pinhole imaging
Recently Published Documents


TOTAL DOCUMENTS

85
(FIVE YEARS 7)

H-INDEX

14
(FIVE YEARS 1)

2021 ◽  
Vol 103 ◽  
pp. 107146
Author(s):  
Wen Long ◽  
Jianjun Jiao ◽  
Ximing Liang ◽  
Tiebin Wu ◽  
Ming Xu ◽  
...  

2021 ◽  
Vol 92 (4) ◽  
pp. 043524
Author(s):  
D. B. Schaeffer ◽  
W. Fox ◽  
M. J. Rosenberg ◽  
H.-S. Park ◽  
G. Fiksel ◽  
...  

2020 ◽  
Vol 6 (10) ◽  
pp. 100 ◽  
Author(s):  
Muhammad Abir ◽  
Daniel S. Hussey ◽  
Boris Khaykovich

We present and compare the designs of three types of neutron microscopes for high-resolution neutron imaging. Like optical microscopes, and unlike standard neutron imaging instruments, these microscopes have both condenser and image-forming objective optics. The optics are glancing-incidence axisymmetric mirrors and therefore suitable for polychromatic neutron beams. The mirrors are designed to provide a magnification of 10 to achieve a spatial resolution of better than 10 μm. The resolution of the microscopes is determined by the mirrors rather than by the L/Dratio as in conventional pinhole imaging, leading to possible dramatic improvements in the signal rate. We predict the increase in the signal rate by at least two orders of magnitude for very high-resolution imaging, which is always flux limited. Furthermore, in contrast to pinhole imaging, in the microscope, the samples are placed far from the detector to allow for a bulky sample environment without sacrificing spatial resolution.


2018 ◽  
Vol 8 (8) ◽  
pp. 1399 ◽  
Author(s):  
Na Zhao ◽  
Changku Sun ◽  
Peng Wang

Orthogonally splitting imaging pose sensor is a new sensor with two orthogonal line array charge coupled devices (CCDs). Owing to its special structure, there are distortion correction and imaging model problems during the calibration procedure. This paper proposes a calibration method based on the general imaging model to solve these problems. The method introduces Plücker Coordinate to describe the mapping relation between the image coordinate system and the world coordinate system. This paper solves the mapping relation with radial basis function interpolation and adaptively selecting control points with Kmeans clustering method to improve the fitting accuracy. This paper determines the appropriate radial basis function and its shape parameter by experiments. And these parameters are used to calibrate the orthogonally splitting imaging pose sensor. According to the calibration result, the root mean square (RMS)of calibration dataset and the RMS of test dataset are 0.048 mm and 0.049 mm. A comparative experiment is conducted between the pinhole imaging model and the general imaging model. Experimental results show that the calibration method based on general imaging model applies to the orthogonally splitting imaging pose sensor. The calibration method requires only one image corresponding to the target in the world coordinates and distortion correction is not required to be taken into account. Compared with the calibration method based on the pinhole imaging model, the calibration procedure based on the general imaging model is easier and accuracy is greater.


2018 ◽  
Vol 63 (14) ◽  
pp. 145002 ◽  
Author(s):  
Yusuke Watanabe ◽  
Hiroshi Muraishi ◽  
Hideyuki Takei ◽  
Hidetake Hara ◽  
Tsuyoshi Terazaki ◽  
...  

2018 ◽  
pp. 1-16 ◽  
Author(s):  
Olga Gourgenovna Olkhovskaya ◽  
Vladimir Anontol’evich Gasilov ◽  
Alexey Mikhailovich Kotelnikov ◽  
Mikhail Vladimirovich Yakobovskiy

Sign in / Sign up

Export Citation Format

Share Document