Biological monitoring of workers exposed to lead stearate

1990 ◽  
Vol 10 (1) ◽  
pp. 65-68 ◽  
Author(s):  
C. N. Ong ◽  
L. H. Chua ◽  
K. Teramoto
Author(s):  
G.F. Bastin ◽  
H.J.M. Heijligers

Among the ultra-light elements B, C, N, and O nitrogen is the most difficult element to deal with in the electron probe microanalyzer. This is mainly caused by the severe absorption that N-Kα radiation suffers in carbon which is abundantly present in the detection system (lead-stearate crystal, carbonaceous counter window). As a result the peak-to-background ratios for N-Kα measured with a conventional lead-stearate crystal can attain values well below unity in many binary nitrides . An additional complication can be caused by the presence of interfering higher-order reflections from the metal partner in the nitride specimen; notorious examples are elements such as Zr and Nb. In nitrides containing these elements is is virtually impossible to carry out an accurate background subtraction which becomes increasingly important with lower and lower peak-to-background ratios. The use of a synthetic multilayer crystal such as W/Si (2d-spacing 59.8 Å) can bring significant improvements in terms of both higher peak count rates as well as a strong suppression of higher-order reflections.


2017 ◽  
pp. 65-72
Author(s):  
Kudria M.Ya. ◽  
◽  
Lalymenko O.S. ◽  
Karachentsev Yu.I. ◽  
Zavhorodny I.V. ◽  
...  

Author(s):  
Anastasiya G. Khotuleva ◽  
Mariya S. Kozyreva

Introduction. The most susceptible to lead is the hematopoietic system of hematopoietic organs due to lead inhibition of heme and globin synthesis and cytotoxic effect on the membrane of Mature red blood cells. The aim of study was to evaluate the informative value of the study of erythrocyte and reticulocyte parameters determined on modern hematological analyzers in patients working in contact with lead during medical and biological monitoring. Materials and methods. 45 employees of the lead battery processing plant and 30 persons of control group were examined. The level of lead in the blood was determined by atomic absorption spectrometry, δ-ALA in the urine-by the reaction of pyrol formation with acetylacetone in terms of gram of creatinine, the study of hematological parameters was performed on a Sysmex HT-2000i analyzer. Statistical processing of the results was performed using the program STATISTICA 10.0. Results. Significant changes in erythrocytic (RDW) and reticulocytic (RET, IRF, LFR, MFR, HFR, RET-He) parameters, erythropoietin in workers in contact with lead compared to the control group, changes in MCV, MCH, RDW, RET indicators in the group working in dynamics after 2 years were revealed. Associations of hematological parameters with biomarkers of exposure and effect (lead level in blood and ALA in urine) were revealed. Conclusions. Assessment of erythrocyte (MCV, MCH, RDW) and reticulocyte parameters (RET% and their distribution by maturity) in dynamics during periodic medical examinations of workers in contact with lead allows us to detect the development of hematological disorders at early stages.


Author(s):  
L. V. Lukovnikova ◽  
G. I. Sidorin ◽  
L. A. Alikbaeva ◽  
A. V. Galochina

When examining the population exposed to organic and inorganic compounds of mercury, a comprehensive approach is proposed, including chemical monitoring of environmental objects, biological monitoring, clinical examination of persons exposed to mercury, identification of high-risk groups.


Sign in / Sign up

Export Citation Format

Share Document