Rapid X-ray fluorescence analysis of trace metals collected by using naphthalene powder doped with 1-(2-thiazolylazo)-2-naphthol

Talanta ◽  
1979 ◽  
Vol 26 (10) ◽  
pp. 964 ◽  
Author(s):  
T Fujinaga
1989 ◽  
Vol 33 ◽  
pp. 665-670
Author(s):  
William E. Maddox ◽  
Leon Duobinis-Gray ◽  
David A. Owen ◽  
James B. Sickel

Freshwater mussels (Mollusca: Unionidae) are filter feeders that are relatively immobile, widely distributed and are known to concentrate trace metals in their shells (1,2,3). These characteristics make them good candidates for monitoring metal pollution in lakes and rivers. Another characteristic of mussels that make them particularly attractive as pollution monitors is the fact the shell is deposited in distinctive, annual growth layers. The concentrations of metals in these shell layers may provide a history ol the metals present in the environment where the mussel was collected.


1990 ◽  
pp. 665-670
Author(s):  
William E. Maddox ◽  
Leon Duobinis-Gray ◽  
David A. Owen ◽  
James B. Sickel

2006 ◽  
Vol 35 (3) ◽  
pp. 184-189 ◽  
Author(s):  
Wataru Abe ◽  
Satoshi Isaka ◽  
Yuya Koike ◽  
Kazuhiko Nakano ◽  
Kazuhiro Fujita ◽  
...  

Author(s):  
B. J. Panessa ◽  
H. W. Kraner ◽  
J. B. Warren ◽  
K. W. Jones

During photoexcitation the retina requires specific electrolytes and trace metals for optimal function (Na, Mg, Cl, K, Ca, S, P, Cu and Zn). According to Hagins (1981), photoexcitation and generation of a nerve impulse involves the movement of Ca from the rhodopsin-ladened membranes of the rod outer segment (ROS) to the plasmalemma, which in turn decreases the in-flow of Na into the photoreceptor, resulting in hyperpolarization. In toad isolated retinas, the presence of Ba has been found to increase the amplitude and prolong the delay of the light response (Brown and Flaming, 1978). Trace metals such as Cu, Zn and Se are essential for the activity of the metalloenzymes of the retina and retina pigment epithelium (RPE) (i.e. carbonic anhydrase, retinol dehydrogenase, tyrosinase, glutathione peroxidase, superoxide dismutase...). Therefore the content and fluctuations of these elements in the retina and choroid are of fundamental importance for the maintenance of vision. This paper presents elemental data from light and dark adapted frog ocular tissues examined by electron beam induced x-ray microanalysis, x-ray fluorescence spectrometry (XRF) and proton induced x-ray emission spectrometry (PIXE).


Author(s):  
D. A. Carpenter ◽  
M. A. Taylor

The development of intense sources of x rays has led to renewed interest in the use of microbeams of x rays in x-ray fluorescence analysis. Sparks pointed out that the use of x rays as a probe offered the advantages of high sensitivity, low detection limits, low beam damage, and large penetration depths with minimal specimen preparation or perturbation. In addition, the option of air operation provided special advantages for examination of hydrated systems or for nondestructive microanalysis of large specimens.The disadvantages of synchrotron sources prompted the development of laboratory-based instrumentation with various schemes to maximize the beam flux while maintaining small point-to-point resolution. Nichols and Ryon developed a microprobe using a rotating anode source and a modified microdiffractometer. Cross and Wherry showed that by close-coupling the x-ray source, specimen, and detector, good intensities could be obtained for beam sizes between 30 and 100μm. More importantly, both groups combined specimen scanning with modern imaging techniques for rapid element mapping.


Author(s):  
D. A. Carpenter ◽  
Ning Gao ◽  
G. J. Havrilla

A monolithic, polycapillary, x-ray optic was adapted to a laboratory-based x-ray microprobe to evaluate the potential of the optic for x-ray micro fluorescence analysis. The polycapillary was capable of collecting x-rays over a 6 degree angle from a point source and focusing them to a spot approximately 40 µm diameter. The high intensities expected from this capillary should be useful for determining and mapping minor to trace elements in materials. Fig. 1 shows a sketch of the capillary with important dimensions.The microprobe had previously been used with straight and with tapered monocapillaries. Alignment of the monocapillaries with the focal spot was accomplished by electromagnetically scanning the focal spot over the beveled anode. With the polycapillary it was also necessary to manually adjust the distance between the focal spot and the polycapillary.The focal distance and focal spot diameter of the polycapillary were determined from a series of edge scans.


2003 ◽  
Vol 104 ◽  
pp. 435-438 ◽  
Author(s):  
B. S. Twining ◽  
S. B. Baines ◽  
N. S. Fisher ◽  
C. Jacobsen ◽  
J. Maser
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document