Numerical Study on the Structural Integrity of Built-up Cold-Formed Steel Battened Columns

Author(s):  
M. Adil Dar ◽  
Dipti Ranjan Sahoo ◽  
Arvind K. Jain
2018 ◽  
Vol 65 ◽  
pp. 08010
Author(s):  
Je Chenn Gan ◽  
Jee Hock Lim ◽  
Siong Kang Lim ◽  
Horng Sheng Lin

Applications of Cold-Formed Steel (CFS) are widely used in buildings, machinery and etc. Many researchers began the research of CFS as a roof truss system. It is required to increase the knowledge of the configurations of CFS roof trusses due to the uncertainty of the structural failures regarding the materials and rigidity of joints. The objective of this research is to investigate the effect of heel plate length to the ultimate load capacity of CFS roof truss system. Three different lengths of heel plate specimens were fabricated and subjected to concentrated loads until failure. The highest ultimate capacity for the experiment was 30 kN. The results showed that the increment of the length of the heel plate had slightly increased the ultimate capacity and strain. The increment of the length of the heel plate had increased the deflection of the bottom chords but decreased the deflection of the top chords. Local buckling of top chords adjacent to the heel plate was the primary failure mode for all the heel plate specimens.


Author(s):  
Joseph E. D. Hess

Impulsively loaded pressure vessels are often closed using a bolted joint configured in a double staggered row pattern. The bolted joint design must maintain the placement of the vessel opening covers to support the structural integrity of the shell and also provide the necessary preload of sealing surfaces for leak prevention. Good design practice suggests configuring tensile loaded bolted joints with a double rows pattern in order to minimize prying against the bolt head induced by localized moments. Double bolt row patterns allow moments induced by load offsets to be reacted through contact of the faying surfaces of the bolted members and if separation occurs by differential axial loading of the two bolt rows. This acts to reduce direct prying of the mated members against the bolt heads. Material cost and operational time savings could be realized if a single bolt row design with acceptable performance was implemented. In this paper a detailed finite element model is described and calculation results are presented for two vessel configurations subjected to an impulsive load; a double staggered 64 bolt pattern and a single row 32 bolt pattern. Finite element results are compared to each other and to the rules of ASME Code Case 2564 in Section VIII, Division 3. Special attention is given to the loading induced in the bolts and to the relative deflection of faying surfaces containing seals. It will be shown that reducing the bolt count per opening from 64 to 32 results in increased peak response of the bolts, seal opening gaps, and shell. Nonetheless a single row bolt pattern does appear feasible and within the bounds of the Code Case.


2021 ◽  
Vol 2021 ◽  
pp. 1-22
Author(s):  
Xingyou Yao

The objective of this paper is to investigate the buckling behavior and design method of the ultimate strength for the cold-formed steel (CFS) built-up I-sectional columns under axial compression which failed in distortional buckling and interactive buckling. A total of 56 CFS built-up I-sectional columns subjected to axial compression were tested, and the different buckling modes and ultimate strengths were analyzed in detail by varying the thickness, the length, the spacing of screws, the end fastener group, and the cross-sectional dimensions of CFS built-up I-sectional columns. It was shown in the test that noticeable interaction of local and distortional buckling or interaction of local, distortional, and global buckling was observed for the built-up I-sectional columns with different lengths and cross-sectional dimensions. A finite element model (FEM) was developed and validated with experimental results. A further parametric study has been conducted including different cross sections and slenderness ratios for the built-up I-sectional columns. The load-carrying capacities obtained from the experimental and numerical study were used to investigate the feasibility of the current direct strength method (DSM) when DSM was applied to CFS built-up I-sectional columns. The comparison results showed that the current DSM is not safe for CFS built-up columns failed in distortional buckling and interactive buckling. Therefore, the improved design formulas were proposed, and their accuracy was verified by using finite element analysis (FEA) and experimental results of CFS built-up I-sectional columns subjected to axial compression.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Ruben Pellicer-Guridi ◽  
Michael W. Vogel ◽  
Viktor Vegh ◽  
Jiasheng Su ◽  
Matthew S. Rosen ◽  
...  

Abstract Dynamically adjustable permanent magnet arrays have been proposed to generate switchable magnetic fields for pre-polarisation in Ultra-Low Field magnetic resonance imaging. However, the optimal switching dynamics of the pre-polarisation magnetic field as well as the energy requirements, mechanical forces and stresses during switching of the pre-polarisation field have not been evaluated. We analysed these requirements numerically and estimated the magnetic resonance signal strength and image quality for two practical switching modes in an instrument suitable for scanning the human head. Von Mises stress analysis showed that although magnetic forces were significantly higher for two specific rungs, the structural integrity of magnet rungs would not be compromised. Our simulations suggest that a significantly higher signal yield is obtained by switching off the pre-polarisation field with the angular velocity in each rung dependent on its location.


2017 ◽  
Vol 23 (4) ◽  
pp. 385-397
Author(s):  
Mohammed H. Serror ◽  
Essam G. Soliman ◽  
Ahmed F. Hassan

Sign in / Sign up

Export Citation Format

Share Document