A novel method for the rapid determination of chlorin concentrations at high stratigraphic resolution in marine sediments

1995 ◽  
Vol 23 (9) ◽  
pp. 853-856 ◽  
Author(s):  
Philip G. Harris ◽  
James R. Maxwell
1997 ◽  
Vol 42 (4) ◽  
pp. 689-695 ◽  
Author(s):  
Jin-Hua Chen ◽  
Shi-Hui Si ◽  
Li-Hua Nie ◽  
Shou-Zhuo Yao

1983 ◽  
Vol 210 (1) ◽  
pp. 145-155 ◽  
Author(s):  
J W N Akkerman ◽  
G Gorter ◽  
L Schrama ◽  
H Holmsen

A novel method has been developed for rapid and quantitative determination of the rate of energy consumption in platelets. In platelets suspended in a cyanide-containing medium. ATP resynthesis is abruptly blocked by addition of 2-deoxyglucose and D-glucono-1,5-lactone. We demonstrate that the subsequent changes in the levels of cytoplasmic ATP and ADP reflect the velocity of energy consumption in the platelets immediately before addition of the inhibitors. Despite the arrest in ATP resynthesis the platelets remain responsive to stimulation by thrombin (5 units x ml-1) which triggers the secretion of the contents of dense, alpha- and acid hydrolase granules. Unstimulated platelets were found to consume about 3.5 and 0.5 mumol of ATP equivalents x min-1 x (10(11) cells)-1 at 37 degrees C and 15 degrees C, respectively; the thrombin-treated platelets consumed respectively 16 and 2 mumol of ATP equivalents x min-1 x (10(11) cells)-1 at these temperatures. When the velocity of energy consumption was varied by (a) changing the temperature and (b) preincubation with glyco(geno)lytic inhibitors, it was found to be linearly related to the initial rate of secretion from the three types of granules. The precise nature of this relationship differed between the three types of secretion responses and indicated an increasing requirement for metabolic energy for secretion from the three types of granules in the order: dense granule less than alpha-granule less than acid hydrolase granule. The results obtained with changes in temperature were superimposable on those obtained with the glyco(geno)lytic inhibitors for dense granule secretion and alpha-granule secretion, suggesting an apparent coupling between energy consumption and the rate of these secretion responses. The rate of secretion of acid hydrolase was always higher when energy consumption was varied by temperature changes than when glyco(geno)lytic inhibitors were used, probably as a result of metabolic changes prior to induction of secretion. On the basis of these experiments, we calculated an incremental energy consumption during complete secretion of dense, alpha- and acid hydrolase granule contents of 2.5, 4.2 and 6.7 mumol of ATP equivalents x (10(11) platelets)-1, respectively.


2018 ◽  
Vol 29 (6) ◽  
pp. 1609-1613 ◽  
Author(s):  
Dana V. Rizk ◽  
Daniel Meier ◽  
Ruben M. Sandoval ◽  
Teresa Chacana ◽  
Erinn S. Reilly ◽  
...  

Background Direct quantitative measurement of GFR (mGFR) remains a specialized task primarily performed in research settings. Multiple formulas for estimating GFR have been developed that use the readily available endogenous biomarkers creatinine and/or cystatin C. However, eGFR formulas have limitations, and an accurate mGFR is necessary in some clinical situations and for certain patient populations. We conducted a prospective, open-label study to evaluate a novel rapid technique for determining plasma volume and mGFR.Methods We developed a new exogenous biomarker, visible fluorescent injectate (VFI), consisting of a large 150-kD rhodamine derivative and small 5-kD fluorescein carboxymethylated dextrans. After a single intravenous injection of VFI, plasma volume and mGFR can be determined on the basis of the plasma pharmacokinetics of the rhodamine derivative and fluorescein carboxymethylated dextrans, respectively. In this study involving 32 adults with normal kidney function (n=16), CKD stage 3 (n=8), or CKD stage 4 (n=8), we compared VFI-based mGFR values with values obtained by measuring iohexol plasma disappearance. VFI-based mGFR required three 0.5-ml blood draws over 3 hours; iohexol-based mGFR required five samples taken over 6 hours. Eight healthy participants received repeat VFI injections at 24 hours.Results VFI-based mGFR values showed close linear correlation with the iohexol-based mGFR values in all participants. Injections were well tolerated, including when given on consecutive days. No serious adverse events were reported. VFI-based mGFR was highly reproducible.Conclusions The VFI-based approach allows for the rapid determination of mGFR at the bedside while maintaining patient safety and measurement accuracy and reproducibility.


2018 ◽  
Vol 73 (3) ◽  
pp. 236-242 ◽  
Author(s):  
L. V. Zrelova ◽  
E. I. Belyaeva ◽  
D. Yu. Marchenko ◽  
E. A. Ivanova ◽  
D. A. Sandzhieva ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document