Dynamic Response of Fluid and Wall Temperatures during Pressurized Discharge for Simultaneous, Time-Dependent Inlet Gas Temperature, Ambient Temperature, and/or Ambient Heat Flux

Author(s):  
V. S. Arpaci ◽  
J. A. Clark
Meccanica ◽  
2015 ◽  
Vol 51 (1) ◽  
pp. 139-154 ◽  
Author(s):  
J. N. Sharma ◽  
P. K. Sharma ◽  
Krishna C. Mishra

2021 ◽  
pp. 146808742110072
Author(s):  
Karri Keskinen ◽  
Walter Vera-Tudela ◽  
Yuri M Wright ◽  
Konstantinos Boulouchos

Combustion chamber wall heat transfer is a major contributor to efficiency losses in diesel engines. In this context, thermal swing materials (adapting to the surrounding gas temperature) have been pinpointed as a promising mitigative solution. In this study, experiments are carried out in a high-pressure/high-temperature vessel to (a) characterise the wall heat transfer process ensuing from wall impingement of a combusting fuel spray, and (b) evaluate insulative improvements provided by a coating that promotes thermal swing. The baseline experimental condition resembles that of Spray A from the Engine Combustion Network, while additional variations are generated by modifying the ambient temperature as well as the injection pressure and duration. Wall heat transfer and wall temperature measurements are time-resolved and accompanied by concurrent high-speed imaging of natural luminosity. An investigation with an uncoated wall is carried out with several sensor locations around the stagnation point, elucidating sensor-to-sensor variability and setup symmetry. Surface heat flux follows three phases: (i) an initial peak, (ii) a slightly lower plateau dependent on the injection duration, and (iii) a slow decline. In addition to the uncoated reference case, the investigation involves a coating made of porous zirconia, an established thermal swing material. With a coated setup, the projection of surface quantities (heat flux and temperature) from the immersed measurement location requires additional numerical analysis of conjugate heat transfer. Starting from the traces measured beneath the coating, the surface quantities are obtained by solving a one-dimensional inverse heat transfer problem. The present measurements are complemented by CFD simulations supplemented with recent rough-wall models. The surface roughness of the coated specimen is indicated to have a significant impact on the wall heat flux, offsetting the expected benefit from the thermal swing material.


1980 ◽  
Vol 23 (8) ◽  
pp. 1532 ◽  
Author(s):  
H. Schamel ◽  
Ch. Sack
Keyword(s):  

2021 ◽  
Author(s):  
Richard Blythman ◽  
Sajad Alimohammadi ◽  
Nicholas Jeffers ◽  
Darina B. Murray ◽  
Tim Persoons

Abstract While numerous applied studies have successfully demonstrated the feasibility of unsteady cooling solutions, a consensus has yet to be reached on the local instantaneous conditions that result in heat transfer enhancement. The current work aims to experimentally validate a recent analytical solution (on a local time-dependent basis) for the common flow condition of a fully-developed incompressible pulsating flow in a uniformly-heated vessel. The experimental setup is found to approximate the ideal constant heat flux boundary condition well, especially for the decoupled unsteady scenario where the amplitude of the most significant secondary contributions (capacitance and lateral conduction) amounts to 1.2% and 0.2% of the generated heat flux, respectively. Overall, the experimental measurements for temperature and heat flux oscillations are found to coincide well with a recent analytical solution to the energy equation by the authors. Furthermore, local time-dependent heat flux enhancements and degradations are observed to be qualitatively similar to those of wall shear stress from a previous study, suggesting that the thermal performance is indeed influenced by hydrodynamic behaviour.


2017 ◽  
Author(s):  
Daniel Madrzykowski ◽  

The goal of this study was to review the available literature to develop a quantitative description of the thermal conditions firefighters and their equipment are exposed to in a structural fire environment. The thermal exposure from the modern fire environment was characterized through the review of fire research studies and fire-ground incidents that provided insight and data to develop a range of quantification. This information was compared with existing standards for firefighting protective equipment to generate a sense of the gap between known information and the need for improved understanding. The comparison of fire conditions with the thermal performance requirements of firefighter protective gear and equipment demonstrates that a fire in a compartment can generate conditions that can fail the equipment that a firefighter wears or uses. The review pointed out the following: 1. The accepted pairing of gas temperature ranges with a corresponding range of heat fluxes does not reflect all compartment fire conditions. There are cases in which the heat flux exceeds the hazard level of the surrounding gas temperature. 2. Thermal conditions can change within seconds. Experimental conditions and incidents were identified in which firefighters would be operating in thermal conditions that were safe for operation based on the temperature and heat flux, but then due to a change in the environment the firefighters would be exposed to conditions that could exceed the protective capabilities of their PPE. 3. Gas velocity is not explicitly considered within the thermal performance requirements. Clothing and equipment tested with a hot air circulating (convection) oven are exposed to gas velocities that measure approximately 1.5 m/s (3 mph). In contrast, the convected hot gas flows within a structure fire could range from 2.3 m/s (5 mph) to 7.0 m/s (15 mph). In cases where the firefighter or equipment would be located in the exhaust portion of a flow path, while operating above the level of the fire, the hot gas velocity could be even higher. This increased hot gas velocity would serve to increase the convective heat transfer rate to the equipment and the firefighter, thereby reducing the safe operating time within the structure. 4. Based on the limited data available, it appears currently available protective clothing enables firefighters to routinely operate in conditions above and beyond the "routine" conditions measured in the fire-ground exposure studies conducted during the 1970s. The fire service and fire standards communities could benefit from an improved understanding of: • real world fire-ground conditions, including temperatures, heat flux, pressure, and chemical exposures; • the impact of convection on the thermal resistance capabilities of firefighting PPE and equipment; and • the benefits of balancing the thermal exposures (thermal performance requirements) across different components of firefighter protective clothing and safety equipment. Because it is unlikely due to trade offs in weight, breathe-ability, usability, cost, etc., that fireproof PPE and equipment will ever be a reality, fire officers and fire chiefs need to consider the capabilities of the protection that their firefighters have when determining fire attack strategies and tactics to ensure that the PPE and equipment is kept within its design operating environment, and that the safety buffer it provides is maintained.


1999 ◽  
Author(s):  
Sungsoo Na ◽  
Liviu Librescu

Abstract A study of the dynamical behavior of aircraft wings modeled as doubly-tapered thin-walled beams, made from advanced anisotropic composite materials, and incorporating a number of non-classical effects such as transverse shear, and warping inhibition is presented. The supplied numerical results illustrate the effects played by the taper ratio, anisotropy of constituent materials, transverse shear flexibility, and warping inhibition on free vibration and dynamic response to time-dependent external excitations. Although considered for aircraft wings, this analysis and results can be also applied to a large number of structures such as helicopter blades, robotic manipulator arms, space booms, tall cantilever chimneys, etc.


2021 ◽  
Vol 11 (17) ◽  
pp. 8068
Author(s):  
Anna Dąbrowska ◽  
Monika Kobus ◽  
Bartosz Pękosławski ◽  
Łukasz Starzak

In recent times, more and more workers are exposed to thermal stress due to climate changes and increased ambient temperature. Demanding physical activities and the use of protective clothing are additional sources of thermal load for workers. Therefore, recent research has focused on the development of protective clothing with a cooling function. Phase change materials, air or liquid, were mainly used for this purpose; only a few publications were concerned the use of thermoelectric modules. This publication analyzes the influence of such factors as supplied current, ambient temperature, and the type of heat sink on the amount of heat flux transferred by a thermoelectric cooler (TEC) and the electric power consumed by it. In the course of laboratory tests, a flexible thermoelectric module and three heat sink variants were tested. For this purpose, a polymer TEGway heat sink, a metal one, and a self-made one based on a superabsorbent were used. The research showed that at a temperature of 30 °C and above, the amount of the heat flux transferred by a TEC with a total area of 58 cm2, and an active area of 10 cm2 should be expected to be from 1 W to 1.5 W. An increase in ambient temperature from 20 to 35 °C caused a significant reduction in the heat flux by about 1 W. The results obtained indicated that the type of heat sink affects the heat flux drawn by the TEC to a statistically significant extent. The heat sink using the evaporation effect turned out to be the most efficient.


Sign in / Sign up