scholarly journals In vivo derivative NMR spectroscopy for simultaneous improvements of resolution and signal-to-noise-ratio: Case study, Glioma

2021 ◽  
Vol 59 (9) ◽  
pp. 2133-2178 ◽  
Author(s):  
Dževad Belkić ◽  
Karen Belkić

AbstractThe theme of this study is derivative nuclear magnetic resonance (dNMR) spectroscopy. This versatile methodology of peering into the molecular structure of general matter is common to e.g. analytical chemistry and medical diagnostics. Theoretically, the potential of dNMR is huge and the art is putting it into practice. The implementation of dNMR (be it in vitro or in vivo) is wholly dependent on the manner in which the encoded time signals are analyzed. These acquired data contain the entire information which is, however, opaque in the original time domain. Their frequency-dependent dual representation, a spectrum, can be transparent, provided that the appropriate signal processors are used. In signal processing, there are shape and parameter estimators. The former processors are qualitative as they predict only the forms of the lineshape profiles of spectra. The latter processors are quantitative because they can give the peak parameters (positions, widths, heights, phases). Both estimators can produce total shape spectra or envelopes. Additionally, parameter estimators can yield the component spectra, based on the reconstructed peak quantifiers. In principle, only parameter estimators can solve the quantification problem (harmonic inversion) to determine the structure of the time signal and, hence, the quantitative content of the investigated matter. The derivative fast Fourier transform (dFFT) and the derivative fast Padé transform (dFPT) are the two obvious candidates to employ for dNMR spectroscopy. To make fair comparisons between the dFFT and dFPT, the latter should also be applied as a shape estimator. This is what is done in the present study, using the time signals encoded from a patient with brain tumor (glioma) using a 1.5T clinical scanner. Moreover, within the dFPT itself, the shape estimations are compared to the parameter estimations. The goal of these testings is to see whether, for in vivo dNMR spectroscopy, shape estimations by the dFPT could quantify (without fitting), similarly to parameter estimations. We check this key point in two successive steps. First, we compare the envelopes from the shape and parameter estimations in the dFPT. The second comparison is between the envelopes and components from the shape and parameter estimations, respectively, in the dFPT. This plan for benchmarking shape estimations by the dFPT is challenging both on the level of data acquisition and data analysis. The data acquisition reported here provides encoded time signals of short length, only 512 as compared to 2048, which is customarily employed. Moreover, the encoding echo time was long (272 ms) at which most of resonances assigned to metabolites with shorter spin-spin relaxations are likely to be obliterated from the frequency spectra. Yet, in face of such seemingly insurmountable obstacles, we are looking into the possibility to extract diagnostically relevant information, having particularly in focus the resonances for recognized cancer biomarkers, notably lactate, choline and phosphocholine. Further, we want to see how many of the remaining resonances in the spectra could accurately be identified with clinical reliability as some of them could also be diagnostically relevant. From the mathematical stance, we are here shaking the sharp border between shape and parameter estimators. That border stood around for a long time within nonderivative estimations. However, derivative shape estimations have a chance to tear the border down. Recently, shape estimations by the dFPT have been shown to lead such a trend as this processor could quantify using the time signals encoded from a phantom (a test sample of known content). Further, the present task encounters a number of additional challenges, including a low signal-to-noise ratio (SNR) and, of course, the unknown content of the scanned tissue. Nevertheless, we are determined to find out whether the nonparametric dFPT can deliver the unique quantification-equipped shape estimation and, thus, live up to the expectation of derivative processing: a long-sought simultaneous improvement of resolution and SNR. In every facet of in vivo dNMR, we found that shape estimations by the dFPT has successfully passed the outlined most stringent tests. It begins with transforming itself to a parameter estimator (already with the 3rd and 4th derivatives). It ends with reconstructing some 54 well-isolated resonances. These include the peaks assigned to recognized cancer biomarkers. In particular, a clear separation of choline from phosphocholine is evidenced for the first time by reliance upon the dFPT with its shape estimations alone.

2012 ◽  
Vol 108 (10) ◽  
pp. 2837-2845 ◽  
Author(s):  
Go Ashida ◽  
Kazuo Funabiki ◽  
Paula T. Kuokkanen ◽  
Richard Kempter ◽  
Catherine E. Carr

Owls use interaural time differences (ITDs) to locate a sound source. They compute ITD in a specialized neural circuit that consists of axonal delay lines from the cochlear nucleus magnocellularis (NM) and coincidence detectors in the nucleus laminaris (NL). Recent physiological recordings have shown that tonal stimuli induce oscillatory membrane potentials in NL neurons (Funabiki K, Ashida G, Konishi M. J Neurosci 31: 15245–15256, 2011). The amplitude of these oscillations varies with ITD and is strongly correlated to the firing rate. The oscillation, termed the sound analog potential, has the same frequency as the stimulus tone and is presumed to originate from phase-locked synaptic inputs from NM fibers. To investigate how these oscillatory membrane potentials are generated, we applied recently developed signal-to-noise ratio (SNR) analysis techniques (Kuokkanen PT, Wagner H, Ashida G, Carr CE, Kempter R. J Neurophysiol 104: 2274–2290, 2010) to the intracellular waveforms obtained in vivo. Our theoretical prediction of the band-limited SNRs agreed with experimental data for mid- to high-frequency (>2 kHz) NL neurons. For low-frequency (≤2 kHz) NL neurons, however, measured SNRs were lower than theoretical predictions. These results suggest that the number of independent NM fibers converging onto each NL neuron and/or the population-averaged degree of phase-locking of the NM fibers could be significantly smaller in the low-frequency NL region than estimated for higher best-frequency NL.


2013 ◽  
Vol 4 (10) ◽  
pp. 2095 ◽  
Author(s):  
Claudio Vinegoni ◽  
Sungon Lee ◽  
Paolo Fumene Feruglio ◽  
Pasquina Marzola ◽  
Matthias Nahrendorf ◽  
...  

2021 ◽  
Vol 15 ◽  
Author(s):  
Thanet Pakpuwadon ◽  
Kiyotaka Sasagawa ◽  
Mark Christian Guinto ◽  
Yasumi Ohta ◽  
Makito Haruta ◽  
...  

In this study, we propose a complementary-metal-oxide-semiconductor (CMOS) image sensor with a self-resetting system demonstrating a high signal-to-noise ratio (SNR) to detect small intrinsic signals such as a hemodynamic reaction or neural activity in a mouse brain. The photodiode structure was modified from N-well/P-sub to P+/N-well/P-sub to increase the photodiode capacitance to reduce the number of self-resets required to decrease the unstable stage. Moreover, our new relay board was used for the first time. As a result, an effective SNR of over 70 dB was achieved within the same pixel size and fill factor. The unstable state was drastically reduced. Thus, we will be able to detect neural activity. With its compact size, this device has significant potential to become an intrinsic signal detector in freely moving animals. We also demonstrated in vivo imaging with image processing by removing additional noise from the self-reset operation.


Author(s):  
Daniele De Marchi ◽  
Alessandra Flori ◽  
Nicola Martini ◽  
Giulio Giovannetti

Background: Cardiac magnetic resonance evaluations generally require a radiofrequency coil setup comprising a transmit whole-body coil and a receive coil. In particular, radiofrequency phased-array coils are employed to pick up the signals emitted by the nuclei with high signal-tonoise ratio and a large region of sensitivity. Methods: Literature discussed different technical issues on how to minimize interactions between array elements and how to combine data from such elements to yield optimum Signal-to-Noise Ratio images. However, image quality strongly depends upon the correct coil position over the heart and of one array coil portion with respect to the other. Results: In particular, simple errors in coil positioning could cause artifacts carrying to an inaccurate interpretation of cardiac magnetic resonance images. Conclusion: This paper describes the effect of array elements misalignment, starting from coil simulation to cardiac magnetic resonance acquisitions with a 1.5 T scanner. </P><P> Phased-array coil simulation was performed using the magnetostatic approach; moreover, phantom and in vivo experiments with a commercial 8-elements cardiac phased-array receiver coil permitted to estimate signal-to-noise ratio and B1 mapping for aligned and shifted coil.


2021 ◽  
pp. 019459982110492
Author(s):  
Allan M. Henslee ◽  
Christopher R. Kaufmann ◽  
Matt D. Andrick ◽  
Parker T. Reineke ◽  
Viral D. Tejani ◽  
...  

Objective Electrocochleography (ECochG) is increasingly being used during cochlear implant (CI) surgery to detect and mitigate insertion-related intracochlear trauma, where a drop in ECochG signal has been shown to correlate with a decline in hearing outcomes. In this study, an ECochG-guided robotics-assisted CI insertion system was developed and characterized that provides controlled and consistent electrode array insertions while monitoring and adapting to real-time ECochG signals. Study Design Experimental research. Setting A research laboratory and animal testing facility. Methods A proof-of-concept benchtop study evaluated the ability of the system to detect simulated ECochG signal changes and robotically adapt the insertion. Additionally, the ECochG-guided insertion system was evaluated in a pilot in vivo sheep study to characterize the signal-to-noise ratio and amplitude of ECochG recordings during robotics-assisted insertions. The system comprises an electrode array insertion drive unit, an extracochlear recording electrode module, and a control console that interfaces with both components and the surgeon. Results The system exhibited a microvolt signal resolution and a response time <100 milliseconds after signal change detection, indicating that the system can detect changes and respond faster than a human. Additionally, animal results demonstrated that the system was capable of recording ECochG signals with a high signal-to-noise ratio and sufficient amplitude. Conclusion An ECochG-guided robotics-assisted CI insertion system can detect real-time drops in ECochG signals during electrode array insertions and immediately alter the insertion motion. The system may provide a surgeon the means to monitor and reduce CI insertion–related trauma beyond manual insertion techniques for improved CI hearing outcomes.


1998 ◽  
Vol 52 (7) ◽  
pp. 943-951 ◽  
Author(s):  
E. V. Trujillo ◽  
D. R. Sandison ◽  
U. Utzinger ◽  
N. Ramanujam ◽  
M. Follen Mitchell ◽  
...  

Recent clinical trials have demonstrated the potential of fluorescence spectroscopy for in vivo diagnosis of pathology. There is significant potential to reduce the cost and complexity of instrumentation to measure tissue spectra; however, careful analysis is required to maximize performance and minimize cost. One measure of performance is the signal-to-noise ratio (SNR) of the resulting data. This paper describes a method to predict the SNR of a given optical design for a particular tissue application. In order to calculate the expected SNR, two pieces of information are required: (1) the throughput and inherent noise of the system and (2) a quantitative relationship between the illumination energy and the resulting tissue fluorescence available for collection, which we define as the tissue fluorescence efficiency (FE). We present a method to calculate the fluorescence efficiency of tissue from in vivo measurements of tissue fluorescence. We report FE measurements of the normal and precancerous human cervix in vivo at 337, 380, and 460 nm excitation. We also present and evaluate a method to estimate the throughput and noise of various spectrometers and predict the expected SNR for tissue spectra by using the measured tissue FE. For squamous cervical tissue, as the degree of the disease increases, FE decreases, and as the excitation wavelength increases, FE decreases. Cervical tissue FE varies more than two orders of magnitude, depending on the tissue type and on the excitation wavelength used. Our SNR calculations, based on measured values of tissue FE, demonstrate agreement within a factor of 1.3 of the measured SNR on average. This method can be used to estimate the performance of different spectrometer designs for clinical use.


2014 ◽  
Vol 513-517 ◽  
pp. 3818-3821
Author(s):  
Zhou Yang Bi ◽  
Jian Hui Chen ◽  
Wen Jie Ju ◽  
Ming Wang ◽  
Ji Chen Li

The article established the mathematical model of ultrasonic flaw echo signals. First, the basic theory of wavelet transform is introduced, the principle of the wavelet threshold de-noising method is analyzed; Then on the basis of soft and hard threshold function, the paper proposes a method based on lifting wavelet de-noising. And from two aspects of signal-to-noise ratio (SNR) and mean square error (MSE) the de-noising performance is analysed. The results show that the method improved the shortcomings of soft and hard threshold de-noising method, and got a better de-noising performance and higher signal-to-noise ratio. So in real-time signal de-noising aspect the lifting wavelet has a very good application prospect.


2018 ◽  
Vol 18 (04) ◽  
pp. 1850037 ◽  
Author(s):  
SEYED ALI ELAHI ◽  
NATHANAEL CONNESSON ◽  
YOHAN PAYAN

In-vivo characterization of soft tissues is a key step toward biomechanical simulation and planning of intra-operative assisted surgery. To achieve this, aspiration method is a standard technique: tissue is aspirated through a hole while measuring the pressure and associated apex height. An inverse problem is then solved to identify the material mechanical properties. In the literature, the apex height is usually measured using a camera, which induces design difficulties, in particular in regards on the required sterilization process for in-vivo measurements. In this paper, the idea is to replace the apex height optical measurement by the measurement of the aspirated tissue volume. The proposed method enables to reduce the system head to a simple tube: sterilizations becomes easy and the system is disposable after use. The proposed system is thus the simplest, lightest and cheapest one could achieve. It is also to the authors knowledge the first time ever in aspiration method that the aspired volume is the extracted data. As the data signal-to-noise ratio is the main factor impacting any applied inverse method when extracting the mechanical properties, the aim of this work is to assess and compare the experimental signal-to-noise ratio in the raw volume measurements obtained either optically or with the method proposed. Explicit results of inverse methods using volumes as input data are not presented in this paper for concision purpose. The effects on accuracy of various experimental parameters has been investigated and quantified: the volume measurement has proved to present a same order or even better signal-to-noise ratio compared to optical measurements.