scholarly journals The technical reliability and stability of ATN quantification using the Fujirebio Lumipulse G1200 fully‐automated immunoassay instrument in cerebrospinal fluid

2021 ◽  
Vol 17 (S5) ◽  
Author(s):  
Amanda M. Celia ◽  
Christopher E. Ramirez ◽  
Bianca A. Trombetta ◽  
Kathryn LaCasse ◽  
Zoe A. Mattingly ◽  
...  
2018 ◽  
Author(s):  
Daniel Alcolea ◽  
Jordi Pegueroles ◽  
Laia Muñoz ◽  
Valle Camacho ◽  
Diego López-Mora ◽  
...  

AbstractINTRODUCTIONThe development of fully automated immunoassay platforms has improved the technical reliability of cerebrospinal fluid (CSF) biomarkers for Alzheimer’s disease.METHODSWe quantified Aβ1-42, Aβ1-40, tTau and pTau levels using the Lumipulse G System in 94 CSF samples from participants of the SPIN cohort with available 18F-Florbetapir imaging. Amyloid scans were assessed visually and through automated quantification. We determined the cutoffs of CSF biomarkers that optimized their agreement with 18F-Florbetapir PET and evaluated concordance between markers of the amyloid category.RESULTSAβ1-42, tTau and pTau (but not Aβ1-40) and the ratios with Aβ1-42 had good diagnostic agreement with 18F-Florbetapir PET. As a marker of amyloid pathology, the Aβ1-42/Aβ1-40 ratio had higher agreement and better correlation with amyloid PET than Aβ1-42 alone.DISCUSSIONCSF biomarkers measured with the Lumipulse G System show good agreement with amyloid imaging. Combination of Aβ1-42 with Aβ1-40 increases the agreement between markers of amyloid pathology.


PLoS ONE ◽  
2018 ◽  
Vol 13 (3) ◽  
pp. e0193707 ◽  
Author(s):  
Bianca A. Trombetta ◽  
Becky C. Carlyle ◽  
Aaron M. Koenig ◽  
Leslie M. Shaw ◽  
John Q. Trojanowski ◽  
...  

Author(s):  
Johan Gobom ◽  
Lucilla Parnetti ◽  
Pedro Rosa-Neto ◽  
Martin Vyhnalek ◽  
Serge Gauthier ◽  
...  

Abstract Objectives The core cerebrospinal fluid (CSF) biomarkers; total tau (tTau), phospho-tau (pTau), amyloid β 1-42 (Aβ 1-42), and the Aβ 1-42/Aβ 1-40 ratio have transformed Alzheimer’s disease (AD) research and are today increasingly used in clinical routine laboratories as diagnostic tools. Fully automated immunoassay instruments with ready-to-use assay kits and calibrators has simplified their analysis and improved reproducibility of measurements. We evaluated the analytical performance of the fully automated immunoassay instrument LUMIPULSE G (Fujirebio) for measurement of the four core AD CSF biomarkers and determined cutpoints for AD diagnosis. Methods Comparison of the LUMIPULSE G assays was performed with the established INNOTEST ELISAs (Fujirebio) for hTau Ag, pTau 181, β-amyloid 1-42, and with V-PLEX Plus Aβ Peptide Panel 1 (6E10) (Meso Scale Discovery) for Aβ 1-42/Aβ 1-40, as well as with a LC-MS reference method for Aβ 1-42. Intra- and inter-laboratory reproducibility was evaluated for all assays. Clinical cutpoints for Aβ 1-42, tTau, and pTau was determined by analysis of three cohorts of clinically diagnosed patients, comprising 651 CSF samples. For the Aβ 1-42/Aβ 1-40 ratio, the cutpoint was determined by mixture model analysis of 2,782 CSF samples. Results The LUMIPULSE G assays showed strong correlation to all other immunoassays (r>0.93 for all assays). The repeatability (intra-laboratory) CVs ranged between 2.0 and 5.6%, with the highest variation observed for β-amyloid 1-40. The reproducibility (inter-laboratory) CVs ranged between 2.1 and 6.5%, with the highest variation observed for β-amyloid 1-42. The clinical cutpoints for AD were determined to be 409 ng/L for total tau, 50.2 ng/L for pTau 181, 526 ng/L for β-amyloid 1-42, and 0.072 for the Aβ 1-42/Aβ 1-40 ratio. Conclusions Our results suggest that the LUMIPULSE G assays for the CSF AD biomarkers are fit for purpose in clinical laboratory practice. Further, they corroborate earlier presented reference limits for the biomarkers.