A High-Capacity Single-Channel MDM-OFDM-IsOWC Transmission Link with Improved Detection

Author(s):  
Mehtab Singh ◽  
Jyoteesh Malhotra
2020 ◽  
Vol 238 ◽  
pp. 01003
Author(s):  
Z.G. Lu ◽  
J.R. Liu ◽  
Y.X. Mao ◽  
K. Zeb ◽  
G.C. Liu ◽  
...  

We will present the design, growth, fabrication, electronic control and packaging of the InAs/InP quantum dot (QD) multi-wavelength lasers (MWLs) developed by AEP of NRC in Canada. Their key technical specifications include L-I-V curves, optical and RF beating spectra, relative intensity noise (RIN), and optical phase noise of each individual wavelength channel, as well as timing jitter are investigated. Data bandwidth transmission capacity of 5.376 Tbit/s and 10.3 Tbit/s respectively in the PAM-4 and 16-QAM modulation formats are demonstrated by only using a single QD MWL chip. We have also developed a novel monolithic InAs/InP QD dual-wavelength (DW) DFB laser as a compact optical beat source to generate millimeter-wave (MMW) signals. Because of using a common cavity, highly coherent and correlated optical modes with optical linewidth as low as 15.83 kHz, spectrally pure MMW signals around 46.8 GHz with a linewidth down to 26.1 kHz were experimentally demonstrated. By using this QD DW-DFB laser, a 1Gbaud (2Gbps) MMW over-fiber transmission link is demonstrated with PAM-4 signals. The results show that the demonstrated device is suitable for high speed high capacity MMW fiber-wireless integrated fronthaul of 5G networks.


2016 ◽  
Vol 8 (2) ◽  
pp. 1-10 ◽  
Author(s):  
Liangshun Han ◽  
Song Liang ◽  
Junjie Xu ◽  
Lijun Qiao ◽  
Hongliang Zhu ◽  
...  

Author(s):  
P. Trebbia ◽  
P. Ballongue ◽  
C. Colliex

An effective use of electron energy loss spectroscopy for chemical characterization of selected areas in the electron microscope can only be achieved with the development of quantitative measurements capabilities.The experimental assembly, which is sketched in Fig.l, has therefore been carried out. It comprises four main elements.The analytical transmission electron microscope is a conventional microscope fitted with a Castaing and Henry dispersive unit (magnetic prism and electrostatic mirror). Recent modifications include the improvement of the vacuum in the specimen chamber (below 10-6 torr) and the adaptation of a new electrostatic mirror.The detection system, similar to the one described by Hermann et al (1), is located in a separate chamber below the fluorescent screen which visualizes the energy loss spectrum. Variable apertures select the electrons, which have lost an energy AE within an energy window smaller than 1 eV, in front of a surface barrier solid state detector RTC BPY 52 100 S.Q. The saw tooth signal delivered by a charge sensitive preamplifier (decay time of 5.10-5 S) is amplified, shaped into a gaussian profile through an active filter and counted by a single channel analyser.


Author(s):  
Shaohua Lu ◽  
Weidong Hu ◽  
Xiaojun Hu

Due to their low cost and improved safety compared to lithium-ion batteries, sodium-ion batteries have attracted worldwide attention in recent decades.


1968 ◽  
Vol 11 (1) ◽  
pp. 189-193 ◽  
Author(s):  
Lois Joan Sanders

A tongue pressure unit for measurement of lingual strength and patterns of tongue pressure is described. It consists of a force displacement transducer, a single channel, direct writing recording system, and a specially designed tongue pressure disk, head stabilizer, and pressure unit holder. Calibration with known weights indicated an essentially linear and consistent response. An evaluation of subject reliability in which 17 young adults were tested on two occasions revealed no significant difference in maximum pressure exerted during the two test trials. Suggestions for clinical and research use of the instrumentation are noted.


Sign in / Sign up

Export Citation Format

Share Document