The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface

1978 ◽  
Vol 92 (1) ◽  
pp. 19-30 ◽  
Author(s):  
M. Halawa ◽  
A. J. C. Lee ◽  
R. S. M. Ling ◽  
S. S. Vangala
Ultrasound ◽  
2020 ◽  
pp. 1742271X2095319
Author(s):  
Stephanie F Smith ◽  
Piero Miloro ◽  
Richard Axell ◽  
Gail ter Haar ◽  
Christoph Lees

Introduction The quantification of heating effects during exposure to ultrasound is usually based on laboratory experiments in water and is assessed using extrapolated parameters such as the thermal index. In our study, we have measured the temperature increase directly in a simulator of the maternal–fetal environment, the ‘ISUOG Phantom’, using clinically relevant ultrasound scanners, transducers and exposure conditions. Methods The study was carried out using an instrumented phantom designed to represent the pregnant maternal abdomen and which enabled temperature recordings at positions in tissue mimics which represented the skin surface, sub-surface, amniotic fluid and fetal bone interface. We tested four different transducers on a commercial diagnostic scanner. The effects of scan duration, presence of a circulating fluid, pre-set and power were recorded. Results The highest temperature increase was always at the transducer–skin interface, where temperature increases between 1.4°C and 9.5°C were observed; lower temperature rises, between 0.1°C and 1.0°C, were observed deeper in tissue and at the bone interface. Doppler modes generated the highest temperature increases. Most of the heating occurred in the first 3 minutes of exposure, with the presence of a circulating fluid having a limited effect. The power setting affected the maximum temperature increase proportionally, with peak temperature increasing from 4.3°C to 6.7°C when power was increased from 63% to 100%. Conclusions Although this phantom provides a crude mimic of the in vivo conditions, the overall results showed good repeatability and agreement with previously published experiments. All studies showed that the temperature rises observed fell within the recommendations of international regulatory bodies. However, it is important that the operator should be aware of factors affecting the temperature increase.


1975 ◽  
Vol 108 ◽  
pp. 145-148 ◽  
Author(s):  
William J. Astleford ◽  
Marc A. Asher ◽  
Ulric S. Lindholm ◽  
Charles A. Rockwood

1995 ◽  
Vol 32 (5) ◽  
pp. 899-904 ◽  
Author(s):  
Jaroslav Feda

A series of 18 triaxial CIUP (undrained isotropically consolidated with pore pressure measurement) tests of fissured cemented Neogene lacustrine clay from northern Bohemia is analyzed, with special reference to the shear strength. The effects of sample disturbance, swelling, and cementation are shown to be the principal factors affecting the shear envelope. During the prepeak stage of testing, destruction of the cementation of some specimens occurs, which is reflected in the wavy form of the stress–strain diagrams. The linear strength envelopes were found to be arranged according to the amount of disturbance (as expressed in the magnitude of swelling). Cemented and uncemented specimens differ when pore-water pressure and stress–strain diagrams are compared. Key words : Miocene clay, undisturbed samples, triaxial test, structural bonds, cementation, sample disturbance.


2020 ◽  
Vol 15 ◽  
pp. 155892502094645
Author(s):  
Yao Chu ◽  
Haitao Lin ◽  
Hafsa Jamshaid ◽  
Qi Zhang ◽  
Pibo Ma

Warp-knitted brush fabrics are composed of an outer surface formed by weaving the front and rear needle beds with spacer yarns interposed between them. Warp-knitted brush fabrics can be used as a non-slip cover for car seat cushions; the adhesion between non-slip fabric and car seat is related to the shear strength of warp-knitted brush fabrics. In this article, to study the factors affecting the shear force of warp-knitted brush fabrics, three different processing methods and four different stretching speed intervals were used to find the effects of stiffeners and action of different speed intervals on shear properties of fabrics. The experimental results show that the stiffener treatment can improve the shear resistance of the warp-knitted brush fabrics, and the effect of different speed intervals can affect the shear resistance of fabrics. These findings will have a guiding significance in the design and production of warp-knitted brush fabrics applied to fabrics such as car seat cushions, and the results can also help to study the shear properties of warp-knitted brush fabrics for wider applications.


Author(s):  
Kenneth A. Mann ◽  
Mark A. Miler ◽  
Nico Verdonschot ◽  
Alan W. Eberhardt

PMMA bones cements are used routinely to fix implants to bone. The interface between cement and bone is relied on for fixation and it is well recognized that there is a biologic response to the presence of PMMA. Bleeding of the bone bed during the arthroplasty procedure, thermal necrosis from the polymerization process, and bone remodeling has been described as factors affecting the integrity of the cement-bone interface. While substantial efforts have been made to understand the mechanical characteristics of the cement-bone interface from lab-prepared specimens there is actually very little understanding of the mechanics of cement-bone interfaces that have been in service.


2013 ◽  
Vol 135 (12) ◽  
Author(s):  
Ana C. Vale ◽  
Jennifer Faustino ◽  
Luís Reis ◽  
Ana Lopes ◽  
Bruno Vidal ◽  
...  

As one of the major functions of bone is to provide structural support for the musculoskeletal system, it is important to evaluate its mechanical strength. Bones may be subjected to multiaxial stresses due to bone pathologies, accidental loads which may lead to hip, wrist fracture, or to a prosthetic joint replacement. Twist loading may lead to fractures, especially involving long bones from lower limbs. The aim of this work was to study the effect of the strain rate on the shear properties of trabecular bone samples from women with hip fracture (from 65 to 100 years). Cylindrical samples were core drilled from human femoral heads along the primary trabecular direction. The cylinder's ends were polished and embedded in blocks of polymeric material which fit the grips of the testing device. Deformation rates of 0.005, 0.01, 0.015, and 0.05 s−1 were applied. Twisting tests were conducted with or without an applied axial load of 500 N. From the torque-angular displacement curves, the shear stress–strain curves were obtained. The maximum shear strength and the shear modulus (i.e. the slope of the linear region) were determined. A large scatter of the results of the shear strength and the shear modulus was found, which is probably related to the heterogeneity of nonhealthy human bone samples. There is no significant effect of the strain rate on the maximum shear stress and the shear modulus, either in tests undertaken with or without the application of an axial load. The effect of strain rate on nonhealthy bone trabecular twisting properties did not follow the trend observed on the effect of strain rate in healthy bone, where an increase is detected.


Sign in / Sign up

Export Citation Format

Share Document