Shaking table test study on seismic performance of inclined pile foundations in liquefiable soil

2020 ◽  
Vol 79 (17) ◽  
Author(s):  
Wenlong Chen ◽  
Jianlin Ma ◽  
Shuai Cao ◽  
Qinke Wang ◽  
Mengting Wang
2015 ◽  
Vol 104 (1) ◽  
pp. 1-8
Author(s):  
Kenichi Tahara ◽  
Yasuhito Sasaki ◽  
Yukihiro Sato ◽  
Satoshi Sasaki ◽  
Shojiro Motoyui

2012 ◽  
Vol 238 ◽  
pp. 337-340 ◽  
Author(s):  
Yu Run Li ◽  
Yan Liang ◽  
Xing Wei ◽  
Yun Long Wang ◽  
Zhen Zhong Cao

The study on lateral dynamic response of pile foundation in liquefiable soil is a significant part about seismic damage. In this paper, a new data acquisition system of FBG and calculation methods is used in the small shaking table test. The results show that FBG method used in this test is proved to be efficient and acceptable in both time characteristics and precision characteristics, it may be widely applied in the future doubtlessly. What’s more, the characteristics of p-y curves in different peak accelerations are discussed. And varying of maximum stress and displacement by corresponding acceleration is discussed. A contrast about p-y curve between dry sand and saturate sand is related, which provides a new direction in research about p-y curve.


2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Haibo Wang ◽  
Yongfeng Cheng ◽  
Zhicheng Lu ◽  
Zhubing Zhu ◽  
Shujun Zhang

Pillar electrical equipment is an important part of substations. The application of composite materials in pillar equipment can facilitate the improvement of the seismic performance of electrical equipment. In this paper, the test of elastic modulus and bending rigidity was conducted for individual composite elements in insulators and arresters, and the calculation formula for bending rigidity at the composite flange cementing connections was put forward. The numerical simulation model for the earthquake simulation shaking table test of ±1,100 kV composite pillar insulators was established, in which the bending rigidity value for the flange cementing part was obtained by the test or calculation formula. The numerical simulation results were compared with the earthquake simulation shaking table test results, the dynamic characteristics and seismic response of the model were compared, respectively, the validity of the proposed calculation formula for flange bending rigidity of composite cementing parts was verified, and a convenient and effective means was provided for calculating the seismic performance of composite electrical equipment.


2019 ◽  
Vol 2019 ◽  
pp. 1-17 ◽  
Author(s):  
Shujin Li ◽  
Cai Wu ◽  
Fan Kong

A building developed by Wuhan Shimao Group in Wuhan, China, is a high-rise residence with 56 stories near the Yangtze River. The building is a reinforced concrete structure, featuring with a nonregular T-type plane and a height 179.6 m, which is out of the restrictions specified by the China Technical Specification for Concrete Structures of Tall Building (JGJ3-2010). To investigate its seismic performance, a shaking table test with a 1/30 scale model is carried out in Structural Laboratory in Wuhan University of Technology. The dynamic characteristics and the responses of the model subject to different seismic intensities are investigated via the analyzing of shaking table test data and the observed cracking pattern of the scaled model. Finite element analysis of the shaking table model is also established, and the results are coincident well with the test. An autoregressive method is also presented to identify the damage of the structure after suffering from different waves, and the results coincide well with the test and numerical simulation. The shaking table model test, numerical analysis, and damage identification prove that this building is well designed and can be safely put into use. Suggestions and measures to improve the seismic performance of structures are also presented.


Sign in / Sign up

Export Citation Format

Share Document