porcine lungs
Recently Published Documents


TOTAL DOCUMENTS

61
(FIVE YEARS 6)

H-INDEX

14
(FIVE YEARS 0)

2021 ◽  
Author(s):  
Les Bogdanowicz ◽  
Onur Fidaner ◽  
Donato Ceres ◽  
Alex Grycuk ◽  
David Demos

UNSTRUCTURED Lung cancer is the world’s leading cause of cancer deaths, and diagnosis remains challenging. Lung cancer starts as small nodules; early and accurate diagnosis allows timely surgical resection of malignant nodules while avoiding unnecessary surgery in patients with benign nodules. The Cole Relaxation Frequency (CRF) is a derived electrical bioimpedance signature, which may be utilized to distinguish cancerous tissues from normal tissues. Here we show that CRF allows for diagnosis of cancer in human subjects, based on evaluation of 60 specimens obtained from 30 patients. We observed clear discrimination of CRF values in tumor and distant normal tissues, resulting in a high degree of sensitivity (97%) and specificity (87%) in cancer diagnosis. Furthermore, we tested 20 xenograft small animal model specimens, observing a similar separation of CRF values as in the human in-vivo measurements. We also obtained CRF measurements in pressurized and unpressurized lungs by implanting tumors into ex-vivo porcine lungs. CRF measurements align with previous tests in human and small animal models.



Author(s):  
Jan Michael Burg ◽  
Veronika Flatten ◽  
Matthias Witt ◽  
Larissa Derksen ◽  
Uli Weber ◽  
...  

Abstract In particle therapy of lung tumors, modulating effects on the particle beam may occur due to the microscopic structure of the lung tissue. These effects are caused by the heterogeneous nature of the lung tissue and cannot be completely taken into account during treatment planning, because these micro structures are too small to be fully resolved in the planning CT. In several publications, a new material parameter called modulation power (P mod ) was introduced to characterize the effect. For various artificial lung surrogates, this parameter was measured and published by other groups and ranges up to approximately 1000 µm. Studies investigating the influence of the modulation power on the dose distribution during irradiation are using this parameter in the rang of 100 to 800 µm. More precise measurements for P mod on real lung tissue have not yet been published. In this work, the modulation power of real lung tissue was measured using porcine lungs in order to produce more reliable data of P mod for real lung tissue. For this purpose, ex-vivo porcine lungs were frozen in a ventilated state and measurements in a carbon ion beam were performed. Due to the way the lungs were prepared and transferred to a solid state, the lung structures that modulate the beam could also be examined in detail using micro CT imaging. An optimization of the established methods of measuring the modulation power, which takes better account of the typical structures within lung tissue, was developed as well.



2021 ◽  
Author(s):  
Les Bogdanowicz ◽  
Onur Fidaner ◽  
Donato Ceres ◽  
Alex Grycuk ◽  
Davis Demos

Abstract Lung cancer is the world’s leading cause of cancer deaths, and diagnosis remains challenging. Lung cancer starts as small nodules; early and accurate diagnosis allows timely surgical resection of malignant nodules while avoiding unnecessary surgery in patients with benign nodules. The Cole Relaxation Frequency (CRF) is a derived electrical bioimpedance signature, which may be utilized to distinguish cancerous tissues from normal tissues. Here we show that CRF allows for diagnosis of cancer in human subjects, based on evaluation of 60 specimens obtained from 30 patients. We observed clear discrimination of CRF values in tumor and distant normal tissues, resulting in a high degree of sensitivity (97%) and specificity (87%) in cancer diagnosis. Furthermore, we tested 20 xenograft small animal model specimens, observing a similar separation of CRF values as in the human in-vivo measurements. We also obtained CRF measurements in pressurized and unpressurized lungs by implanting tumors into ex-vivo porcine lungs. CRF measurements align with previous tests in human and small animal models.



Author(s):  
Bénédicte Bonnet ◽  
Ilyass Tabiai ◽  
George Rakovich ◽  
Frédérick P. Gosselin ◽  
Isabelle Villemure
Keyword(s):  


Life ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 517
Author(s):  
Jonard Corpuz Valdoz ◽  
Dallin J. Jacobs ◽  
Collin G. Cribbs ◽  
Benjamin C. Johnson ◽  
Brandon M. Hemeyer ◽  
...  

Research in fields studying cellular response to surface tension and mechanical forces necessitate cell culture tools with tunability of substrate stiffness. We created a scalable hydrogel dish design to facilitate scaffold-free formation of multiple spheroids in a single dish. Our novel design features inner and outer walls, allowing efficient media changes and downstream experiments. The design is easily scalable, accommodating varying numbers of microwells per plate. We report that non-adherent hydrogel stiffness affects spheroid morphology and compaction. We found that spheroid morphology and viability in our hydrogel dishes were comparable to commercially available Aggrewell™800 plates, with improved tunability of surface stiffness and imaging area. Device function was demonstrated with a migration assay using two investigational inhibitors against EMT. We successfully maintained primary-derived spheroids from murine and porcine lungs in the hydrogel dish. These features increase the ability to produce highly consistent cell aggregates for biological research.



2021 ◽  
Author(s):  
Benedicte Bonnet ◽  
Ilyass Tabiai ◽  
George Rakovich ◽  
Frederick P Gosselin ◽  
Isabelle Villemure

During thoracic operations, surgical staplers resect cancerous tumors and seal the spared lung. However, post-operative air leaks are undesirable clinical consequences: staple legs wound lung tissue. Subsequent to this trauma, air leaks from lung tissue into the pleural space. This affects the lung's physiology and patients' recovery. The objective is to biomechanically and visually characterize porcine lung tissue with and without staples in order to gain knowledge on air leakage following pulmonary resection. Therefore, a syringe pump filled with air inflates and deflates eleven porcine lungs cyclically without exceeding 10 cmH2O of pressure. Cameras capture stereo-images of the deformed lung surface at regular intervals while a microcontroller simultaneously records the alveolar pressure and the volume of air pumped. The raw images are then used to compute tri-dimensional displacements and strains with the Digital Image Correlation method (DIC). Air bubbles originated at staple holes of inner row from exposed porcine lung tissue due to torn pleural on costal surface. Compared during inflation, left upper or lower lobe resections have similar compliance (slope of the pressure vs volume curve), which are 9% lower than healthy lung compliance. However, lower lobes statistically burst at lower pressures than upper lobes (p-value<0.046) in ex vivo conditions confirming previous clinical in vivo studies. In parallel, the lung deformed mostly in the vicinity of staple holes and presented maximum shear strain near the observed leak location. To conclude, a novel technique DIC provided concrete evidence of the post-operative air leaks biomechanics. Further studies could investigate causal relationships between the mechanical parameters and the development of an air leak.



PLoS ONE ◽  
2020 ◽  
Vol 15 (12) ◽  
pp. e0244382
Author(s):  
Madeleine Bonert ◽  
Moritz Schneider ◽  
Olga Solyanik ◽  
Katharina Hellbach ◽  
David Bondesson ◽  
...  

Objective CT serves as gold standard for the evaluation of pulmonary nodules. However, CT exposes patients to ionizing radiation, a concern especially in screening scenarios with repeated examinations. Due to recent technological advances, MRI emerges as a potential alternative for lung imaging using 3D steady state free precession and ultra-short echo-time sequences. Therefore, in this study we assessed the performance of three state-of-the-art MRI sequences for the evaluation of pulmonary nodules. Methods Lesions of variable sizes were simulated in porcine lungs placed in a dedicated chest phantom mimicking a human thorax, followed by CT and MRI examinations. Two blinded readers evaluated the acquired MR-images locating and measuring every suspect lesion. Using the CT-images as reference, logistic regression was performed to investigate the sensitivity of the tested MRI-sequences for the detection of pulmonary nodules. Results For nodules with a diameter of 6 mm, all three sequences achieved high sensitivity values above 0.91. However, the sensitivity dropped for smaller nodules, yielding an average of 0.83 for lesions with 4 mm in diameter and less than 0.69 for lesions with 2 mm in diameter. The positive predictive values ranged between 0.91 and 0.96, indicating a low amount of false positive findings. Furthermore, the size measurements done on the MR-images were subject to a bias ranging from 0.83 mm to -1.77 mm with standard deviations ranging from 1.40 mm to 2.11 mm. There was no statistically significant difference between the three tested sequences. Conclusion While showing promising sensitivity values for lesions larger than 4 mm, MRI appears to be not yet suited for lung cancer screening. Nonetheless, the three tested MRI sequences yielded high positive predictive values and accurate size measurements; therefore, MRI could potentially figure as imaging method of the chest in selected follow-up scenarios, e.g. of incidental findings subject to the Fleischner Criteria.



2020 ◽  
Vol 8 (1) ◽  
Author(s):  
Sofie Ordies ◽  
Michaela Orlitova ◽  
Tobias Heigl ◽  
Annelore Sacreas ◽  
Anke Van Herck ◽  
...  

Abstract Background Ex vivo lung perfusion (EVLP) is a widespread accepted platform for preservation and evaluation of donor lungs prior to lung transplantation (LTx). Standard lungs are ventilated using volume-controlled ventilation (VCV). We investigated the effects of flow-controlled ventilation (FCV) in a large animal EVLP model. Fourteen porcine lungs were mounted on EVLP after a warm ischemic interval of 2 h and randomized in two groups (n = 7/group). In VCV, 7 grafts were conventionally ventilated and in FCV, 7 grafts were ventilated by flow-controlled ventilation. EVLP physiologic parameters (compliance, pulmonary vascular resistance and oxygenation) were recorded hourly. After 6 h of EVLP, broncho-alveolar lavage (BAL) was performed and biopsies for wet-to-dry weight (W/D) ratio and histology were taken. The left lung was inflated, frozen in liquid nitrogen vapors and scanned with computed tomography (CT) to assess regional distribution of Hounsfield units (HU). Results All lungs endured 6 h of EVLP. Oxygenation was better in FCV compared to VCV (p = 0.01) and the decrease in lung compliance was less in FCV (p = 0.03). W/D ratio, pathology and BAL samples did not differ between both groups (p = 0.16, p = 0.55 and p = 0.62). Overall, CT densities tended to be less pronounced in FCV (p = 0.05). Distribution of CT densities revealed a higher proportion of well-aerated lung parts in FCV compared to VCV (p = 0.01). Conclusions FCV in pulmonary grafts mounted on EVLP is feasible and leads to improved oxygenation and alveolar recruitment. This ventilation strategy might prolong EVLP over time, with less risk for volutrauma and atelectrauma.



2020 ◽  
Vol Volume 15 ◽  
pp. 7251-7262
Author(s):  
Yoann Montigaud ◽  
Jérémie Pourchez ◽  
Lara Leclerc ◽  
Olivier Tillement ◽  
Anthony Clotagatide ◽  
...  


Sign in / Sign up

Export Citation Format

Share Document