ito electrode
Recently Published Documents


TOTAL DOCUMENTS

358
(FIVE YEARS 74)

H-INDEX

38
(FIVE YEARS 8)

Author(s):  
Yuta Tsubonouchi ◽  
Masashi Kajita ◽  
Taichi Hayasaka ◽  
Hamada S. A. Mandour ◽  
Mohamed R Berber ◽  
...  

Platinum nanoparticles (PAA-Pt) stabilized by polyacrylic acid (PAA) of a polymeric stabilizer were adsorbed on an indium tin oxide (ITO) surface from their colloidal solution due to the chemical adsorption...


Author(s):  
Md. Fahamidul Islam ◽  
Riad H. Rakib ◽  
Khalid A. Alamry ◽  
Mohammed M. RahmanHasnat

Sensors ◽  
2021 ◽  
Vol 21 (24) ◽  
pp. 8338
Author(s):  
Haruto Eguchi ◽  
Akihiko Hatano ◽  
Yasuo Yoshimi

Vancomycin (VCM) is a first-line antimicrobial agent against methicillin-resistant Staphylococcus aureus, a cause of nosocomial infections. Therapeutic drug monitoring is strongly recommended for VCM-based chemotherapy. The authors attempted to develop a simple VCM sensor based on molecularly imprinted polymer (MIP), which can be used with simple operations. Methacrylic acid (MAA), acrylamide, methylenebisacrylamide, and allylamine carboxypropionate-3-ferrocene (ACPF) were copolymerized in the presence of VCM and grafted from the surface of indium-tin oxide (ITO) to obtain MIP-coated electrodes. The MIP-grafted ITO electrode was used for differential pulse voltammetry (DPV) measurements in a buffer solution containing VCM or whole bovine blood. The obtained current depends on the VCM concentration with high linearity. The dynamic range covered the therapeutic range (20–40 μg/mL) of the VCM but was almost insensitive to teicoplanin, which has a similar structure to VCM. The ITO electrodes grafted by the same procedure except for omitting either VCM or APCF were not sensitive to VCM. The sensitivity of the MIP electrodes to VCM in whole blood and buffered saline, but the background current in blood was higher than that in saline. This high background current was also seen in the deproteinized plasma. Thus, the current is probably originated from the oxidation of low molecular weight reducing agents in the blood. The MIP-grafted ITO electrode using ACPF as a functional monomer would be a promising highly selective sensor for real-time monitoring of VCM with proper correction of the background current.


Author(s):  
Tuan Van Nguyen ◽  
Ha Huu Do ◽  
Wenwu Guo ◽  
Mahider Tekalne ◽  
Quyet Van Le ◽  
...  

2021 ◽  
Vol 21 (11) ◽  
pp. 5666-5672
Author(s):  
Z. Z. Wang ◽  
P. F. Wu ◽  
H. Y. Yue ◽  
X. Gao ◽  
Y. Y. Ma ◽  
...  

Zinc sulfide nanospheres (ZnS NSs) were prepared by hydrothermal synthesis and graphene oxide (GO) was prepared by the Hummer’s method. ZnS NSs-rGO/ITO electrode was synthesized by heat treatment at a certain temperature, which was used for the detailed electrochemical determination of levodopa (LD). Finally, they were annealed to form the ZnS NSs-rGO/ITO electrode for detecting levodopa (LD). The results reveal that the ZnS NSs with the diameter of ~1 μm are covered by rGO. The ZnS NSs-rGO/ITO electrode has a good sensitivity of 1.43 μA μM −1 for the determination of LD in the concentration range of 1–40 μM. Moreover, it also shows a good selectivity, reproducibility and stability. In order to verify the practicability, we also use the electrode to detect LD in human serum. The detection results also prove that the electrode can be used in real life.


2021 ◽  
Author(s):  
Jibril Al-Metairi ◽  
Ruba Ali ◽  
Shoaib Mallic ◽  
Zubair Ahmed ◽  
Noora Al-Thani

In this research work, we have studied the impact of UV/ozone treatment on the hydrophilicity of the PVDF-BaTiO3 nanocomposite film. We have prepared the nanocomposite solution by mixing PVDF (2.5 wt% kept constant) and BaTiO3 nanoparticles (0.25 wt%, 0.5 wt%, and 1 wt% varied concentration). The spin coating technique has been used to deposit the nanocomposite film on the Interdigitated ITO electrode.


2021 ◽  
pp. 151603
Author(s):  
Yongxiang Wang ◽  
Jinming Zeng ◽  
Zuohao Zhou ◽  
Guocan Shen ◽  
Ting Tang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document