Pressure-assisted introduction of urine samples into a short capillary for electrophoretic separation with contactless conductivity and UV spectrometry detection

2015 ◽  
Vol 36 (16) ◽  
pp. 1962-1968 ◽  
Author(s):  
Anna Makrlíková ◽  
František Opekar ◽  
Petr Tůma
2007 ◽  
Vol 177 (4S) ◽  
pp. 295-295
Author(s):  
Michael Mullerad ◽  
Haleem J. Issaq ◽  
Alexander Kravtsov ◽  
Timothy Waybright ◽  
Brian Luke ◽  
...  

1991 ◽  
Vol 66 (04) ◽  
pp. 500-504 ◽  
Author(s):  
H Peretz ◽  
U Seligsohn ◽  
E Zwang ◽  
B S Coller ◽  
P J Newman

SummarySevere Glanzmann's thrombasthenia is relatively frequent in Iraqi-Jews and Arabs residing in Israel. We have recently described the mutations responsible for the disease in Iraqi-Jews – an 11 base pair deletion in exon 12 of the glycoprotein IIIa gene, and in Arabs – a 13 base pair deletion at the AG acceptor splice site of exon 4 on the glycoprotein IIb gene. In this communication we show that the Iraqi-Jewish mutation can be identified directly by polymerase chain reaction and gel electrophoresis. With specially designed oligonucleotide primers encompassing the mutation site, an 80 base pair segment amplified in healthy controls was clearly distinguished from the 69 base pair segment produced in patients. Patients from 11 unrelated Iraqi-Jewish families had the same mutation. The Arab mutation was identified by first amplifying a DNA segment consisting of 312 base pairs in controls and of 299 base pairs in patients, and then digestion by a restriction enzyme Stu-1, which recognizes a site that is absent in the mutant gene. In controls the 312 bp segment was digested into 235 and 77 bp fragments, while in patients there was no change in the size of the amplified 299 bp segment. The mutation was found in patients from 3 out of 5 unrelated Arab families. Both Iraqi-Jewish and Arab mutations were detectable in DNA extracted from blood and urine samples. The described simple methods of identifying the mutations should be useful for detection of the numerous potential carriers among the affected kindreds and for prenatal diagnosis using DNA extracted from chorionic villi samples.


1989 ◽  
Vol 121 (4) ◽  
pp. 513-519 ◽  
Author(s):  
Hiroshi Tomita ◽  
Masamichi Ogawa ◽  
Takashi Kamijo ◽  
Osamu Mori ◽  
Eiji Ishikawa ◽  
...  

Abstract. GH values were determined by a highly sensitive sandwich enzyme immunoassay in the 1st morning and/or 24-h accumulated urine samples in 94 children (short stature 70, including 14 with complete GH deficiency, 9 with partial GH deficiency, and 47 with GH-normal short stature; Turner's syndrome, 10, and simple obesity, 14). GH values were also determined in the 2nd to 4th urine samples taken on the same day together with the 1st morning urine in 5 of them. GH values in the 1st morning urine correlated significantly with those of the 24-h urine and with serum peak and mean GH values during nocturnal sleep as a physiological GH secretion test. The 2nd to 4th urines had lower GH concentrations than the 1st morning urine. The GH value of the 1st morning urine in complete GH deficiency was significantly lower than those in GH-normal short stature, partial GH deficiency and Turner's syndrome. However, no significant difference was detected in urinary GH values between complete GH deficiency and simple obesity. We conclude that 1st morning urinary GH estimation may be useful for differentiation of complete GH deficiency from other causes of short stature, but may be difficult for the distinction between complete GH deficiency and obesity with normal GH secretory ability.


1960 ◽  
Vol XXXIV (I) ◽  
pp. 45-50 ◽  
Author(s):  
J. L. Kalliomäki ◽  
Lauri Rauramo

ABSTRACT The authors have endeavoured to clarify the frequency of the hyperoestrogenismus syndrome in women with rheumatoid arthritis, aged 17–38 years, by means of clinical and cytologic studies, and by hormonal analyses. The material comprises 32 patients. Of these, 30 were suitable for cytologic observation. In 5 (17 %) of these 30 patients, the hyperoestrogenismus syndrome (17 %) may be considered definitely established. Aggravation of the joint symptoms in the pre-menstrual phase was reported by 41 % of the patients. Values for excretion of oestrogen exceeding 200 mouse units/24 hours were noted one week before menstrual bleeding in 8 of 19 women; the mean for oestrogen excretion was 268 mouse units/24 hours. Gonadotrophins were studied in the same urine samples, and the mean excretion was 22 mouse units/24 hours (range 7–65 m. u.). The excretion mean for 17-ketosteroids, simultaneously studied, was 9.1 mg/24 hours (range 2.3–18.0 mg). Side-finding in the material were made: incipient cervical cancer in one patient, ovarial tumour in one, and trichomoniasis in seven.


2017 ◽  
Vol 68 (2) ◽  
pp. 279-283
Author(s):  
Mihail Silviu Tudosie ◽  
Elena Truta ◽  
Ana Maria Davitoiu ◽  
Luminita Stanciulescu ◽  
George Jinescu ◽  
...  

During one year (september 2013 � september 2014), 50 children from the residential institution for children SOS Satele Copiilor Bucharest, where included in our research. The children were distributed in two groups: Group A which consisted of 25 children (12 girls, 13 boys) who were not diagnosed with attention deficit hyperactivity disorder (ADHD) and Group B which consisted of 25 children (14 boys, 11 girls) who were diagnosed with ADHD. Initially, the two groups were subjected at a psycho-diagnostic battery of tests, one of them being the Evaluating the Health State of children with ADHD questionnaire elaborated by us, particularly for this research, with the purpose of highlighting the direct link between the children health state and their ADHD symptoms. This study sought to determine the concentration of copper in urine samples from a group of children with ADHD and a group of normal children, to highlight the role of copper in the development of ADHD symptoms. Levels of copper concentration in urine samples from the two groups were processed by Student�s t-Test. Statistical analysis showed that the arithmetic averages of copper concentration in urine samples, of the two groups do not differ significantly, so copper may be causing ADHD symptoms occur. The copper content in urine samples has been determined using atomic absorption spectrometry with graphite furnace.


2020 ◽  
Vol 16 (5) ◽  
pp. 652-659
Author(s):  
Asiye A. Avan ◽  
Hayati Filik

Background: An Ionic Liquid-based based Dispersive Liquid-Liquid Microextraction (IL-DLLME) method was not applied to preconcentration and determination of bilirubin. Ionic Liquids (ILs) are new chemical compounds. In recent years, Ionic Liquids (ILs) have been employed as alternative solvents to toxic organic solvents. Due to these perfect properties, ILs have already been applied in many analytical extraction processes, presenting high extraction yield and selectivity for analytes. Methods: In this study, IL-DLLME was applied to biological samples (urine and serum) for the spectrophotometric detection of bilirubin. For bilirubin analysis, the full-color development was based on the reaction with periodate in the presence of hydrochloric acid. The high affinity of bilirubin for the ionic liquid phase gave extraction percentages above 98% in 0.3 M HCl solution. Results: Several IL-extraction parameters were optimized and room temperature ionic liquid 1-butyl- 1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide and ethanol were used as extraction and disperser solution. The linear range was found in the range of 0.5-6.0 μM (0.3-3.5 μg mL-1) and the limits of detection of the proposed method was 0.5 μM (0.3 μg mL-1). The proposed method was applied for the preconcentration and separation of trace bilirubin in real urine samples. Also, the recoveries for bilirubin in spiked biological samples (urine and serum) were found to be acceptable, between 95-102%. Conclusion: The proposed IL-DLLMEapproach was employed for the enrichment and determination of trace levels of bilirubin in urine samples using NaIO4 as an oxidizing agent and Uv-vis spectrophotometric detection. The periodate oxidation of bilirubin is rapid, effective, selective, and simple to perform. The method contains only HCl, NaOI4, and an anionic surfactant. The method may be useful for economizing in the consumption of reagents in bilirubin determining. The IL-DLLMEmethod ensures a high yield and has a low toxicity no skin sensitization, no mutagenicity and no ecotoxicity in an aquatic environment since only very low quantities of an IL is required. For full-color formation, no any extra auxiliary reagents are required. Besides, the IL-DLLME technique uses a low-cost instrument such as Uv-vis which is present in most of the medical laboratories.


Sign in / Sign up

Export Citation Format

Share Document