orifice opening
Recently Published Documents


TOTAL DOCUMENTS

14
(FIVE YEARS 3)

H-INDEX

2
(FIVE YEARS 0)

Author(s):  
B. Krishna Kanth ◽  
C. Ramana ◽  
S. Joseph Reddy ◽  
L. Eadukondalu ◽  
B. Ravindra Reddy

The electrostatic induction mechanism, which superimposes charges on pesticide spray droplets, creates an impact on deposition and wraparound effect on leaf surfaces Smaller droplets have a higher capability to charge accumulation over the surface of the droplet as compared with larger droplets. This paper studied the effect of nozzle type (flat fan, hollow cone, and full cone nozzle), orifice area (1 and 1.5 mm2), and operating pressure (3-5kg cm-2) on spray droplet characteristics on soil bin. Water-sensitive papers were analysed by image analysis software to get the droplet characteristics.   The smallest droplets of a hollow cone, flat fan, and full cone were 130, 142, and 279.76 µm respectively produced at 5kg cm-2 and orifice opening 1 mm2.  With an increase of pressure droplet size and relative span was decreased for all selective nozzle. From the selected nozzles, the lowest relative span of 0.89 was found with a hollow cone nozzle at 5 kg cm-2 pressure and orifice size of 1 mm2. Among all the selected nozzles hollow cone nozzle produced the smallest droplet sizes and lowest relative span for all selected parameters.


Цель исследования: сравнительный анализ применения эндоректального ультразвукового исследования без контрастирования и с контрастированием в оценке топических характеристик свищевого хода при свищах заднего прохода. Материал и методы исследования: обследовано 49 пациентов с диагнозом “свищ заднего прохода”, из них 34 (69,4%) мужчины, 15 (30,6%) женщин. Средний возраст пациентов - 41,2 ± 13,8 года (M ± σ) (27-54 года). Всем пациентам выполнены различные оперативные вмешательства. Эндоректальные ультразвуковые исследования (без контрастирования и с контрастированием 1,5%-м раствором перекиси водорода) выполнялись одним врачом на ультразвуковом аппарате Hi Vision Preirus (Hitachi, Япония) с использованием внутриполостного линейного датчика с частотой 5-10 МГц. Результаты исследования: чувствительность, специфичность, предсказательная ценность положительного теста, предсказательная ценность отрицательного теста и точность эндоректального ультразвукового исследования с контрастированием в выявлении затеков составляют 95,2, 71,4, 95,2, 71,4 и 91,8% против 76,2, 57,1, 91,4, 28,6 и 73,5% при эндоректальном ультразвуковом исследовании без контрастирования. В выявлении внутреннего свищевого отверстия и определении его локализации достоверных различий между эндоректальным ультразвуковым исследованием без контрастирования и с контрастированием не выявлено (P > 0,05). В определении типа свища по отношению к наружному сфинктеру заднего прохода и его взаимоотношения с порциями наружного сфинктера (при транссфинктерных свищах) достоверных различий между эндоректальным ультра звуковым исследованием безконтрастирования и с контрастированием также не выявлено (P > 0,05). Однако чувствительность диагностики вовлечения поверхностной и глубокой порций наружного сфинктера при контрастировании увеличилась до 100,0% (с 66,7 и 71,4% соответственно). Заключение: результаты исследования свидетельствуют о целесообразности применения эндоректального ультразвукового исследования с контрастированием при оценке топических характеристик свища заднего прохода в сложных диагностических ситуациях, в частности для выявления высоких и (или) комбинированных затеков. Ключевые слова: эндоректальное ультразвуковое исследование без контрастирования, эндоректальное ультразвуковое исследование с контрастированием, свищ заднего прохода, внутреннее свищевое отверстие, наружное свищевое отверстие, conventional endorectal ultrasound, intracavitary contrast-enhanced endorectal ultrasound, anal fistula (fistula-in-ano), internal fistula orifice (opening), external (cutaneous) fistul


2017 ◽  
Author(s):  
Wenjia Lei ◽  
Miao Fan ◽  
Meilian Wang ◽  
Yu Wang ◽  
Wei Sun ◽  
...  

Aims: Foramen ovale (FO) valve with a shape or motion abnormality is frequently detected during routine obstetric ultrasonic examinations. However, the hemodynamics mechanism of this entity remains unclear. The purpose of the study is to determine the relevance of interatrial communication restriction and resultant morphological modifications.Materials and methods: We reviewed the echocardiographic records of fetuses with isolated abnormal FO valve evaluated between January of 2010 and december of 2016. The size (DFO) of the FO orifice, opening angle (α) of the FO valve, and dimensions of cardiac chambers, FO channel outlet (DOUT) and inferior vena cava (DIVC) were measured. We evaluated their (DFO, DOUT, α) relationships to the diameters of RA and DIVC. Five hundred and seventy normal fetuses were selected to establish the normal range of the DOUT/DIVC ratio so as to provide a criterion for restriction.Results: An abnormal FO valve was identified in 89 fetuses without congenital heart disease, with restriction noted in 62 fetuses (45 fetuses with RA dilatation, 12 fetuses with RA and RV dilatation, and 5 fetuses with no RA dilatation). There were no significant correlations between RA/LA and DFO/DIVC, RA/ LA and α. RA/LA was negatively correlated with DOUT/DIVC (R2=0.97, p<0.01).Conclusions: For a fetus with an abnormal FO valve, right heart dilatation could be considered as an indicator of interatrial communication restriction, which could be assessed by evaluating the FO channel outlet. The degree of right atrium dilatation indicates the severity of the restriction.


2013 ◽  
Vol 13 (1) ◽  
pp. 80-83
Author(s):  
Gattu Praveen Kumar ◽  
Md Shaffiuddin

Mitral valve having a double orifice opening into the left ventricle is an uncommon anomaly, In this case study we describe about a 25 years old female who came to cardiology outpatient block with exertional dysnea , the abnormality was suspected by a murmur ,further investigation Colour Doppler echocardiography showed congenital double-orifice mitral valve. This finding was confirmed by open heart surgery, and her mitral valve was successfully repaired. DOI: http://dx.doi.org/10.3329/bjms.v13i1.17442 Bangladesh Journal of Medical Science Vol. 13 No. 01 January2014: 80-83


Author(s):  
Mohamed Gharib

Variable diameter orifice is required in many applications e.g. smokestacks coal furnaces, liquid dispensing machines, wall fans, gas handling systems, pipes, vacuum chambers air valves, fluid control systems, ventilation systems, ducts, spot lights, holes of golf sports, photography nozzles, solid free fabrications and vacuum valves [1–17]. The need for variable diameter is to control the medium transfer through the orifice. In this abstract, a new design for a variable diameter orifice is introduced. Designing a variable diameter orifice is a challenging problem due to the need of circular geometry of the orifice opening. Many designs have been conducted to design a variable diameter orifice. However, the proposed designs are either have non circular opening or require a bulky size mechanism. In the proposed design, simplicity, size and actuation are our main concern.


2008 ◽  
Vol 6 (1) ◽  
pp. 8-12 ◽  
Author(s):  
Zhi-xin Yang ◽  
Jin-ling Bian ◽  
Jun-feng Xu ◽  
Peng-fei Shen ◽  
Jie Xiong ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document