Minimally invasive thoracoscopic partial corpectomy of T12, followed by anterior stabilization and fusion through cage implantation with an anterior plate fixation

2016 ◽  
Vol 25 (S2) ◽  
pp. 267-269 ◽  
Author(s):  
Daniel Sauer ◽  
Franziska Heider
2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Fu Wang ◽  
Yan Wang ◽  
Jinye Dong ◽  
Yu He ◽  
Lianxin Li ◽  
...  

Abstract Background and hypothesis The typical anterolateral approach is widely used to treat proximal humerus fractures with lateral locking fixation. However, lateral fixation cannot completely avoid medial reduction loss and varus deformity especially in the cases of an unstable medial column. We present a novel medial surgical approach and technique together with a minimally invasive lateral locking plate to fix proximal humerus fractures with an unstable medial column. Materials and methods We performed an anatomical study and reported 8 cases of proximal humerus fractures with unstable medial columns treated with plate fixation through a minimally invasive anterolateral approach and medial approach. All surgeries were performed by the same single surgeon. Patients were followed clinically and radiographically at 1, 3, 6, and 12 months postoperatively. Results There was a safe region located at the medial part of the proximal humerus just beneath the articular surface. An anatomical medial locking proximal humerus plate could be placed in the medial column and did not affect the axillary nerve, blood supply of the humeral head, or stability of the shoulder joint. Successful fracture healing was achieved in all 8 cases. The function and range of motion of the shoulder joint were satisfactory 24 months postoperatively, with an average Constant score (CS) of 82.8. No reduction loss (≥ 10° in any direction), screw cutout, nonunion, or deep infection occurred. Conclusions The combined application of medial anatomical locking plate fixation and minimally invasive lateral locking plate fixation is effective in maintaining operative reduction and preventing varus collapse and implant failure in proximal humerus fractures with an unstable medial column.


2020 ◽  
Vol 32 (4) ◽  
pp. 562-569
Author(s):  
Minghao Wang ◽  
Dean Chou ◽  
Chih-Chang Chang ◽  
Ankit Hirpara ◽  
Yilin Liu ◽  
...  

OBJECTIVEBoth structural allograft and PEEK have been used for anterior cervical discectomy and fusion (ACDF). There are reports that PEEK has a higher pseudarthrosis rate than structural allograft. The authors compared pseudarthrosis, revision, subsidence, and loss of lordosis rates in patients with PEEK and structural allograft.METHODSThe authors performed a retrospective review of patients who were treated with ACDF at their hospital between 2005 and 2017. Inclusion criteria were adult patients with either PEEK or structural allograft, anterior plate fixation, and a minimum 2-year follow-up. Exclusion criteria were hybrid PEEK and allograft cases, additional posterior surgery, adjacent corpectomies, infection, tumor, stand-alone or integrated screw and cage devices, bone morphogenetic protein use, or lack of a minimum 2-year follow-up. Demographic variables, number of treated levels, interbody type (PEEK cage vs structural allograft), graft packing material, pseudarthrosis rates, revision surgery rates, subsidence, and cervical lordosis changes were collected. These data were analyzed by Pearson’s chi-square test (or Fisher’s exact test, according to the sample size and expected value) and Student t-test.RESULTSA total of 168 patients (264 levels total, mean follow-up time 39.5 ± 24.0 months) were analyzed. Sixty-one patients had PEEK, and 107 patients had structural allograft. Pseudarthrosis rates for 1-level fusions were 5.4% (PEEK) and 3.4% (allograft) (p > 0.05); 2-level fusions were 7.1% (PEEK) and 8.1% (allograft) (p > 0.05); and ≥ 3-level fusions were 10% (PEEK) and 11.1% (allograft) (p > 0.05). There was no statistical difference in the subsidence magnitude between PEEK and allograft in 1-, 2-, and ≥ 3-level ACDF (p > 0.05). Postoperative lordosis loss was not different between cohorts for 1- and 2-level surgeries.CONCLUSIONSIn 1- and 2-level ACDF with plating involving the same number of fusion levels, there was no statistically significant difference in the pseudarthrosis rate, revision surgery rate, subsidence, and lordosis loss between PEEK cages and structural allograft.


2019 ◽  
Vol 44 (5) ◽  
pp. 462-467 ◽  
Author(s):  
Teun Teunis ◽  
Sjoerd Meijer ◽  
Jesse Jupiter ◽  
Daniel Rikli ◽  

This study aimed to determine the association of teardrop angle and anteroposterior distance with anterior lunate facet displacement and articular congruity before and after anterior plating of distal radial fractures. We included 36 patients with complete intra-articular distal radial fractures with separate anterior lunate facet fragments. On radiographs we determined the teardrop angle and anteroposterior distance. On digital three-dimensional models we measured proximal-distal, anteroposterior and ulnoradial anterior lunate facet displacement, and we outlined the gap surface area. Preoperatively, teardrop angle was highly associated with the extent of anterior lunate facet displacement. Increased anteroposterior distance was mainly associated with articular incongruity after anterior plate fixation. This information may reduce the need of preoperative computed tomography scans in fractures with a normal tear drop angle. This is particularly useful in low-resource settings.


2017 ◽  
Vol 20 (1) ◽  
pp. 6-14 ◽  
Author(s):  
Andrew Craig ◽  
Philip G Witte ◽  
Tristram Moody ◽  
Karen Harris ◽  
Harry W Scott

Objectives The objective was to assess the medium- and long-term outcomes (radiographic and owner questionnaire) of feline tibial diaphyseal fractures with orthogonal plate fixation via a minimally invasive plate osteosynthesis (MIPO) approach. Methods Medical records and radiographs of cats that had tibial diaphyseal fractures stabilised with orthogonal plates were obtained (2012–2016). Immediate postoperative radiographs were reviewed to assess the construct configuration and follow-up radiographs (where available) were used to assess bone healing and implant-related complications. An owner-completed questionnaire (feline musculoskeletal pain index [FMPI]) was used at a minimum of 6 months following surgery to assess the cats’ ability to perform normal activities. Results Eight feline tibial diaphyseal fractures met the inclusion criteria. One major complication was observed, most likely due to an operative technical error. There were no further complications following revision surgery. Six of the eight cases that had radiographic follow-up either had clinical bone union or showed evidence of bone healing. All cases were classified as successful according to FMPI. Conclusions and relevance Orthogonal plating of feline tibial diaphyseal fractures via an MIPO approach resulted in successful outcomes and a lower complication rate compared with previously reported techniques.


2016 ◽  
Vol 41 (videosuppl1) ◽  
pp. 1
Author(s):  
Martin H. Pham ◽  
Andre M. Jakoi ◽  
Patrick C. Hsieh

Lumbar interbody fusion is an important technique for the treatment of degenerative disc disease and degenerative scoliosis. The oblique lumbar interbody fusion (OLIF) establishes a minimally invasive retroperitoneal exposure anterior to the psoas and lumbar plexus. In this video case presentation, the authors demonstrate the techniques of the OLIF at L5–S1 performed on a 69-year-old female with degenerative scoliosis as one component of an overall strategy for her deformity correction.The video can be found here: https://youtu.be/VMUYWKLAl0g.


2010 ◽  
Vol 12 (4) ◽  
pp. 372-380 ◽  
Author(s):  
Dean G. Karahalios ◽  
Taro Kaibara ◽  
Randall W. Porter ◽  
Udaya K. Kakarla ◽  
Phillip M. Reyes ◽  
...  

Object An interspinous anchor (ISA) provides fixation to the lumbar spine to facilitate fusion. The biomechanical stability provided by the Aspen ISA was studied in applications utilizing an anterior lumbar interbody fusion (ALIF) construct. Methods Seven human cadaveric L3–S1 specimens were tested in the following states: 1) intact; 2) after placing an ISA at L4–5; 3) after ALIF with an ISA; 4) after ALIF with an ISA and anterior screw/plate fixation system; 5) after removing the ISA (ALIF with plate only); 6) after removing the plate (ALIF only); and 7) after applying bilateral pedicle screws and rods. Pure moments (7.5 Nm maximum) were applied in flexion and extension, lateral bending, and axial rotation while recording angular motion optoelectronically. Changes in angulation as well as foraminal height were also measured. Results All instrumentation variances except ALIF alone reduced angular range of motion (ROM) significantly from normal in all directions of loading. The ISA was most effective in limiting flexion and extension (25% of normal) and less effective in reducing lateral bending (71% of normal) and axial rotation (71% of normal). Overall, ALIF with an ISA provided stability that was statistically equivalent to ALIF with bilateral pedicle screws and rods. An ISA-augmented ALIF allowed less ROM than plate-augmented ALIF during flexion, extension, and lateral bending. Use of the ISA resulted in flexion at the index level, with a resultant increase in foraminal height. Compensatory extension at the adjacent levels prevented any significant change in overall sagittal balance. Conclusions When used with ALIF at L4–5, the ISA provides immediate rigid immobilization of the lumbar spine, allowing equivalent ROM to that of a pedicle screw/rod system, and smaller ROM than an anterior plate. When used with ALIF, the ISA may offer an alternative to anterior plate fixation or bilateral pedicle screw/rod constructs.


2014 ◽  
Vol 2014 ◽  
pp. 1-3 ◽  
Author(s):  
Mark J. Russo ◽  
John Gnezda ◽  
Aurelie Merlo ◽  
Elizabeth M. Johnson ◽  
Mohammad Hashmi ◽  
...  

Background. Ministernotomy incisions have been increasingly used in a variety of settings. We describe a novel approach to ministernotomy using arrowhead incision and rigid sternal fixation with a standard sternal plating system.Methods. A small, midline, vertical incision is made from the midportion of the manubrium to a point just above the 4th intercostal mark. The sternum is opened in the shape of an inverted T using two oblique horizontal incisions from the midline to the sternal edges. At the time of chest closure, the three bony segments are aligned and approximated, and titanium plates (Sternalock, Jacksonville, Florida) are used to fix the body of the sternum back together.Results. This case series includes 11 patients who underwent arrowhead ministernotomy with rigid sternal plate fixation for aortic surgery. The procedures performed were axillary cannulation (n=2), aortic root replacement (n=3), valve sparing root replacement (n=3), and replacement of the ascending aorta (n=11) and/or hemiarch (n=2). Thirty-day mortality was 0%; there were no conversions, strokes, or sternal wound infections.Conclusions. Arrowhead ministernotomy with rigid sternal plate fixation is an adequate minimally invasive approach for surgery of the ascending aorta and aortic root.


Sign in / Sign up

Export Citation Format

Share Document