scholarly journals Cell-based non-invasive prenatal testing for monogenic disorders: confirmation of unaffected fetuses following preimplantation genetic testing

Author(s):  
Christian Liebst Frisk Toft ◽  
Hans Jakob Ingerslev ◽  
Ulrik Schiøler Kesmodel ◽  
Lotte Hatt ◽  
Ripudaman Singh ◽  
...  

Abstract Purpose Proof of concept of the use of cell-based non-invasive prenatal testing (cbNIPT) as an alternative to chorionic villus sampling (CVS) following preimplantation genetic testing for monogenic disorders (PGT-M). Method PGT-M was performed by combined testing of short tandem repeat (STR) markers and direct mutation detection, followed by transfer of an unaffected embryo. Patients who opted for follow-up of PGT-M by CVS had blood sampled, from which potential fetal extravillous throphoblast cells were isolated. The cell origin and mutational status were determined by combined testing of STR markers and direct mutation detection using the same setup as during PGT. The cbNIPT results with respect to the mutational status were compared to those of genetic testing of the CVS. Results Eight patients had blood collected between gestational weeks 10 and 13, from which 33 potential fetal cell samples were isolated. Twenty-seven out of 33 isolated cell samples were successfully tested (82%), of which 24 were of fetal origin (89%). This corresponds to a median of 2.5 successfully tested fetal cell samples per case (range 1–6). All fetal cell samples had a genetic profile identical to that of the transferred embryo confirming a pregnancy with an unaffected fetus, in accordance with the CVS results. Conclusion These findings show that although measures are needed to enhance the test success rate and the number of cells identified, cbNIPT is a promising alternative to CVS. Trial registration number N-20180001

Genes ◽  
2020 ◽  
Vol 11 (8) ◽  
pp. 871 ◽  
Author(s):  
Martine De Rycke ◽  
Veerle Berckmoes

Preimplantation genetic testing (PGT) has evolved into a well-established alternative to invasive prenatal diagnosis, even though genetic testing of single or few cells is quite challenging. PGT-M is in theory available for any monogenic disorder for which the disease-causing locus has been unequivocally identified. In practice, the list of indications for which PGT is allowed may vary substantially from country to country, depending on PGT regulation. Technically, the switch from multiplex PCR to robust generic workflows with whole genome amplification followed by SNP array or NGS represents a major improvement of the last decade: the waiting time for the couples has been substantially reduced since the customized preclinical workup can be omitted and the workload for the laboratories has decreased. Another evolution is that the generic methods now allow for concurrent analysis of PGT-M and PGT-A. As innovative algorithms are being developed and the cost of sequencing continues to decline, the field of PGT moves forward to a sequencing-based, all-in-one solution for PGT-M, PGT-SR, and PGT-A. This will generate a vast amount of complex genetic data entailing new challenges for genetic counseling. In this review, we summarize the state-of-the-art for PGT-M and reflect on its future.


2019 ◽  
Vol 38 ◽  
pp. e41-e42
Author(s):  
Kuznyetsov Valeriy ◽  
Madjunkova Svetlana ◽  
Antes Ran ◽  
Abramov Rina ◽  
Motamedi Gelareh ◽  
...  

2020 ◽  
Vol 114 (3) ◽  
pp. e425
Author(s):  
Meir Olcha ◽  
Manar Elzaky ◽  
Malgorzata Jaremko ◽  
Zaher Merhi ◽  
John J. Zhang

2021 ◽  
Vol 36 (Supplement_1) ◽  
Author(s):  
F Spinella ◽  
A Victor ◽  
F Barnes ◽  
C Zouves ◽  
A Besser ◽  
...  

Abstract Study question To explore the effect of chromosomal mosaicism detected in preimplantation genetic testing (PGT-A) on prenatal and postnatal outcome of mosaic embryo pregnancies Summary answer No significant difference between euploid and mosaic embryos was observed in terms of weeks of gestation, average weight, and developmental defect of the babies born What is known already Mosaic embryos have the potential to implant and develop into healthy babies. Transfer of these embryos is now offered as an option for women who undergo IVF resulting in no euploid embryos. While, prenatal diagnosis has shown the depletion of chromosomal mosaicism in mosaic embryos, several concerns remain. For instance, the direct effects of different kind of mosaicism on prenatal/postnatal outcome and the possibility that intra-biopsy mosaicism in the TE is a poor predictor of the ploidy status of the ICM. Thus, there is certainly a need for comprehensive analyses of obstetrical and neonatal outcome data of transferred mosaic embryos. Study design, size, duration Compiled analysis from multicenter data on transfers of mosaic embryos (n = 1,000) and their outcome, with comparison to a euploid control group (n = 5,561). To explore the effect of embryonic mosaicism on newborns, we matched mosaic embryos resulting in a birth with a euploid embryo by a series of parameters (maternal age, embryo morphology, and indication for PGT-A). Prenatal tests and birth characteristics of > 200 neonates from mosaic embryo transfers were compared to > 200 euploid embryos. Participants/materials, setting, methods PGT-A was performed on blastocyst-stage embryos with 24-Chromosome whole genome amplification (WGA)-based Next Generation Sequencing (NGS). In accordance with established guidelines, embryos were categorized as mosaic when PGT-A results indicated 20-80% aneuploid content. Prenatal testing where performed in 30% of pregnancies with amniocentesis, 4% did an extra analysis for potential UPD for the suspected mosaic chromosome, and an additional 16% performed chorionic villus sampling (CVS) and 9.5% performed noninvasive prenatal testing (NIPT). Main results and the role of chance Of the 465 mosaic embryos that implanted, about 20% miscarried, and out of those, 75% were early spontaneous abortions. Of the pregnancies, 3 out of 368 were stillborn (2 out of them were twins that were extremely premature at 23 weeks, and the other died during pregnancy from a heart defect). The remaining 99% of those have been born or are late ongoing pregnancies at the time of analysis. Prenatal tests were performed in > 200 pregnancies and the vast majority tested normal. All 5 abnormal cases were amniocentesis tests showing microdeletions or insertions of sizes smaller than the resolution used during PGT-A, so they were unrelated to the mosaicism detected with PGT-A. In fact, in none of the cases did the prenatal test reflect the mosaicism detected at the embryonic stage. Matching each of the 162 mosaic embryos resulting in a birth with a euploid embryo, we found that the length of gestation was similar on average, and so was the average weight of the babies at birth. We also gathered information on the routine physical examination performed on babies at birth, and of those 162 babies from mosaic embryo transfers, none had obvious developmental defects or gross abnormalities. Limitations, reasons for caution Even though newborns resulting from mosaic embryo transfers in this study invariably appeared healthy by routine examination, concerns for long-term health cannot yet be entirely dispelled. The question must therefore be carefully considered by each clinic and patient situation. Wider implications of the findings Prenatal testing of > 200 pregnancies from mosaic embryo transfers showed no incidence of mosaicism that matched the PGT-A findings, indicating the involvement of self-corrective mechanisms. Pregnancy and obstetric data indicates that mosaic embryos prevailing through gestation and birth have similar chromosomal and physiological health compared to euploid embryos. Trial registration number none


Sign in / Sign up

Export Citation Format

Share Document