artifact formation
Recently Published Documents


TOTAL DOCUMENTS

66
(FIVE YEARS 13)

H-INDEX

15
(FIVE YEARS 2)

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Vanessa Franziska Schmidt ◽  
Federica Arnone ◽  
Olaf Dietrich ◽  
Max Seidensticker ◽  
Marco Armbruster ◽  
...  

AbstractNeedle artifacts pose a major limitation for MRI-guided interventions, as they impact the visually perceived needle size and needle-to-target-distance. The objective of this agar liver phantom study was to establish an experimental basis to understand and reduce needle artifact formation during MRI-guided abdominal interventions. Using a vendor-specific prototype fluoroscopic T1-weighted gradient echo sequence with real-time multiplanar acquisition at 1.5 T, the influence of 6 parameters (flip angle, bandwidth, matrix, slice thickness, read-out direction, intervention angle relative to B0) on artifact formation of 4 different coaxial MR-compatible coaxial needles (Nitinol, 16G–22G) was investigated. As one parameter was modified, the others remained constant. For each individual parameter variation, 2 independent and blinded readers rated artifact diameters at 2 predefined positions (15 mm distance from the perceived needle tip and at 50% of the needle length). Differences between the experimental subgroups were assessed by Bonferroni-corrected non-parametric tests. Correlations between continuous variables were expressed by the Bravais–Pearson coefficient and interrater reliability was quantified using the intraclass classification coefficient. Needle artifact size increased gradually with increasing flip angles (p = 0.002) as well as increasing intervention angles (p < 0.001). Artifact diameters differed significantly between the chosen matrix sizes (p = 0.002) while modifying bandwidth, readout direction, and slice thickness showed no significant differences. Interrater reliability was high (intraclass correlation coefficient 0.776–0.910). To minimize needle artifacts in MRI-guided abdominal interventions while maintaining optimal visibility of the coaxial needle, we suggest medium-range flip angles and low intervention angles relative to B0.


Author(s):  
Felix H. Blankenstein ◽  
Ulrike Kielburg ◽  
Ludwig Melerowitz ◽  
Daniel Stelmaszczyk

Abstract Aim Metal dental products lack precautionary statements regarding MR compatibility due to an exemption in the labelling obligation. Hence, it is difficult for radiologists to decide whether to remove fixed metal objects in patients prior to MRI. A solution could be the direct determination of the magnetic permeability (µr) as a decisive material-related predictor of artifact formation and other interactions. Thus, the applicability of an industrially used measurement device as a screening instrument and the relevance of the manufacturer’s application restrictions in vitro and in vivo were tested. Methods Precision and trueness were tested using self-made test objects with different dimensions and different permeability. To clarify whether the measurement results are affected by the remanence (BR) induced in the objects, 28 brackets of different materials were exposed to a weak and a strong external magnetic field and the magnetic flux density before and after these exposures was compared. The clinical test was performed on a volunteer with an orthodontic appliance experimentally composed of brackets with different levels of magnetic permeability (µr). Validity and intra- and interrater reliability were calculated using two rater groups consisting of four dentists and four medical-technical radiology assistants (MTRA), respectively. Results With coefficients of variation below 0.14%, precision was excellent regardless of object surface and size. Trueness was high on objects with µr ≤ 1.002, and decreased with increasing µr, for which size-dependent correction factors were calculated. Intra- and interrater reliability and validity were excellent and independent of professional intraoral manipulation experience. Conclusions The permeability measurement allows for a valid and reliable determination of the magnetizability of intraoral metal objects. When used as a screening tool to detect nonartifact-causing objects, no correction factor needs to be calculated. For the first time, it offers radiologists a decision support for the selective removal of only the highly permeable components of the multiband apparatus.


Diagnostics ◽  
2021 ◽  
Vol 11 (9) ◽  
pp. 1666
Author(s):  
Marcello Demi

Currently, the diagnostic value of the artefactual information provided by lung ultrasound images is widely recognized by physicians. In particular, the existence of a correlation between the visual characteristics of the vertical artifacts, which arise from the pleura line, and the genesis (pneumogenic or cardiogenic) of a pulmonary disorder is commonly accepted. Physicians distinguish vertical artifacts from vertical artifacts which extend to the bottom of the screen (B-lines) and common vertical artifacts from well-structured artifacts (modulated B-lines). However, the link between these visual characteristics and the causes which determine them is still unclear. Moreover, the distinction between short and long artifacts and the distinction between common and structured artifacts are not on/off, and their classification can be critical. In order to derive further information from the visual inspection of the vertical artifacts, the mechanisms which control the artifact formation must be identified. In this paper, the link between the visual characteristics of the vertical artifacts (the observed effect) and the distribution of the aerated spaces at the pleural level (the cause) is addressed. Plausible mechanisms are suggested and illustrated through experimental results.


2021 ◽  
Author(s):  
Glenn Patriquin ◽  
Ross Davidson ◽  
Todd F Hatchette ◽  
Breanne M Heade ◽  
Edgard Mejia ◽  
...  

Objectives: Antigen-based rapid diagnostics tests (Ag-RDTs) are useful tools for SARS-CoV-2 detection. However, misleading demonstrations of the Abbott Panbio COVID-19 Ag-RDT on social media claimed that SARS-CoV-2 antigen could be detected in municipal water and food products. To offer a scientific rebuttal to pandemic misinformation and disinformation, this study explored the impact of using the Panbio SARS-CoV-2 assay with conditions falling outside of manufacturer recommendations. Methods: Using Panbio, various water and food products, laboratory buffers, and SARS-CoV-2-negative clinical specimens were tested, with and without manufacturer buffer. Additional experiments were conducted to assess the role of each Panbio buffer component (tricine, NaCl, pH, and tween-20), as well as the impact of temperatures (4°C, 20°C , and 45°C) and humidity (90%) on assay performance. Results: Direct sample testing (without the kit buffer), resulted in false positive signals resembling those obtained with SARS-CoV-2-positive controls tested under proper conditions. The likely explanation of these artifacts is non-specific interactions between the SARS-CoV-2-specific conjugated and capture antibodies, as proteinase K treatment abrogated this phenomenon, and thermal shift assays showed pH-induced conformational changes under conditions promoting artifact formation. Omitting, altering, and reverse engineering the kit buffer all supported the importance of maintaining buffering capacity, ionic strength, and pH for accurate kit function. Interestingly, the Panbio assay could tolerate some extremes of temperature and humidity outside of manufacturer claims. Conclusions: Our data support strict adherence to manufacturer instructions to avoid false positive SARS-CoV-2 Ag-RDT reactions, otherwise resulting in anxiety, overuse of public health resources, and dissemination of misinformation.


2021 ◽  
Vol 8 (3) ◽  
pp. 118-123
Author(s):  
Asma Asadian ◽  
Mirsepehr Pedram ◽  
Mohamad Mehdi Dehghan ◽  
Javad Sadeghinejad ◽  
Majid Masoudifard ◽  
...  

Background: Although various studied have been done to improve therapeutic strategies in resolving spinal cord injuries, robust clinical treatment is not yet available. Developing a standard animal model is essential to achieve effective treatment for such injuries. The present study was performed to introduce a simple, applicable, and minimally invasive approach for access to epidural space in cats. Methods: We used a percutaneous approach from the lumbosacral junction for stainless steel cannula insertion to the epidural space without fluoroscopy. CT scan, conventional magnetic resonance imaging (MRI), tractography, and behavioral evaluation were used to assess the correct position of the cannula and the neurological condition of the animal. Results: MRI results showed no significant change in signal intensity index of neural structures under lumbosacral junction. These observations are further supported by tractography, and also behavioral examination during the study. Conclusion: We found that the percutaneous approach from the lumbosacral junction is a simple and applicable approach that has no side effects and artifact formation in MRI evaluation.


Atmosphere ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 61
Author(s):  
Trieu-Vuong Dinh ◽  
Jo-Chun Kim

A continuous emission monitoring system (CEMS) is a well-known tool used to analyze the concentrations of air pollutants from stationary sources. In a CEMS, the presence of a high moisture level in a sample causes a loss of analytes due to artifact formation or absorption. This issue brings about a bias in the measurement data. Thus, moisture removal is an important pretreatment step. Condensation and permeation methods have been widely employed to remove moisture from the CEMS for gaseous compounds. In terms of particulate matter, dilution methods have been applied to reduce the moisture level in the gas stream. Therefore, condensation, permeation, and dilution methods are critically reviewed in this work. The removal efficiencies and recovery rates of analytes are discussed, as well as the advantages and disadvantages of each technique. Furthermore, the suitable applications of each technique are determined. Condensation methods have not been well documented so far, while permeation and dilution methods have been continuously studied. Many types of permeation materials have been developed. The limitations of each method have been overcome over the years. However, the most reliable technique has not yet been discovered.


2019 ◽  
Vol 179 ◽  
pp. 104714
Author(s):  
Bettina Haezeleer ◽  
Ute Böttger ◽  
Jean-Pierre de Vera ◽  
Franziska Hanke ◽  
Stefan Fox ◽  
...  
Keyword(s):  

2019 ◽  
Vol 47 (21) ◽  
pp. e141-e141 ◽  
Author(s):  
Antoine Daunay ◽  
Alex Duval ◽  
Laura G Baudrin ◽  
Olivier Buhard ◽  
Victor Renault ◽  
...  

Abstract Microsatellites are polymorphic short tandem repeats of 1–6 nucleotides ubiquitously present in the genome that are extensively used in living organisms as genetic markers and in oncology to detect microsatellite instability (MSI). While the standard analysis method of microsatellites is based on PCR followed by capillary electrophoresis, it generates undesirable frameshift products known as ‘stutter peaks’ caused by the polymerase slippage that can greatly complicate the analysis and interpretation of the data. Here we present an easy multiplexable approach replacing PCR that is based on low temperature isothermal amplification using recombinase polymerase amplification (LT-RPA) that drastically reduces and sometimes completely abolishes the formation of stutter artifacts, thus greatly simplifying the calling of the alleles. Using HT17, a mononucleotide DNA repeat that was previously proposed as an optimal marker to detect MSI in tumor DNA, we showed that LT-RPA improves the limit of detection of MSI compared to PCR up to four times, notably for small deletions, and simplifies the identification of the mutant alleles. It was successfully applied to clinical colorectal cancer samples and enabled detection of MSI. This easy-to-handle, rapid and cost-effective approach may deeply improve the analysis of microsatellites in several biological and clinical applications.


2019 ◽  
Author(s):  
Jochen M. Reichel ◽  
Thomas Vomhof ◽  
Jens Michaelis

AbstractWe investigate the influence of different accuracy-detection rate trade-offs on image reconstruction in single molecule localization microscopy. Our main focus is the investigation of image artifacts experienced when using low localization accuracy, especially in the presence of sample drift and inhomogeneous background. In this context we present a newly developed SMLM software termed FIRESTORM which is optimized for high accuracy reconstruction. For our analysis we used in silico SMLM data and compared the reconstructed images to the ground truth data. We observe two discriminable reconstruction populations of which only one shows the desired localization behavior.


Sign in / Sign up

Export Citation Format

Share Document