In vitro method for medical risk assessment of laser fumes

1995 ◽  
Vol 27 (1) ◽  
pp. 39-43
Author(s):  
W. Malkusch ◽  
B. Rehn ◽  
J. Bruch
2020 ◽  
Vol 94 (12) ◽  
pp. 4055-4065
Author(s):  
Emma E. J. Kasteel ◽  
Sandra M. Nijmeijer ◽  
Keyvin Darney ◽  
Leonie S. Lautz ◽  
Jean Lou C. M. Dorne ◽  
...  

Abstract In chemical risk assessment, default uncertainty factors are used to account for interspecies and interindividual differences, and differences in toxicokinetics and toxicodynamics herein. However, these default factors come with little scientific support. Therefore, our aim was to develop an in vitro method, using acetylcholinesterase (AChE) inhibition as a proof of principle, to assess both interspecies and interindividual differences in toxicodynamics. Electric eel enzyme and human blood of 20 different donors (12 men/8 women) were exposed to eight different compounds (chlorpyrifos, chlorpyrifos-oxon, phosmet, phosmet-oxon, diazinon, diazinon-oxon, pirimicarb, rivastigmine) and inhibition of AChE was measured using the Ellman method. The organophosphate parent compounds, chlorpyrifos, phosmet and diazinon, did not show inhibition of AChE. All other compounds showed concentration-dependent inhibition of AChE, with IC50s in human blood ranging from 0.2–29 µM and IC20s ranging from 0.1–18 µM, indicating that AChE is inhibited at concentrations relevant to the in vivo human situation. The oxon analogues were more potent inhibitors of electric eel AChE compared to human AChE. The opposite was true for carbamates, pointing towards interspecies differences for AChE inhibition. Human interindividual variability was low and ranged from 5–25%, depending on the concentration. This study provides a reliable in vitro method for assessing human variability in AChE toxicodynamics. The data suggest that the default uncertainty factor of ~ 3.16 may overestimate human variability for this toxicity endpoint, implying that specific toxicodynamic-related adjustment factors can support quantitative in vitro to in vivo extrapolations that link kinetic and dynamic data to improve chemical risk assessment.


1979 ◽  
Vol 41 (03) ◽  
pp. 576-582
Author(s):  
A R Pomeroy

SummaryThe limitations of currently used in vitro assays of heparin have demonstrated the need for an in vivo method suitable for routine use.The in vivo method which is described in this paper uses, for each heparin preparation, four groups of five mice which are injected intravenously with heparin according to a “2 and 2 dose assay” procedure. The method is relatively rapid, requiring 3 to 4 hours to test five heparin preparations against a standard preparation of heparin. Levels of accuracy and precision acceptable for the requirements of the British Pharmacopoeia are obtained by combining the results of 3 to 4 assays of a heparin preparation.The similarity of results obtained the in vivo method and the in vitro method of the British Pharmacopoeia for heparin preparations of lung and mucosal origin validates this in vivo method and, conversely, demonstrates that the in vitro method of the British Pharmacopoeia gives a reliable estimation of the in vivo activity of heparin.


2001 ◽  
Vol 36 (2) ◽  
pp. 319-330 ◽  
Author(s):  
Mark Servos ◽  
Don Bennie ◽  
Kent Burnison ◽  
Philippa Cureton ◽  
Nicol Davidson ◽  
...  

Abstract A number of biological responses and multigenerational effects, mediated through the disruption of endocrine systems, have been observed in biota exposed to relatively low concentrations of environmental contaminants. These types of responses need to be considered within a weight of evidence approach in our risk assessment and risk management frameworks. However, including endocrine responses in an environmental risk assessment introduces a number of uncertainties that must be considered. A risk assessment of nonylphenol and nonylphenol polyethoxylates (NP/NPE) is used as a case study to demonstrate the sources and magnitude of some of the uncertainties associated with using endocrine disruption as an assessment endpoint. Even with this relatively well studied group of substances, there are substantial knowledge gaps which contribute to the overall uncertainties, limiting the interpretation within the risk assessment. The uncertainty of extrapolating from in vitro or biochemical responses to higher levels of organization or across species is not well understood. The endocrine system is very complex and chemicals can interact or interfere with the normal function of endocrine systems in a number of ways (e.g., receptors, hormones) which may or may not result in an adverse responses in the whole organism. Using endocrine responses can lead to different conclusions than traditional endpoints due to a variety of factors, such as differences in relative potencies of chemicals for specific endpoints (e.g., receptor binding versus chronic toxicity). The uncertainties can also be considerably larger and the desirability of using endocrine endpoints should be carefully evaluated. Endocrine disruption is a mode of action and not a functional endpoint and this needs to be considered carefully in the problem formulation stage and the interpretation of the weight of evidence.


1991 ◽  
Vol 157 (5) ◽  
pp. 1125-1125
Author(s):  
D J Eschelman ◽  
A J Greenfield ◽  
D T Gibbens

Sign in / Sign up

Export Citation Format

Share Document