Imaging for approach selection of TAVI: assessment of the aorto-iliac tract diameter by computed tomography-angiography versus projection angiography

2013 ◽  
Vol 30 (2) ◽  
pp. 399-405 ◽  
Author(s):  
E. M. A. Wiegerinck ◽  
H. A. Marquering ◽  
N. Y. Oldenburger ◽  
M. A. Elattar ◽  
R. N. Planken ◽  
...  
Author(s):  
Christopher M. Schneider ◽  
Patrick A. Palines ◽  
Daniel J. Womac ◽  
Charles T. Tuggle ◽  
Hugo St Hilaire ◽  
...  

Abstract Background Computed tomography angiography (CTA) has been widely used for perforator mapping in abdominal-based reconstruction, but it is less widespread in the anterolateral thigh (ALT) flap. However, CTA may be quite useful for ALT planning, as this flap has demonstrated substantial variability in intrapatient bilateral vascular anatomy. This study investigated whether standard use of preoperative CTA resulted in selection of the donor extremity with preferential perforator anatomy, and whether this affected operative time and postoperative outcomes. Methods A retrospective review of 105 patients who underwent proposed ALT flap reconstruction was performed. Seventy-nine patients received bilateral lower extremity CTAs, which were evaluated for dominant perforator anatomy (septocutaneous, musculoseptocutaneous, or musculocutaneous). Donor extremity selection was noted, and predicted perforator anatomy was compared with that encountered intraoperatively. Results Among the 73 patients who received bilateral imaging and ultimately received an ALT, congruent findings between imaging and surgical exploration were observed in 51 (69.8%) patients. Thirty (37.9%) patients had asymmetric perforator anatomy between their bilateral extremities on imaging. Among these, the leg with optimal perforator anatomy was selected in 70% of cases. There were no significant reductions among postoperative complication rates, but selection of the donor site with preferential anatomy was associated with a decrease in operative time (p = 0.049) among patients undergoing extremity reconstruction. Conclusion CTA is a useful tool for optimizing donor site selection for ALT flaps and reducing operative time. We believe that standard use of preoperative CTA in ALTs warrants further consideration.


VASA ◽  
2012 ◽  
Vol 41 (2) ◽  
pp. 132-135 ◽  
Author(s):  
Krohn ◽  
Gebauer ◽  
Hübler ◽  
Beck

The mid-aortic syndrome is an uncommon clinical condition characterized by severe narrowing of the descending aorta, usually with involvement of its renal and visceral branches, presenting with uncontrollably elevated blood pressures of the upper body, renal and cardiac failure, intestinal ischemia, encephalopathy symptoms and claudication of the lower limbs, although clinical presentation is variable. In this article we report the case of an eleven-year-old patient with the initial diagnosis of a mid-aortic syndrome and present the computed tomography angiography pictures and reconstructions before and after surgical therapy.


2020 ◽  
Vol 6 (2) ◽  
pp. 78-81
Author(s):  
Md Tauhidul Islam Chowdhury ◽  
Mohammad Shah Jahirul Hoque Chowdhury ◽  
Mohammad Sadekur Rahman Sarkar ◽  
KM Ahasan Ahmed ◽  
Md Nazmul Kabir ◽  
...  

Background: In evaluation of non-traumatic subarachnoid hemorrhage CT angiography (CTA) has 97-98% sensitivity and near 100% specificity. Objective: This study was conducted to evaluate the CTA findings of CT positive non traumatic subarachnoid hemorrhage. Methodology: This is an observational cross sectional study performed in Neurology department of National Institute of Neurosciences and Hospital, Dhaka over one year period (January 2019 to December 2019). Total 87 CT positive subarachnoid hemorrhage cases were purposively included in this study. All CT positive patients underwent CTA of Cerebral vessels for further evaluation. The angiography were evaluated by competent neuro-radiologists blinded about the study. Result: Among 87 patients, 40.2% were male and 59.8% were female. The average age was 53.33±11.1 years. Among the studied patient the source of bleeding was found 78.16% aneurysmal and 21.84% non-aneurysmal. 85.30% patients had single aneurysm and 14.70% had multiple aneurysm. The highest number of patient had Acom aneurysm (41.17%) followed by MCA (22.05%), ICA (13.23%), ACA (7.35%) and vertebral artery (1.14%) in order of frequency. Among the multiple aneurysm group most of the patients had combination of Acom, MCA and ICA aneurysm. Conclusion: From this study, we can conclude that CTA can be used as the primary diagnostic tool in evaluation of spontaneous SAH. Journal of National Institute of Neurosciences Bangladesh, 2020;6(2): 78-81


2011 ◽  
Vol 12 (1) ◽  
pp. 62-63 ◽  
Author(s):  
Thomas Henzler ◽  
Steffen Diehl ◽  
Susanne Jochum ◽  
Tim Sueselbeck ◽  
Stefan O Schoenberg ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document