Non-contact Detection of Vital Signs via a UWB Radar Sensor

Author(s):  
Zhenzhen Duan ◽  
Yang Zhang ◽  
Jian Zhang ◽  
Jing Liang
IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 36888-36895 ◽  
Author(s):  
Zhenzhen Duan ◽  
Jing Liang

Electronics ◽  
2019 ◽  
Vol 8 (8) ◽  
pp. 855 ◽  
Author(s):  
Park ◽  
Jeong ◽  
Lee ◽  
Oh ◽  
Yang

The authors wish to make the following corrections to the published paper [...]


2021 ◽  
pp. 1-1
Author(s):  
Yuying Zhu ◽  
Shuning Zhang ◽  
Xiaoxiong Li ◽  
Huichang Zhao ◽  
Lingzhi Zhu ◽  
...  

Sensors ◽  
2020 ◽  
Vol 20 (12) ◽  
pp. 3396
Author(s):  
Fatima Sekak ◽  
Kawtar Zerhouni ◽  
Fouzia Elbahhar ◽  
Madjid Haddad ◽  
Christophe Loyez ◽  
...  

Non-contact detection and estimation of vital signs such as respiratory and cardiac frequencies is a powerful tool for surveillance applications. In particular, the continuous wave bio-radar has been widely investigated to determine the physiological parameters in a non-contact manner. Since the RF-reflected signal from the human body is corrupted by noise and random body movements, traditional Fourier analysis fails to detect the heart and breathing frequencies. In this effort, cyclostationary analysis has been used to improve the radar performance for non-invasive measurement of respiratory rate and heart rate. However, the preliminary works focus only on one frequency and do not include the impact of attenuation and random movement of the body in the analysis. Hence in this paper, we evaluate the impact of distance and noise on the cyclic features of the reflected signal. Furthermore, we explore the assessment of second order cyclostationary signal processing performance by developing the cyclic mean, the conjugate cyclic autocorrelation and the cyclic cumulant. In addition, the analysis is carried out using a reduced number of samples to reduce the response time. Implementation of the cyclostationary technique using a bi-static radar configuration at 2.5 GHz is shown as an example to demonstrate the proposed approach.


Sensors ◽  
2019 ◽  
Vol 19 (14) ◽  
pp. 3085 ◽  
Author(s):  
Sandra Costanzo

Non-contact wireless sensing approaches have emerged in recent years, in order to enable novel enhanced developments in the framework of healthcare and biomedical scenarios. One of these technologically advanced solutions is given by software-defined radar platforms, a low-cost radar implementation, where all operations are implemented and easily changed via software. In the present paper, a software-defined radar implementation with Doppler elaboration features is presented, to be applied for the non-contact monitoring of human respiration signals. A quadrature receiver I/Q (In-phase/Quadrature) architecture is adopted in order to overcome the critical issues related to the occurrences of null detection points, while the phase-locked loop components included in the software defined radio transceiver are successfully exploited to guarantee the phase correlation between I/Q signal components. The proposed approach leads to a compact, low-cost, and flexible radar solution, whose application abilities may be simply changed via software, with no need for hardware modifications. Experimental results on a human target are discussed so as to demonstrate the feasibility of the proposed approach for vital signs detection.