIS for various switching configurations are analyzed in this paper. The nano-crystalline rings of different geometries and permeabilities are considered to understand the damping effect being offered. The nano-crystalline rings are considered at all the possible switches of 245 kV GIS bays. An equivalent circuit model of the nano-crystalline ring is obtained through an iterative algorithm. The very fast transients have been calculated using Electromagnetic Transients Program software. Further, attenuation in the dominant frequency components of VFTOs and VFTCs at different GIS components is also studied for various switching configurations with nano-crystalline rings.


Author(s):  
Cherie K. Day ◽  
Adam T. Deller ◽  
Clancy W. James ◽  
Emil Lenc ◽  
Shivani Bhandari ◽  
...  

Abstract The recent increase in well-localised fast radio bursts (FRBs) has facilitated in-depth studies of global FRB host properties, the source circumburst medium, and the potential impacts of these environments on the burst properties. The Australian Square Kilometre Array Pathfinder (ASKAP) has localised 11 FRBs with sub-arcsecond to arcsecond precision, leading to sub-galaxy localisation regions in some cases and those covering much of the host galaxy in others. The method used to astrometrically register the FRB image frame for ASKAP, in order to align it with images taken at other wavelengths, is currently limited by the brightness of continuum sources detected in the short-duration (‘snapshot’) voltage data captured by the Commensal Real-Time ASKAP Fast Transients (CRAFT) software correlator, which are used to correct for any frame offsets due to imperfect calibration solutions and estimate the accuracy of any required correction. In this paper, we use dedicated observations of bright, compact radio sources in the low- and mid-frequency bands observable by ASKAP to investigate the typical astrometric accuracy of the positions obtained using this so-called ‘snapshot’ technique. Having captured these data with both the CRAFT software and ASKAP hardware correlators, we also compare the offset distributions obtained from both data products to estimate a typical offset between the image frames resulting from the differing processing paths, laying the groundwork for future use of the longer duration, higher signal-to-noise ratio (S/N) data recorded by the hardware correlator. We find typical offsets between the two frames of ${\sim}0.6$ and ${\sim}0.3$ arcsec in the low- and mid-band data, respectively, for both RA and Dec. We also find reasonable agreement between our offset distributions and those of the published FRBs. We detect only a weak dependence in positional offset on the relative separation in time and elevation between target and calibrator scans, with the trends being more pronounced in the low-band data and in Dec. Conversely, the offsets show a clear dependence on frequency in the low band, which we compare to the frequency-dependent Dec. offsets found in FRB 200430. In addition, we present a refined methodology for estimating the overall astrometric accuracy of CRAFT FRBs.


Sign in / Sign up

Export Citation Format

Share Document