Constructal wavy-fin channels of a compact heat exchanger with heat transfer rate maximization and pressure losses minimization

2015 ◽  
Vol 75 ◽  
pp. 24-32 ◽  
Author(s):  
Yidan Song ◽  
Masoud Asadi ◽  
Gongnan Xie ◽  
L.A.O. Rocha
2013 ◽  
Vol 388 ◽  
pp. 149-155 ◽  
Author(s):  
Mazlan Abdul Wahid ◽  
Ahmad Ali Gholami ◽  
H.A. Mohammed

In the present work, laminar cross flow forced convective heat transfer of nanofluid over tube banks with various geometry under constant wall temperature condition is investigated numerically. We used nanofluid instead of pure fluid ,as external cross flow, because of its potential to increase heat transfer of system. The effect of the nanofluid on the compact heat exchanger performance was studied and compared to that of a conventional fluid.The two-dimensional steady state Navier-Stokes equations and the energy equation governing laminar incompressible flow are solved using a Finite volume method for the case of flow across an in-line bundle of tube banks as commercial compact heat exchanger. The nanofluid used was alumina-water 4% and the performance was compared with water. In this paper, the effect of parameters such as various tube shapes ( flat, circle, elliptic), and heat transfer comparison between nanofluid and pure fluid is studied. Temperature profile, heat transfer coefficient and pressure profile were obtained from the simulations and the performance was discussed in terms of heat transfer rate and performance index. Results indicated enhanced performance in the use of a nanofluid, and slight penalty in pressure drop. The increase in Reynolds number caused an increase in the heat transfer rate and a decrease in the overall bulk temperature of the cold fluid. The results show that, for a given heat duty, a mas flow rate required of the nanofluid is lower than that of water causing lower pressure drop. Consequently, smaller equipment and less pumping power are required.


2021 ◽  
Vol 25 (2 Part B) ◽  
pp. 1545-1559
Author(s):  
Tarkan Koca ◽  
Aydın Citlak

In this study, the effects of rotating straight and helical inner tubes is experimentally discussed to determine heat transfer and pressure losses in rotating tubes and improve heat transfer. The outer tube remains stationary and the inner tube is rotated at different speeds in the work. In the experiments for straight and helical tubes, the flow regime is turbulent. According to the results, Nusselt number, pressure loss, and efficiency of heat exchanger were gauged. In addition, empirical formulas were obtained for each pipe type. It is observed that as the rotation speed of the pipe increases, the heat transfer rate increases. The pipe that provides the best increase in heat transfer is the five helixes tubes. At five helixes tubes; after the number of revolutions per minute exceeds 300, the increase in heat transfer rate has almost halt. At five helixes tubes and at 300 rpm speed when the flow of cold water through the annular gap with the fluid passing through the inner tube is equal, the heat transfer increases by 124.10% compared to straight tube, 23.47% compared to two helixes tubes, 7.92% compared to three helixes tubes, and 1.65% compared to four helixes tubes. Maximum effectiveness was obtained while rotating with 300 rpm in five helixes pipes.


2018 ◽  
Vol 16 (2) ◽  
pp. 233 ◽  
Author(s):  
Seyed Alireza Ghazanfari ◽  
Malan Abdul Wahid

Heat transfer rate, pressure loss and efficiency are considered as the most important parameters in designing compact heat exchangers. Despite different types of heat exchangers, fin-and-tube compact heat exchangers are still common device in different industries due to the diversity of usage and the low space installation need. The efficiency of the compact heat exchanger can be increased by introducing the fins and increasing the heat transfer rate between the surface and the surroundings. Numerous modifications can be applied to the fin surface to increase heat transfer. Delta-winglet vortex generators (VGs) are known to enhance the heat transfer between the energy carrying fluid and the heat transfer surfaces in plate-fin-and-tube banks, but they have drawbacks as well. They increase the pressure loss and this should be considered. In this paper, the thermal efficiency of compact heat exchanger with VGs is investigated in different variations. The angle of attack, the length and horizontal and vertical position of winglet are the main parameters to consider. Numerical analyses are carried out to examine finned tube heat exchanger with winglets at the fin surface in a relatively low Reynolds number flow for the inline tube arrangements. The results showed that the length of the winglet significantly affects the improvement of heat transfer performance of the fin-and-tube compact heat exchangers with a moderate pressure loss penalty. In addition, the results show that the optimization cannot be performed for one criterion only. More parameters should be considered at the same time to run the process properly and improve the heat exchanger efficiency.


2013 ◽  
Vol 448-453 ◽  
pp. 3259-3269
Author(s):  
Zhi Wei Li ◽  
Hong Zhou He ◽  
Huang Huang Zhuang

The characteristics of the external heat exchanger (EHE) for a 4 MWth circulation fluidized bed combustor were studied in the present paper. The length, width and height of EHE were 1.5 m, 0.8 m and 9 m, respectively. The circulating ash flow passing the heating surface bed could be controlled by adjusting the fluidizing air flow and the heating transferred from the circulating ash to the cooling water. The ash flow rate passing through the heat transfer bed was from 0.4 to 2.2 kg/s. The ash average temperature was from 500 to 750 °C. And the heat transfer rate between the ash and the cooling water was between 150 and 300 W/(m2·°C). The relationships among the circulating ash temperature, the heat transfer, heat transfer rate, the heat transfer coefficient and the circulating ash flow passing through the heating exchange cell were also presented and could be used for further commercial EHE design.


2021 ◽  
Vol 34 (02) ◽  
Author(s):  
Mohammad Sikindar Baba ◽  
◽  
Oddarapu Kalyani ◽  

2020 ◽  
Vol 12 (18) ◽  
pp. 7345
Author(s):  
Linlin Zhang ◽  
Zhonghua Shi ◽  
Tianhao Yuan

In this paper, a dynamic heat transfer model for the vertical double U-tube borehole heat exchanger (BHE) was developed to comprehensively address the coupled heat transfer between the in-tube fluid and the soil with groundwater advection. A new concept of the heat transfer effectiveness was also proposed to evaluate the BHE heat exchange performance together with the index of the heat transfer rate. The moving finite line heat source model was selected for heat transfer outside the borehole and the steady-state model for inside the borehole. The data obtained in an on-site thermal response test were used to validate the physical model of the BHE. Then, the effects of soil type, groundwater advection velocity, inlet water flow rate, and temperature on the outlet water temperature of BHE were explored. Results show that ignoring the effects of groundwater advection in sand gravel may lead to deviation in the heat transfer rate of up to 38.9% of the ground loop design. The groundwater advection fosters the heat transfer of BHE. An increase in advection velocity may also help to shorten the time which takes the surrounding soil to reach a stable temperature. The mass flow rate of the inlet water to the BHE should be more than 0.5 kg·s−1 but should not exceed a certain upper limit under the practical engineering applications with common scale BHE. The efficiency of the heat transfer of the double U-tube BHE was determined jointly by factors such as the soil’s physical properties and the groundwater advection velocity.


Author(s):  
Jieun Hwang ◽  
Keumnam Cho

Heat exchanger experiences frost on its surface when it operates below 0°C under heating condition of the heat pump. Since frost blocks air flow through the fin tube heat exchanger, it increases air-side pressure drop and deteriorates heat transfer rate of the heat exchanger. Prediction of the frost profiles on the heat exchanger is needed to minimize the unfavorable effect on the heat exchanger by frost. The present study predicts non-uniform frost distribution on the surface of fin-tube heat exchanger and shows its accuracy by comparing with measured profiles. Fin and tube heat exchanger for heat pump was considered for the frost prediction under practical refrigerant and air conditions. Non-uniform frost pattern was predicted by using segment by segment method of the heat exchanger. Heat transfer rate and exit temperature of air and refrigerant for each segment were calculated by applying ε-NTU method. Air volume flow rate in the front of the heat exchanger was decreased as frost goes on. It was utilized for the prediction of the frost formation. Numerically predicted results were compared with measured local data. They agreed within ±10.4% under the ISO 5151 condition.