denture cleansers
Recently Published Documents


TOTAL DOCUMENTS

141
(FIVE YEARS 34)

H-INDEX

21
(FIVE YEARS 1)

Hygiene ◽  
2021 ◽  
Vol 1 (3) ◽  
pp. 129-139
Author(s):  
Naoya Imaizumi ◽  
Toshitsugu Sakurai ◽  
Masatsugu Hirota ◽  
Tohru Hayakawa ◽  
Chikahiro Ohkubo

Denture plaque control for the prevention of aspiration pneumonia is very important. The pellicle is the major cause of denture plaque adhesion. Few basic studies have evaluated the effectiveness of denture cleansers for pellicles composed of salivary proteins. The adhesion of salivary proteins formed on denture base metal and the removal rate were quantitatively analyzed using the QCM method after denture cleanser injection. This is the first study to compare the cleaning effects of denture cleanser on denture base metal using the QCM method. Au and Ti sensors were employed as the denture base metals. Albumin was used for the adsorption of salivary proteins. The results showed that no significant difference was found between Au and Ti in the amounts of albumin adsorbed, and the rate of albumin removal from Ti was significantly higher than that of Au. In this study, the cleaning effectiveness of denture cleanser was confirmed based on the adsorbed amount and the removal rate of salivary proteins adsorbed onto denture base metals. Thus, the QCM method was suggested to be a useful tool for removing the effects of salivary proteins from denture cleaning agents on denture base metal.


2021 ◽  
Vol 11 (21) ◽  
pp. 10367
Author(s):  
Christina Maillet ◽  
Serge Odof ◽  
Mikaël Meuret ◽  
Florian Le Bras ◽  
Frédéric Velard ◽  
...  

Denture stomatitis is a disease involving C. albicans, which can affect elderly and immuno-compromised people. To avoid any recurrence of this pathology, it is necessary to treat patients regularly and disinfect dentures. However, the denture cleansers’ efficacy is not optimal and often leads to adverse color effects on the denture base resins. The aim of this study was to investigate the efficacy of a low-pressure non-thermal O2 plasma (NTP) treatment on C. albicans seeded on ProBase®Hot resin (Ivoclar Vivadent). The viability reduction of C. albicans was assessed by colony forming units (CFU) analysis and by scanning electron microscopy (SEM). The effect of repeated treatments on the resin color was evaluated by spectrophotometry. The resin samples were placed in a sealed bag in which O2 plasma was generated in low-pressure conditions. The results showed that a 120-min O2 NTP treatment led to a 6-log reduction of C. albicans viability (p < 0.05) and to yeasts’ major alterations observed by SEM. Furthermore, significant slight color changes of the resin (∆E00 = 1.33) were noted only after six plasma treatments (p < 0.05). However, the denture aesthetic was preserved, as the color changes were not perceptible and remained below the acceptability threshold (∆E00 < 4).


2021 ◽  
Vol 17 (3) ◽  
pp. 153-153
Author(s):  
Min-Young Ko ◽  
Hyun-Jun Yoo ◽  
Myung-Gu Lee ◽  
Yeol-Mae Jeon ◽  
Da-Hui Kim ◽  
...  

2021 ◽  
Vol 17 (3) ◽  
pp. 108-116
Author(s):  
Min-Young Ko ◽  
Ja-Won Cho ◽  
Hyun-Jun Yoo ◽  
Myung-Gu Lee ◽  
Yeol-Mae Jeon ◽  
...  

Author(s):  
Afnan F Alfouzan ◽  
Alhanouf N. AlNouwaisar ◽  
Njood F AlAzzam ◽  
Hanan N. Al-Otaibi ◽  
Nawaf Labban ◽  
...  

Coatings ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 962
Author(s):  
Saurabh Jain ◽  
Mohammed Sayed ◽  
Walaa Magdy Ahmed ◽  
Amjad Hussain Asiri Halawi ◽  
Naif Mohammed Ahmed Najmi ◽  
...  

The current literature lacks substantial information about the effect of denture cleansers on the color stability of denture bases formed using Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) additive and CAD/CAM subtractive manufacturing techniques. This study aimed to assess the effect of two commercially available denture cleansers on the color stability of denture base resins fabricated using four different techniques. Forty-five disc-shaped specimens were fabricated using each technique. Initial color readings were recorded. Specimens were randomly divided into three subgroups (n = 15): a control group (distilled water) and two denture cleanser groups. They were immersed in these solutions, simulating 180 days of use. Final color readings were recorded. The color difference was calculated, and the data were statistically analyzed. For all the specimens, significant color changes were observed after immersion in denture cleanser solutions. The extent of color change varied according to the type of denture cleanser used. When placed in the denture cleanser solutions, the CAD/CAM subtractive group showed the maximum color change (−1.10 and −0.72), while the CAD/CAM additive (3D printing) groups showed the least color change (−0.48 and −0.54). Clinicians should choose appropriate denture cleansers for newly introduced denture base resins to minimize the changes in the color of the dentures.


Author(s):  
Samet Tekin

The aim of this in vitro study was to compare the long-term effect of overnight use of denture cleansers with different chemical compositions on the color stability of denture base polymers (DBPs). The four DBPs evaluated were PEEK (PK group), thermoinjection-molded polyamide (PA group), auto-polymerized polymethylmethacrylate (PMMA) (AP group), and heat-polymerized resin PMMA (HP group). The cleaning agents used were Corega tablet (CT), Protefix tablet (PT), and 0.5% sodium hypochlorite (NaOCl) solution (SH). Distilled water (DW) served as a control. Forty-eight disc-shaped specimens (10mm × 2mm) were prepared from each DBP and randomly immersed in the different storage media (n=12 in each group). Color measurements of the specimens before and after immersion in the denture cleansers were made using a spectrophotometer (VITA Easyshade V). The color changes were measured and recorded in L* a* b*. After 120 d, the CIEDE2000 formula was used to calculate color changes (∆E00). For analysis of the data, a multivariate analysis of variance was used (p<0.05).  The results of the statistical analysis revealed significant color change differences in the DBPs immersed in the various denture cleansers (p<0.05). Groups PA and PK showed the highest values for all solutions. AP-SH showed the highest ∆E00 value in group AP, no significant difference was found between other solutions. In group HP, there was no statistically significant difference between the average ∆E00 values of all solutions.  Long-term daily use of the denture cleansers affected the color stability of all the DBPs, although the level of color change was acceptable. Laboratory and clinical studies on the color stability of PEEK are needed to confirm the results of this study.


2021 ◽  
Vol 12 (5) ◽  
pp. 192-195
Author(s):  
Samir Sahib Merajun Nabi Khan ◽  
Syed Nazia Masoom ◽  
Siddarth Shukla ◽  
Akash Gopi ◽  
Mohsin Khan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document