Low-Cost Inkjet Printed Passive Booster for Increasing the Magnetic Coupling in Proximity of Metal Object for NFC Systems

2016 ◽  
Vol 26 (12) ◽  
pp. 996-998 ◽  
Author(s):  
Hossein Saghlatoon ◽  
Rashid Mirzavand Boroujeni ◽  
Mohammad Mahdi Honari ◽  
Pedram Mousavi
2019 ◽  
Vol 13 (3) ◽  
Author(s):  
Nicolo Garbin ◽  
Patrick Doyle ◽  
Byron Smith ◽  
Jesse G. Taylor ◽  
Mubashir H. Khan ◽  
...  

This paper presents the design, fabrication, and experimental validation of a novel low-cost implantable pump for the treatment of refractory ascites (RA) based on local magnetic actuation (LMA). A reciprocating positive displacement pump displaces liquid unidirectionally through magnetic coupling with a magnetic controller placed on the outside of the patient's body. The proposed solution is intuitive to use given an alignment algorithm that exploits externally placed magnetic field sensors (MFS). The implantable device has a catheter-like shape, is electronic free (no on-board battery), has low fabrication cost (<8 USD), and is able to generate a flow-rate of 3.65 L/h while effectively pumping fluids with various viscosity (1–5.5 cP). RA is commonly treated via costly paracentesis or invasive surgical placement of a transjugular portosystemic shunt (TIPS). The proposed solution can be implanted with minimally invasive techniques and can be used on a daily basis to drain a set amount of liquid, without requiring recurrent hospital visits.


Sensors ◽  
2020 ◽  
Vol 20 (5) ◽  
pp. 1525
Author(s):  
Natiely Hernández Sebastián ◽  
Noé Villa Villaseñor ◽  
Francisco-Javier Renero-Carrillo ◽  
Daniela Díaz Alonso ◽  
Wilfrido Calleja Arriaga

In this paper, an alternative strategy for the design of a bidirectional inductive power transfer (IPT) module, intended for the continuous monitoring of cardiac pressure, is presented. This new integrated implantable medical device (IMD) was designed including a precise ventricular pressure sensor, where the available implanting room is restricted to a 1.8 × 1.8 cm2 area. This work considers a robust magnetic coupling between an external reading coil and the implantable module: a three-dimensional inductor and a touch mode capacitive pressure sensor (TMCPS) set. In this approach, the coupling modules were modelled as RCL circuits tuned at a 13.56 MHz frequency. The analytical design was validated by means of Comsol Multiphysics, CoventorWare, and ANSYS HFSS software tools. A power transmission efficiency (PTE) of 94% was achieved through a 3.5 cm-thick biological tissue, based on high magnitudes for the inductance (L) and quality factor (Q) components. A specific absorption rate (SAR) of less than 1.6 W/Kg was attained, which suggests that this IPT system can be implemented in a safe way, according to IEEE C95.1 safety guidelines. The set of inductor and capacitor integrated arrays were designed over a very thin polyimide film, where the 3D coil was 18 mm in diameter and approximately 50% reduced in size, considering any conventional counterpart. Finally, this new approach for the IMD was under development using low-cost thin film manufacturing technologies for flexible electronics. Meanwhile, as an alternative test, this novel system was fabricated using a discrete printed circuit board (PCB) approach, where preliminary electromagnetic characterization demonstrates the viability of this bidirectional IPT design.


2014 ◽  
Vol 889-890 ◽  
pp. 703-706
Author(s):  
Xiang Fei Meng ◽  
Zhi Chao Li

It uses MSP430F2274, the ultra low power microcontroller, as the control core of short circuit detection device, through the accurate measurement of low voltage circuit breaker load side of the main wiring of insulation resistance value and the interphase insulation resistance value, outputting high voltage startup sound and light alarm device, and then accomplish the open circuit fault detection. Testing power supply is the use of magnetic coupling resonance principle, from the main power grid electrical insulation for short circuit detection device. The device has the advantages of low cost, small volume, good safety, good detection effect, and can be embedded in use in low voltage circuit breaker.


2016 ◽  
Vol 18 (27) ◽  
pp. 18365-18380 ◽  
Author(s):  
Lorenzo Tenti ◽  
Daniel Maynau ◽  
Celestino Angeli ◽  
Carmen J. Calzado

A new perturbative + variational strategy: a low-cost, quantitative and rational evaluation of the magnetic coupling constant in complex systems.


Author(s):  
Y. L. Chen ◽  
S. Fujlshiro

Metastable beta titanium alloys have been known to have numerous advantages such as cold formability, high strength, good fracture resistance, deep hardenability, and cost effectiveness. Very high strength is obtainable by precipitation of the hexagonal alpha phase in a bcc beta matrix in these alloys. Precipitation hardening in the metastable beta alloys may also result from the formation of transition phases such as omega phase. Ti-15-3 (Ti-15V- 3Cr-3Al-3Sn) has been developed recently by TIMET and USAF for low cost sheet metal applications. The purpose of the present study was to examine the aging characteristics in this alloy.The composition of the as-received material is: 14.7 V, 3.14 Cr, 3.05 Al, 2.26 Sn, and 0.145 Fe. The beta transus temperature as determined by optical metallographic method was about 770°C. Specimen coupons were prepared from a mill-annealed 1.2 mm thick sheet, and solution treated at 827°C for 2 hr in argon, then water quenched. Aging was also done in argon at temperatures ranging from 316 to 616°C for various times.


Author(s):  
J. D. Muzzy ◽  
R. D. Hester ◽  
J. L. Hubbard

Polyethylene is one of the most important plastics produced today because of its good physical properties, ease of fabrication and low cost. Studies to improve the properties of polyethylene are leading to an understanding of its crystalline morphology. Polyethylene crystallized by evaporation from dilute solutions consists of thin crystals called lamellae. The polyethylene molecules are parallel to the thickness of the lamellae and are folded since the thickness of the lamellae is much less than the molecular length. This lamellar texture persists in less perfect form in polyethylene crystallized from the melt.Morphological studies of melt crystallized polyethylene have been limited due to the difficulty of isolating the microstructure from the bulk specimen without destroying or deforming it.


Author(s):  
J. Temple Black

In ultramicrotomy, the two basic tool materials are glass and diamond. Glass because of its low cost and ease of manufacture of the knife itself is still widely used despite the superiority of diamond knives in many applications. Both kinds of knives produce plastic deformation in the microtomed section due to the nature of the cutting process and microscopic chips in the edge of the knife. Because glass has no well defined slip planes in its structure (it's an amorphous material), it is very strong and essentially never fails in compression. However, surface flaws produce stress concentrations which reduce the strength of glass to 10,000 to 20,000 psi from its theoretical or flaw free values of 1 to 2 million psi. While the microchips in the edge of the glass or diamond knife are generally too small to be observed in the SEM, the second common type of defect can be identified. This is the striations (also termed the check marks or feathers) which are always present over the entire edge of a glass knife regardless of whether or not they are visable under optical inspection. These steps in the cutting edge can be observed in the SEM by proper preparation of carefully broken knives and orientation of the knife, with respect to the scanning beam.


Sign in / Sign up

Export Citation Format

Share Document