chemical shift mri
Recently Published Documents


TOTAL DOCUMENTS

53
(FIVE YEARS 8)

H-INDEX

19
(FIVE YEARS 2)

2021 ◽  
Vol 94 (1119) ◽  
pp. 20200710
Author(s):  
Niels van Vucht ◽  
Rodney Santiago ◽  
Ian Pressney ◽  
Asif Saifuddin

Objective: To determine its ability of in-phase (IP) and out-of-phase (OOP) chemical shift imaging (CSI) to distinguish non-neoplastic marrow lesions, benign bone tumours and malignant bone tumours. Methods: CSI was introduced into our musculoskeletal tumour protocol in May 2018 to aid in characterisation of suspected bone tumours. The % signal intensity (SI) drop between IP and OOP sequences was calculated and compared to the final lesion diagnosis, which was classified as non-neoplastic (NN), benign neoplastic (BN) or malignant neoplastic (MN). Results: The study included 174 patients (84 males; 90 females: mean age 44.2 years, range 2–87 years). Based on either imaging features (n = 105) or histology (n = 69), 44 lesions (25.3%) were classified as NN, 66 (37.9%) as BN and 64 (36.8%) as MN. Mean % SI drop on OOP for NN lesions was 36.6%, for BN 3.19% and for MN 3.24% (p < 0.001). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy of CSI for differentiating NN from neoplastic lesions were 65.9%, 94.6%, 80.6%, 89.1%% and 87.4% respectively, and for differentiating BN from MN were 9.1%, 98.4%, 85.7%, 51.2 and 53.1% respectively. Conclusion: CSI is accurate for differentiating non-neoplastic and neoplastic marrow lesions, but is of no value in differentiating malignant bone tumours from non-fat containing benign bone tumours. Advances in knowledge: CSI is of value for differentiating non-neoplastic marrow lesions from neoplastic lesions, but not for differentiating benign bone tumours from malignant bone tumours as has been previously reported.


2019 ◽  
Vol 44 (10) ◽  
pp. 3359-3369
Author(s):  
İlhan Hekimsoy ◽  
Ezgi Güler ◽  
Mustafa Harman ◽  
Nevra Elmas

2019 ◽  
Vol 26 (1) ◽  
pp. 107327481986528 ◽  
Author(s):  
Phung Anh Tuan ◽  
Mai Van Vien ◽  
Hoang Van Dong ◽  
David Sibell ◽  
Bui Van Giang

The aim of the study was to evaluate the usefulness of computed tomography (CT) and magnetic resonance imaging (MRI) for differentiating thymoma from nonthymoma abnormalities in patients with myasthenia gravis (MG). A cross-sectional study of 53 patients with MG, who had undergone surgical thymectomy, was conducted at 103 Hospital (Hanoi, Vietnam) and Cho Ray Hospital (Ho Chi Minh City, Vietnam) during August 2014 and January 2017. The CT and MRI images of patients with MG were qualitatively and quantitatively (radiodensity and chemical shift ratio [CSR]) analyzed to determine and compare their ability to distinguish thymoma from nonthymoma abnormalities. Logistic regression was used to identify the association between imaging parameters (eg, CSR) and the thymoma status. The receiver operating curve (ROC) analysis was used to determine the differentiating ability of CSR and radiodensity. As results, of the 53 patients with MG, 33 were with thymoma and 20 were with nonthymoma abnormalities. At qualitative assessment, MRI had significantly higher accuracy than did CT in differentiating thymoma from nonthymoma abnormalities (94.3% vs 83%). At quantitative assessment, both the radiodensity and CSR were significantly higher for thymoma compared with nonthymoma groups ( P < .001). The ROC analysis showed that CSR had significantly higher sensitivity (Se) and specificity (Sp) than radiodensity in discriminating between the 2 groups (CSR: Se 100%, Sp 95% vs radiodensity: Se 90.9%, Sp 70%). When combining both qualitative and quantitative parameters, MRI had even higher accuracy than did CT in thymoma diagnosis ( P = .031). In conclusion, chemical shift MRI was more accurate than CT for differentiating thymoma from nonthymoma in patients with MG.


2018 ◽  
Vol 51 (3) ◽  
pp. 156-161 ◽  
Author(s):  
Flávia Martins Costa ◽  
Clarissa Canella ◽  
Filipa Gomes Vieira ◽  
Evandro Miguelote Vianna ◽  
Walter Meohas ◽  
...  

Abstract Objective: The purpose of this study was to determine whether chemical-shift magnetic resonance imaging (MRI) could be useful in the diagnosis of osteoid osteoma when clinical and radiological tumor features are inconclusive. Materials and Methods: This retrospective study included 17 patients who underwent chemical-shift MRI for the evaluation of osteoid osteoma. For all patients, two musculoskeletal radiologists independently recorded signal intensities on in-phase and out-of-phase images in the nidus of the tumor, in abnormal-intensity bone marrow surrounding the lesion, and in normal-appearing bone marrow. For each region, relative signal intensity ratios were calculated by dividing out-of-phase by in-phase values. Relative ratios > 1 were considered indicative of neoplastic lesions. Statistical analysis was carried out to analyze the sample. Inter-observer and intra-observer agreement for each imaging method were assessed using intraclass correlation coefficients according to the Fleiss method and a value > 0.65 was considered to indicate substantial agreement. Results: The mean relative signal intensity ratios were 1.2 (range, 0.9-1.4) for the nidus and 0.35 (range, 0.11-0.66) for the surrounding tissue; these values differed significantly from the relative signal-intensity ratios for normal-appearing bone marrow (p < 0.05). Conclusion: Chemical-shift MRI is useful for the diagnosis and evaluation of osteoid osteoma.


2018 ◽  
Vol 104 (6) ◽  
pp. NP57-NP60
Author(s):  
Lucio Calandriello ◽  
Anna Rita Larici ◽  
Giuliano Sica ◽  
Mario Ciliberto ◽  
Riccardo Manfredi

Thymolipoma is a rare tumor of the thymus. Classic radiologic findings of thymolipoma include fatty masses of the anterior mediastinum in conjunction with the thymus. Differential diagnosis with other more aggressive entities like liposarcoma and teratoma can be challenging. We report a case where chemical shift magnetic resonance imaging helped in the differential diagnosis.