An Enhanced Region-Based Model for Segmentation Images with Intensity Inhomogeneity

Author(s):  
Haiping Yu ◽  
Xiaoli Lin
2016 ◽  
Vol 2016 ◽  
pp. 1-10
Author(s):  
Yunjie Chen ◽  
Tianming Zhan ◽  
Ji Zhang ◽  
Hongyuan Wang

We propose a novel segmentation method based on regional and nonlocal information to overcome the impact of image intensity inhomogeneities and noise in human brain magnetic resonance images. With the consideration of the spatial distribution of different tissues in brain images, our method does not need preestimation or precorrection procedures for intensity inhomogeneities and noise. A nonlocal information based Gaussian mixture model (NGMM) is proposed to reduce the effect of noise. To reduce the effect of intensity inhomogeneity, the multigrid nonlocal Gaussian mixture model (MNGMM) is proposed to segment brain MR images in each nonoverlapping multigrid generated by using a new multigrid generation method. Therefore the proposed model can simultaneously overcome the impact of noise and intensity inhomogeneity and automatically classify 2D and 3D MR data into tissues of white matter, gray matter, and cerebral spinal fluid. To maintain the statistical reliability and spatial continuity of the segmentation, a fusion strategy is adopted to integrate the clustering results from different grid. The experiments on synthetic and clinical brain MR images demonstrate the superior performance of the proposed model comparing with several state-of-the-art algorithms.


2014 ◽  
Vol 513-517 ◽  
pp. 3463-3467
Author(s):  
Li Fen Zhou ◽  
Chang Xu Cai

The Chan-Vese (C-V) active contour model has low computational complexity, initialization and insensitive to noise advantagesand utilizes global region information of images, so it is difficult to handle images with intensity inhomogeneity. The Local binary fitting (LBF) model based on local region information has its certain advantages in mages segmentation of weak boundary or uneven greay.but , the segmentation results are very sensitive to the initial contours, In order to address this problem, this paper proposes a new active contour model with a partial differential equation, which integrates both global and local region information. Experimental results show that it has a distinctive advantage over C-V model for images with intensity inhomogeneity, and it is more efficient than LBF.


2017 ◽  
Vol 12 (4) ◽  
pp. 791-798 ◽  
Author(s):  
Hui Liu ◽  
Pinpin Tang ◽  
Dongmei Guo ◽  
HaiXia Liu ◽  
Yuanjie Zheng ◽  
...  

IEEE Access ◽  
2018 ◽  
Vol 6 ◽  
pp. 54224-54240 ◽  
Author(s):  
Qing Cai ◽  
Huiying Liu ◽  
Yiming Qian ◽  
Jing Li ◽  
Xiaojun Duan ◽  
...  

2014 ◽  
Vol E97.D (11) ◽  
pp. 2974-2978 ◽  
Author(s):  
Haoqi XIONG ◽  
Jingjing GAO ◽  
Chongjin ZHU ◽  
Yanling LI ◽  
Shu ZHANG ◽  
...  

2018 ◽  
Vol 27 (8) ◽  
pp. 3729-3738 ◽  
Author(s):  
Haider Ali ◽  
Lavdie Rada ◽  
Noor Badshah

2021 ◽  
pp. 1-12
Author(s):  
Lin Wu ◽  
Tian He ◽  
Jie Yu ◽  
Hang Liu ◽  
Shuang Zhang ◽  
...  

BACKGROUND: Addressing intensity inhomogeneity is critical in magnetic resonance imaging (MRI) because associated errors can adversely affect post-processing and quantitative analysis of images (i.e., segmentation, registration, etc.), as well as the accuracy of clinical diagnosis. Although several prior methods have been proposed to eliminate or correct intensity inhomogeneity, some significant disadvantages have remained, including alteration of tissue contrast, poor reliability and robustness of algorithms, and prolonged acquisition time. OBJECTIVE: In this study, we propose an intensity inhomogeneity correction method based on volume and surface coils simultaneous reception (VSSR). METHODS: The VSSR method comprises of two major steps: 1) simultaneous image acquisition from both volume and surface coils and 2) denoising of volume coil images and polynomial surface fitting of bias field. Extensive in vivo experiments were performed considering various anatomical structures, acquisition sequences, imaging resolutions, and orientations. In terms of correction performance, the proposed VSSR method was comparatively evaluated against several popular methods, including multiplicative intrinsic component optimization and improved nonparametric nonuniform intensity normalization bias correction methods. RESULTS: Experimental results show that VSSR is more robust and reliable and does not require prolonged acquisition time with the volume coil. CONCLUSION: The VSSR may be considered suitable for general implementation.


Sign in / Sign up

Export Citation Format

Share Document