scholarly journals Bloodstream infection due to Enterobacter ludwigii, correlating with massive aggregation on the surface of a central venous catheter

Infection ◽  
2020 ◽  
Vol 48 (6) ◽  
pp. 955-958
Author(s):  
Lysett Wagner ◽  
Frank Bloos ◽  
Slavena Vylkova

AbstractWe report a case of catheter associated bloodstream infection due to Enterobacter ludwigii with a massive aggregation on the outside surface of a central venous catheter (CVC). The 57 years old patient with a history of spondylodiscitis and Staphylococcus aureus-associated endocarditis was admitted to the intensive care unit for acute cerebral infarction. The patient developed signs of infections and the CVC was removed 11 days after placement. The infectious agent was identified by standard diagnostics to the genus level as belonging to the Enterobacter cloacae complex, and additional molecular testing determined the species as E. ludwigii. The catheter was selected for a study aiming to identify the influence of blood components on the formation of central venous catheter-associated biofilms. In this course a massive biofilm was recognized and is presented here.

2016 ◽  
Vol 29 (6) ◽  
pp. 373
Author(s):  
Jorge Rodrigues ◽  
Andrea Dias ◽  
Guiomar Oliveira ◽  
José Farela Neves

<p><strong>Introduction:</strong> To determine the central-line associated bloodstream infection rate after implementation of central venous catheter-care practice bundles and guidelines and to compare it with the previous central-line associated bloodstream infection rate.<br /><strong>Material and Methods:</strong> A prospective, longitudinal, observational descriptive study with an exploratory component was performed in a Pediatric Intensive Care Unit during five months. The universe was composed of every child admitted to Pediatric Intensive Care Unit who inserted a central venous catheter. A comparative study with historical controls was performed to evaluate the result of the intervention (group 1 <em>versus</em> group 2).<br /><strong>Results:</strong> Seventy five children were included, with a median age of 23 months: 22 (29.3%) newborns; 28 (37.3%) with recent surgery and 32 (43.8%) with underlying illness. A total of 105 central venous catheter were inserted, the majority a single central venous catheter (69.3%), with a mean duration of 6.8 ± 6.7 days. The most common type of central venous catheter was the short-term, non-tunneled central venous catheter (45.7%), while the subclavian and brachial flexure veins were the most frequent insertion sites (both 25.7%). There were no cases of central-line associated bloodstream infection reported during this study. Comparing with historical controls (group 1), both groups were similar regarding age, gender, department of origin and place of central venous catheter insertion. In the current study (group 2), the median length of stay was higher, while the mean duration of central venous catheter (excluding peripherally inserted central line) was similar in both groups. There were no statistical differences regarding central venous catheter caliber and number of lumens. Fewer children admitted to Pediatric Intensive Care Unit had central venous catheter inserted in group 2, with no significant difference between single or multiple central venous catheter.<br /><strong>Discussion:</strong> After multidimensional strategy implementation there was no reported central-line associated bloodstream infection<br /><strong>Conclusions:</strong> Efforts must be made to preserve the same degree of multidimensional prevention, in order to confirm the effective reduction of the central-line associated bloodstream infection rate and to allow its maintenance.</p>


2010 ◽  
Vol 18 (1) ◽  
pp. 73-80 ◽  
Author(s):  
Cibele Grothe ◽  
Angélica Gonçalves da Silva Belasco ◽  
Ana Rita de Cássia Bittencourt ◽  
Lucila Amaral Carneiro Vianna ◽  
Ricardo de Castro Cintra Sesso ◽  
...  

This study evaluated the incidence and risk factors of bloodstream infection (BSI) among patients with a double-lumen central venous catheter (CVC) for hemodialysis (HD) and identified the microorganisms isolated from the bloodstream. A follow-up included all patients (n=156) who underwent hemodialysis by double-lumen CVC at the Federal University of São Paulo - UNIFESP, Brazil, over a one-year period. From the group of patients, 94 presented BSI, of whom 39 had positive cultures at the central venous catheter insertion location. Of the 128 microorganisms isolated from the bloodstream, 53 were S. aureus, 30 were methicillin-sensitive and 23 were methicillin-resistant. Complications related to BSI included 35 cases of septicemia and 27 cases of endocarditis, of which 15 cases progressed to death. The incidence of BSI among these patients was shown to be very high, and this BSI progressed rapidly to the condition of severe infection with a high mortality rate.


PLoS ONE ◽  
2014 ◽  
Vol 9 (4) ◽  
pp. e93898 ◽  
Author(s):  
Walter Zingg ◽  
Vanessa Cartier ◽  
Cigdem Inan ◽  
Sylvie Touveneau ◽  
Michel Theriault ◽  
...  

2007 ◽  
Vol 28 (1) ◽  
pp. 31-35 ◽  
Author(s):  
Francisco Higuera ◽  
Manuel Sigfrido Rangel-Frausto ◽  
Victor Daniel Rosenthal ◽  
Jose Martinez Soto ◽  
Jorge Castañon ◽  
...  

Background.No information is available about the financial impact of central venous catheter (CVC)-associated bloodstream infection (BSI) in Mexico.Objective.To calculate the costs associated with BSI in intensive care units (ICUs) in Mexico City.Design.An 18-month (June 2002 through November 2003), prospective, nested case-control study of patients with and patients without BSI.Setting.Adult ICUs in 3 hospitals in Mexico City.Patients and Methods.A total of 55 patients with BSI (case patients) and 55 patients without BSI (control patients) were compared with respect to hospital, type of ICU, year of hospital admission, length of ICU stay, sex, age, and mean severity of illness score. Information about the length of ICU stay was obtained prospectively during daily rounds. The daily cost of ICU stay was provided by the finance department of each hospital. The cost of antibiotics prescribed for BSI was provided by the hospitals' pharmacy departments.Results.For case patients, the mean extra length of stay was 6.1 days, the mean extra cost of antibiotics was $598, the mean extra hospital cost was $11,591, and the attributable extra mortality was 20%.Conclusions.In this study, the duration of ICU stay for patients with central venous catheter-associated BSI was significantly longer than that for control patients, resulting in increased healthcare costs and a higher attributable mortality. These conclusions support the need to implement preventive measures for hospitalized patients with central venous catheters in Mexico.


2020 ◽  
Vol 2 (1) ◽  
pp. 12
Author(s):  
Gehan A. F. Atia

Context: Central venous access device (CVAD) bundles for insertion and maintenance demonstrate a reduction in the frequency of complications and bloodstream infection when implemented with compliance monitoring, with the reported success of CVAD bundles. Aim: This study aimed to examine the effect of central venous catheter care bundle implementation on outcomes of critically ill patients. Methods: Quasi-experimental research (pre/post-test design) used to achieve the aim of this study. The study conducted at general and surgical intensive care units affiliated to Menoufia University and teaching hospital. Two study samples recruited in this study. All nurses working at the ICUs, as mentioned above, were recruited in this study. They were 6o critical care nurses. A convenient sample of all available critically ill patients at the time of the study was subjected to treatment via a central venous catheter. Four study tools used to collect the data of this study. These are a structured interview questionnaire, CVC nurses’ knowledge assessment questionnaire, nurses’ compliance assessment checklists, and patient complications assessment records. Results: The study result showed a highly statistically significant difference between pre and post-test knowledge scores of studied nurses regarding assisting line insertion, removal, maintenance, care, and infection control practices. Besides, a highly statistically significant difference between pre and post-test scores of nurses’ compliance to central venous catheter care practices of assisting in CVC insertion, blood sample withdrawal, medication and fluid administration, CVP measurements, CVC removal, and the management of central venous line complications. The study also revealed a highly statistically significant difference between the study and control group patients regarding the central venous catheter complications. However, signs of infection were the most frequent complications in both groups. Conclusion. The study concluded that a statistically significant difference between pre and post nurses’ knowledge and compliance with the CVC care bundle. The patients’ outcomes were also improved significantly after the implementation of the CVC care bundle compared to the controls. The study recommended the adoption of the current care bundle that should be disseminated and updated following the international organizations’ recommendation for implementing evidence-based practices for successful central line-associated bloodstream infection (CLABSI) prevention.


Sign in / Sign up

Export Citation Format

Share Document