carotid baroreceptor
Recently Published Documents


TOTAL DOCUMENTS

182
(FIVE YEARS 16)

H-INDEX

25
(FIVE YEARS 2)

2022 ◽  
Vol 75 (1) ◽  
pp. e24-e25
Author(s):  
Santiago Mier y Teran-Ellis ◽  
Humberto A. Estrada-Rodriguez ◽  
Javier E. Anaya-Ayala ◽  
Gabriel Lopez-Pena ◽  
Emmanuel A. Contreras-Jimenez ◽  
...  

2021 ◽  
Vol 14 (12) ◽  
pp. e244881
Author(s):  
Ellery Altshuler ◽  
Mahmoud Aryan ◽  
Jess Delaune ◽  
James Lynch

We present a case of a 77-year-old man who reported 5 months of syncopal episodes. He was found to have diffuse large B-cell lymphoma encasing the left internal carotid artery but not impeding blood flow. The syncopal episodes resolved after his first cycle of chemotherapy. Recurrent syncope in non-cardiac lymphomas and other head and neck masses is exceedingly rare and may be due to reflex syncope prompted by carotid baroreceptor activation. There are 11 previously described cases of recurrent syncope associated with non-cardiac lymphoma. In all cases, lymphadenopathy abutting the carotid artery was present and the syncopal episodes resolved with treatment. Our case illustrates that malignancy should be considered in patients with unexplained recurrent syncope.


2021 ◽  
Vol 31 (5) ◽  
pp. 1635-1644
Author(s):  
Qiao Yu ◽  
Ling Shu ◽  
Lang Wang ◽  
Kaile Gao ◽  
Jing Wang ◽  
...  

2021 ◽  
Vol 14 (4) ◽  
Author(s):  
Zain I. Sharif ◽  
Vincent Galand ◽  
William J. Hucker ◽  
Jagmeet P. Singh

Symptomatic heart failure (HF) patients despite optimal medical therapy and advances such as invasive hemodynamic monitoring remain challenging to manage. While cardiac resynchronization therapy remains a highly effective therapy for a subset of HF patients with wide QRS, a majority of symptomatic HF patients are poor candidates for such. Recently, cardiac contractility modulation, neuromodulation based on carotid baroreceptor stimulation, and phrenic nerve stimulation have been approved by the US Food and Drug Administration and are emerging as therapeutic options for symptomatic HF patients. This state-of-the-art review examines the role of these evolving electrical therapies in advanced HF.


Author(s):  
Gino Seravalle ◽  
Fosca Quarti-Trevano ◽  
Jennifer Vanoli ◽  
Chiara Lovati ◽  
Guido Grassi

Abstract Purpose The present paper will review the impact of different therapeutic interventions on the autonomic dysfunction characterizing chronic renal failure. Methods We reviewed the results of the studies carried out in the last few years examining the effects of standard pharmacologic treatment, hemodialysis, kidney transplantation, renal nerve ablation and carotid baroreceptor stimulation on parasympathetic and sympathetic control of the cardiovascular system in patients with renal failure. Results Drugs acting on the renin–angiotensin system as well as central sympatholytic agents have been documented to improve autonomic cardiovascular control. This has also been shown for hemodialysis, although with more heterogeneous results related to the type of dialytic procedure adopted. Kidney transplantation, in contrast, particularly when performed together with the surgical removal of the native diseased kidneys, has been shown to cause profound sympathoinhibitory effects. Finally, a small amount of promising data are available on the potential favorable autonomic effects (particularly the sympathetic ones) of renal nerve ablation and carotid baroreceptor stimulation in chronic kidney disease. Conclusions Further studies are needed to clarify several aspects of the autonomic responses to therapeutic interventions in chronic renal disease. These include (1) the potential to normalize sympathetic activity in uremic patients by the various therapeutic approaches and (2) the definition of the degree of sympathetic deactivation to be achieved during treatment.


2020 ◽  
Vol 6 (4) ◽  
pp. 132-142
Author(s):  
Pratik V Paliwal ◽  
Prathamesh H Kamble ◽  
K A Desai ◽  
Rajesh Sharma ◽  
Anish Singhal

This paper presents the design, development and testing of a novel neck chamber device for non-invasive stimulation of an individual carotid baroreceptor in a graded manner. The proposed neck chamber device is a strap-free design that avoids discomfort during testing due to tight seal generated by the neck collar design, and facilitates unilateral testing and targeted assessment without stimulating other neck baroreceptors. The device consists of two independent components to achieve these requirements: an outer suction mechanism and an inner chamber. The outer mechanism consists of multiple suction cups to grip the device over the human neck, while the inner chamber creates controlled positive and negative pressure for stimulation of baroreceptors using a pump. The indigenously developed device was employed for the testing by providing neck chamber stimulation in discrete steps of –20 mm Hg, –40 mm Hg, −60 mm Hg, 0 mm Hg, 20 mm Hg, 40 mm Hg and 60 mm Hg with the gap of 60 s between each stimulation as per the standard test protocol of autonomic function test. The changes in heart rate and RR interval were recorded to determine the baroreceptor gain using the logistic equation derivative and gain curve plot. The results of the present study show that the estimated baroreceptor gain is –0.109±0.04, which is consistent with the previous studies conducted using neck collar devices. The testing results showed that the desired objectives are achieved successfully by the prototype device, opening up the possibility of its use for the treatment of resistant hypertension.


F1000Research ◽  
2020 ◽  
Vol 9 ◽  
pp. 169 ◽  
Author(s):  
Michael Doumas ◽  
Konstantinos P Imprialos ◽  
Manolis S Kallistratos ◽  
Athanasios J Manolis

The management of resistant hypertension presents several challenges in everyday clinical practice. During the past few years, several studies have been performed to identify efficient and safe pharmacological and non-pharmacological options for the management of such patients. The Spironolactone versus placebo, bisoprolol, and doxazosin to determine the optimal treatment for drug-resistant hypertension (PATHWAY-2) trial demonstrated significant benefits with the use of spinorolactone as a fourth-line drug for the treatment of resistant hypertension over doxazosin and bisoprolol. In addition, recent data support that spironolactone may demonstrate superiority over central acting drugs in such patients, as well. Based on the European guidelines, spironolactone is recommended as the fourth-line drug option, followed by amiloride, other diuretics, doxazosin, bisoprolol or clonidine.  Among several device-based approaches, renal sympathetic denervation had fallen into hibernation after the disappointing results of the Renal Denervation in Patients With Uncontrolled Hypertension (SYMPLICITY HTN) 3 trial. However, the technique re-emerged at the epicenter of the clinical and research interest after the favorable results of three sham-controlled studies, which facilitated novel catheters and techniques to perform the denervation. Significant results of iliac anastomosis on blood pressure levels have also been demonstrated. Nevertheless, the technique-related adverse events resulted in withdrawal of this interventional approach. Last, the sympatholytic properties of the carotid baroreceptor activation therapy were associated with significant blood pressure reductions in patients with resistant hypertension, which need to be verified in larger controlled trials. Currently device-based approaches are recommended only in the setting of clinical trials until more safety and efficacy data become available.


2019 ◽  
Vol 29 (01) ◽  
pp. 033-038
Author(s):  
Thomas Kotsis ◽  
Panagitsa Christoforou ◽  
Konstantinos Nastos

AbstractThe technique of the eversion carotid endarterectomy (ECEA), as an alternative to the conventional endarterectomy with primary or patch angioplasty, is an established technique for managing internal carotid artery stenoses and recently its application has been upgraded through the European Society for Vascular Surgery guidelines (Recommendation 55: Class 1, Level A). However, the typical eversion method has been associated with postoperative hypertension due to loss of the baroreceptor reflex; the standard oblique transection at the bulb performed in the eversion endarterectomy interrupts either the baroreceptor sensoring tissue, which is mostly located in the adventitia at the medial portion of the proximal internal carotid artery, or even the proper Hering nerve, a branch of the glossopharyngeal nerve. These actions deregulate the natural negative feedback of the carotid baroreceptor. Guided by the anatomical location of the baroreceptor sensor we have elaborated a slight modification of the classical ECEA to maintain as much as possible of the viable carotid baroreceptor sensoring surface. By extending the oblique incision distal to the carotid bifurcation in the medial part of the internal carotid artery stem, an eyebrow-like part of the proximal internal carotid artery is maintained and the axis from the sensoring tissue to the nerve of Hering is protected and following the endarterectomy, postoperative arterial blood pressure levels are lower than in the classical ECEA due to the maintenance of the efficiency of the baroreceptor reflex. During the period from September 2016 to November 2018, carotid endarterectomy was performed in 57 patients. Twenty-eight of them underwent the typical ECEA and 29 patients had the modified eyebrow eversion carotid endarterectomy (me-ECEA). The changes of blood pressure baseline during the postoperative course in ECEA and me-ECEA group were analyzed and compared. Postoperative hypertension was defined as an elevation of systolic blood pressure (SBP) greater than 140 mm Hg. Patients who underwent typical ECEA had significantly higher postoperative blood pressure values compared with those who underwent me-ECEA. Actually, the mean postoperative SBP was 172.67 ± 24.59 mm Hg in the typical ECEA group compared with 160.86 ± 12.83 mm Hg in the me-ECEA group (p = 0.023). The mean diastolic blood pressure in the ECEA group was 65.42 ± 11.39 mm Hg compared with 58.06 ± 9.06 mm Hg in the me-ECEA group (p = 0.009). Our proposed me-ECEA technique seems to be related to lower rates of postoperative hypertension compared with the typical ECEA, probably due to the sparing of the main mass of the baroreceptor apparatus; this improved modification (me-ECEA) of the typical eversion procedure could represent an alternative ECEA technique with its inherent advantages.


Sign in / Sign up

Export Citation Format

Share Document