scholarly journals A stacked dense denoising–segmentation network for undersampled tomograms and knowledge transfer using synthetic tomograms

2021 ◽  
Vol 32 (3) ◽  
Author(s):  
Dimitrios Bellos ◽  
Mark Basham ◽  
Tony Pridmore ◽  
Andrew P. French

AbstractOver recent years, many approaches have been proposed for the denoising or semantic segmentation of X-ray computed tomography (CT) scans. In most cases, high-quality CT reconstructions are used; however, such reconstructions are not always available. When the X-ray exposure time has to be limited, undersampled tomograms (in terms of their component projections) are attained. This low number of projections offers low-quality reconstructions that are difficult to segment. Here, we consider CT time-series (i.e. 4D data), where the limited time for capturing fast-occurring temporal events results in the time-series tomograms being necessarily undersampled. Fortunately, in these collections, it is common practice to obtain representative highly sampled tomograms before or after the time-critical portion of the experiment. In this paper, we propose an end-to-end network that can learn to denoise and segment the time-series’ undersampled CTs, by training with the earlier highly sampled representative CTs. Our single network can offer two desired outputs while only training once, with the denoised output improving the accuracy of the final segmentation. Our method is able to outperform state-of-the-art methods in the task of semantic segmentation and offer comparable results in regard to denoising. Additionally, we propose a knowledge transfer scheme using synthetic tomograms. This not only allows accurate segmentation and denoising using less real-world data, but also increases segmentation accuracy. Finally, we make our datasets, as well as the code, publicly available.

Holzforschung ◽  
2013 ◽  
Vol 67 (2) ◽  
pp. 201-205 ◽  
Author(s):  
Adam Taylor ◽  
Bernhard Plank ◽  
Gernot Standfest ◽  
Alexander Petutschnigg

Abstract The shrinkage behavior of European beech wood was successfully observed on a time series of images obtained by high resolution X-ray computed tomography (μXCT). The calculated measures for shrinkage and shrinkage anisotropy are consistent with published data. Evidence was provided for the ‘ray restraint’ theory of shrinkage anisotropy. This technique has a high potential for the study of dynamic processes in wood at the micro-scale, though the resolution of the images is lower and the measurement times are longer in comparison to synchroton radiation μXCT.


1999 ◽  
Vol 11 (1) ◽  
pp. 199-211
Author(s):  
J. M. Winter ◽  
R. E. Green ◽  
A. M. Waters ◽  
W. H. Green

Author(s):  
I.V. Yazynina ◽  
◽  
E.V. Shelyago ◽  
A.A. Abrosimov ◽  
N.E. Grachev ◽  
...  

2019 ◽  
Vol 155 ◽  
pp. 109748
Author(s):  
Yudong Xue ◽  
Qinglei Wang ◽  
Jianbao Hu ◽  
Haijun Zhou ◽  
Qingliang Shan ◽  
...  

2019 ◽  
Vol 92 ◽  
pp. 01004
Author(s):  
Christopher Ibeh ◽  
Matteo Pedrotti ◽  
Alessandro Tarantino ◽  
Rebecca Lunn

The quality and reliability of cohesive soil laboratory test data can be significantlyaffected by sample disturbance during sampling or sample preparation. Sample disturbance may affect key design and modelling parameters such as stiffness, preconsolidation stress, compressibility and undrained shear strength, and ultimately determine particle mobilization and shear plane development. The use of X-ray computed tomography (X-CT) in the study of soil is restricted by the inverse relationship of specimen size and obtainable image resolution. This has led to the testing of miniature specimen sizes which are far less than conventional laboratory sample size in a bid to obtain high resolution images and detailed particle-scale soil properties; however, these miniature soil specimens are more prone to sample disturbance. In this work 2% muscovite was mixed with speswhite kaolin clay as a strain marker for use in X-CT. The clay soil sample was prepared from slurry and either consolidated using an oedometer or a gypsum mould. Specimens obtained from a 7 mm tube sampler were compared to lathe trimmed specimens with a diameter (Ø) of 7 mm. Results from X-CT imaging were used to study the influence of sampler type on specimen disturbance, by analysing the muscovite particle orientation of the obtained 3D images. The results show that; for samples subjected to large consolidation stress (>200kpa) lathe trimmed specimens may be subject to lesser disturbance compared to tube sampled specimens.


2013 ◽  
Vol 38 (3) ◽  
pp. 36-41
Author(s):  
Karen Di Franco

Since 2010, Book Works has been digitising material from its archive – whether finished works, ephemera, correspondence, photographs, or manuscripts – to give access to the working processes of the organisation (at www.bookworks.org.uk). The archive database is constructed around a chronological timeline and includes a search facility that allows visitors to filter and select material using a bespoke classification system. It currently comprises detailed content relating to two case studies from Book Works back catalogue: After the Freud Museum by Susan Hiller and Erasmus is late by Liam Gillick, as well as ephemera and material from other works. The project has been developed in collaboration with Ligatus Research Centre, University of the Arts London, with support from the AHRC Knowledge Transfer scheme.


Sign in / Sign up

Export Citation Format

Share Document