Minkowski’s Proper Time and the Status of the Clock Hypothesis

2010 ◽  
pp. 159-179 ◽  
Author(s):  
Richard T. W. Arthur
Author(s):  
Mario Bacelar Valente

The clock hypothesis is taken to be an assumption independent of special relativity necessary to describe accelerated clocks. This enables to equate the time read off by a clock to the proper time. Here, it is considered a physical system–the light clock–proposed by Marzke and Wheeler. Recently, Fletcher proved a theorem that shows that a sufficiently small light clock has a time reading that approximates to an arbitrary degree the proper time. The clock hypothesis is not necessary to arrive at this result. Here, one explores the consequences of this regarding the status of the clock hypothesis.


Author(s):  
L.J. Chen ◽  
Y.F. Hsieh

One measure of the maturity of a device technology is the ease and reliability of applying contact metallurgy. Compared to metal contact of silicon, the status of GaAs metallization is still at its primitive stage. With the advent of GaAs MESFET and integrated circuits, very stringent requirements were placed on their metal contacts. During the past few years, extensive researches have been conducted in the area of Au-Ge-Ni in order to lower contact resistances and improve uniformity. In this paper, we report the results of TEM study of interfacial reactions between Ni and GaAs as part of the attempt to understand the role of nickel in Au-Ge-Ni contact of GaAs.N-type, Si-doped, (001) oriented GaAs wafers, 15 mil in thickness, were grown by gradient-freeze method. Nickel thin films, 300Å in thickness, were e-gun deposited on GaAs wafers. The samples were then annealed in dry N2 in a 3-zone diffusion furnace at temperatures 200°C - 600°C for 5-180 minutes. Thin foils for TEM examinations were prepared by chemical polishing from the GaA.s side. TEM investigations were performed with JE0L- 100B and JE0L-200CX electron microscopes.


Author(s):  
Frank J. Longo

Measurement of the egg's electrical activity, the fertilization potential or the activation current (in voltage clamped eggs), provides a means of detecting the earliest perceivable response of the egg to the fertilizing sperm. By using the electrical physiological record as a “real time” indicator of the instant of electrical continuity between the gametes, eggs can be inseminated with sperm at lower, more physiological densities, thereby assuring that only one sperm interacts with the egg. Integrating techniques of intracellular electrophysiological recording, video-imaging, and electron microscopy, we are able to identify the fertilizing sperm precisely and correlate the status of gamete organelles with the first indication (fertilization potential/activation current) of the egg's response to the attached sperm. Hence, this integrated system provides improved temporal and spatial resolution of morphological changes at the site of gamete interaction, under a variety of experimental conditions. Using these integrated techniques, we have investigated when sperm-egg plasma membrane fusion occurs in sea urchins with respect to the onset of the egg's change in electrical activity.


2000 ◽  
Vol 64 (11) ◽  
pp. 772-774 ◽  
Author(s):  
JG Odom ◽  
PL Beemsterboer ◽  
TD Pate ◽  
NK Haden

2003 ◽  
Vol 8 (4) ◽  
pp. 4-5
Author(s):  
Christopher R. Brigham ◽  
James B. Talmage

Abstract Permanent impairment cannot be assessed until the patient is at maximum medical improvement (MMI), but the proper time to test following carpal tunnel release often is not clear. The AMA Guides to the Evaluation of Permanent Impairment (AMA Guides) states: “Factors affecting nerve recovery in compression lesions include nerve fiber pathology, level of injury, duration of injury, and status of end organs,” but age is not prognostic. The AMA Guides clarifies: “High axonotmesis lesions may take 1 to 2 years for maximum recovery, whereas even lesions at the wrist may take 6 to 9 months for maximal recovery of nerve function.” The authors review 3 studies that followed patients’ long-term recovery of hand function after open carpal tunnel release surgery and found that estimates of MMI ranged from 25 weeks to 24 months (for “significant improvement”) to 18 to 24 months. The authors suggest that if the early results of surgery suggest a patient's improvement in the activities of daily living (ADL) and an examination shows few or no symptoms, the result can be assessed early. If major symptoms and ADL problems persist, the examiner should wait at least 6 to 12 months, until symptoms appear to stop improving. A patient with carpal tunnel syndrome who declines a release can be rated for impairment, and, as appropriate, the physician may wish to make a written note of this in the medical evaluation report.


2002 ◽  
Vol 110 (2) ◽  
pp. 9-15 ◽  
Author(s):  
W Freedman
Keyword(s):  

1998 ◽  
Vol 14 (1) ◽  
pp. 62-70 ◽  
Author(s):  
Richard H. Dana

This paper describes the status of multicultural assessment training, research, and practice in the United States. Racism, politicization of issues, and demands for equity in assessment of psychopathology and personality description have created a climate of controversy. Some sources of bias provide an introduction to major assessment issues including service delivery, moderator variables, modifications of standard tests, development of culture-specific tests, personality theory and cultural/racial identity description, cultural formulations for psychiatric diagnosis, and use of findings, particularly in therapeutic assessment. An assessment-intervention model summarizes this paper and suggests dimensions that compel practitioners to ask questions meriting research attention and providing avenues for developments of culturally competent practice.


1962 ◽  
Vol 7 (4) ◽  
pp. 156-156
Author(s):  
C. SHAGASS

1990 ◽  
Vol 35 (10) ◽  
pp. 982-983
Author(s):  
Gail M. Williamson
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document