Motion Analysis and Fabrication of a Low-Cost Thruster Using Magnetic Coupling

Author(s):  
Ngoc-Huy Tran ◽  
Thanh-Hai Chau ◽  
Thien-Phuong Ton
2019 ◽  
Vol 13 (3) ◽  
Author(s):  
Nicolo Garbin ◽  
Patrick Doyle ◽  
Byron Smith ◽  
Jesse G. Taylor ◽  
Mubashir H. Khan ◽  
...  

This paper presents the design, fabrication, and experimental validation of a novel low-cost implantable pump for the treatment of refractory ascites (RA) based on local magnetic actuation (LMA). A reciprocating positive displacement pump displaces liquid unidirectionally through magnetic coupling with a magnetic controller placed on the outside of the patient's body. The proposed solution is intuitive to use given an alignment algorithm that exploits externally placed magnetic field sensors (MFS). The implantable device has a catheter-like shape, is electronic free (no on-board battery), has low fabrication cost (<8 USD), and is able to generate a flow-rate of 3.65 L/h while effectively pumping fluids with various viscosity (1–5.5 cP). RA is commonly treated via costly paracentesis or invasive surgical placement of a transjugular portosystemic shunt (TIPS). The proposed solution can be implanted with minimally invasive techniques and can be used on a daily basis to drain a set amount of liquid, without requiring recurrent hospital visits.


Sensors ◽  
2020 ◽  
Vol 20 (5) ◽  
pp. 1525
Author(s):  
Natiely Hernández Sebastián ◽  
Noé Villa Villaseñor ◽  
Francisco-Javier Renero-Carrillo ◽  
Daniela Díaz Alonso ◽  
Wilfrido Calleja Arriaga

In this paper, an alternative strategy for the design of a bidirectional inductive power transfer (IPT) module, intended for the continuous monitoring of cardiac pressure, is presented. This new integrated implantable medical device (IMD) was designed including a precise ventricular pressure sensor, where the available implanting room is restricted to a 1.8 × 1.8 cm2 area. This work considers a robust magnetic coupling between an external reading coil and the implantable module: a three-dimensional inductor and a touch mode capacitive pressure sensor (TMCPS) set. In this approach, the coupling modules were modelled as RCL circuits tuned at a 13.56 MHz frequency. The analytical design was validated by means of Comsol Multiphysics, CoventorWare, and ANSYS HFSS software tools. A power transmission efficiency (PTE) of 94% was achieved through a 3.5 cm-thick biological tissue, based on high magnitudes for the inductance (L) and quality factor (Q) components. A specific absorption rate (SAR) of less than 1.6 W/Kg was attained, which suggests that this IPT system can be implemented in a safe way, according to IEEE C95.1 safety guidelines. The set of inductor and capacitor integrated arrays were designed over a very thin polyimide film, where the 3D coil was 18 mm in diameter and approximately 50% reduced in size, considering any conventional counterpart. Finally, this new approach for the IMD was under development using low-cost thin film manufacturing technologies for flexible electronics. Meanwhile, as an alternative test, this novel system was fabricated using a discrete printed circuit board (PCB) approach, where preliminary electromagnetic characterization demonstrates the viability of this bidirectional IPT design.


2016 ◽  
Vol 26 (12) ◽  
pp. 996-998 ◽  
Author(s):  
Hossein Saghlatoon ◽  
Rashid Mirzavand Boroujeni ◽  
Mohammad Mahdi Honari ◽  
Pedram Mousavi

2013 ◽  
Vol 284-287 ◽  
pp. 1996-2000 ◽  
Author(s):  
Hai Trieu Pham ◽  
Jung Ja Kim ◽  
Yong Gwan Won

Many motion analysis systems which have been introduced in the past few years are currently receiving interests from researchers and developers due to their usefulness and wide application capability in the future. However, many of those systems meet with difficulties for the real applications because of high cost for the implementation and less accuracy. This paper introduces a new 3D motion analysis system which can be implemented at a lower cost and acceptable accuracy for various applications. The key component of our new system is the use of the MSK (Microsoft Kinect) sensor system which is equipped with both visual camera and infrared camera. It can provide the color image, the 3D depth image and the 3D skeleton data without wearing any marker device on the human body while it can provide acceptable accuracy in 3D motion trace at low cost. Our system can be exploited for a base framework for various 3D motion-based applications such as physical rehabilitation support, sport motion analysis and biomechanical applications.


Sign in / Sign up

Export Citation Format

Share Document