A method for two-dimensional temperature field distribution reconstruction

2017 ◽  
Vol 111 ◽  
pp. 961-967 ◽  
Author(s):  
Ruixi Jia ◽  
Qingyu Xiong ◽  
Guangyu Xu ◽  
Kai Wang ◽  
Shan Liang
Author(s):  
Junfan Chen ◽  
Ning Sun ◽  
Zhongxie Jin

Spatial resolution is an important parameter that characterizes the detection capability of a system, and there are extremely high requirements for spatial resolution in important fields such as the fossil energy industry and nuclear industry. In order to realize the high-precision distributed monitoring of the optical fiber distributed temperature sensing system (DTS), the factors affecting the spatial resolution of the DTS system were analyzed, and a two-dimensional planar temperature field distribution monitoring scheme based on Raman distributed temperature sensor (RDTS) was proposed. In this scheme, based on the layout of the two-dimensional RDTS heat source positioning system, multimode fiber was adopted. After comparing several sensing fiber routing schemes, the 45∘ skew 2D wiring method of sensing fiber was finally selected. According to the experimental results, the spatial resolution of the temperature field distribution in the monitoring area can break through the limitation of the system resolution. It has more application value than the traditional one-dimensional distributed temperature sensing system.


Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1792
Author(s):  
Bingbing Dong ◽  
Yu Gu ◽  
Changsheng Gao ◽  
Zhu Zhang ◽  
Tao Wen ◽  
...  

In recent years, the new type design of current transformer with bushing structure has been widely used in the distribution network system due to its advantages of miniaturization, high mechanical strength, maintenance-free, safety and environmental protection. The internal temperature field distribution is an important characteristic parameter to characterize the thermal insulation and aging performance of the transformer, and the internal temperature field distribution is mainly derived from the joule heat generated by the primary side guide rod after flowing through the current. Since the electric environment is a transient field and the thermal environment changes slowly with time as a steady field under the actual conditions, it is more complex and necessary to study the electrothermal coupling field of current transformer (CT). In this paper, a 3D simulation model of a new type design of current transformer for distribution network based on electric-thermal coupling is established by using finite element method (FEM) software. Considering that the actual thermal conduction process of CT is mainly by conduction, convection and radiation, three different kinds of boundary conditions such as solid heat transfer boundary condition, heat convection boundary condition and surface radiation boundary condition are applied to the CT. Through the model created above, the temperature rise process and the distribution characteristics of temperature gradient of the inner conductor under different current, different ambient temperatures and different core diameters conditions are studied. Meanwhile, the hottest temperature and the maximum temperature gradient difference are calculated. According to this, the position of weak insulation of the transformer is determined. The research results can provide a reference for the factory production of new type design of current transformer.


AIP Advances ◽  
2016 ◽  
Vol 6 (7) ◽  
pp. 075007 ◽  
Author(s):  
Ruixi Jia ◽  
Qingyu Xiong ◽  
Kai Wang ◽  
Lijie Wang ◽  
Guangyu Xu ◽  
...  

2021 ◽  
Vol 315 ◽  
pp. 3-9
Author(s):  
Yuan Gao ◽  
Li Hua Zhan ◽  
Hai Long Liao ◽  
Xue Ying Chen ◽  
Ming Hui Huang

The uniformity of temperature field distribution in creep aging process is very important to the forming accuracy of components. In this paper, the temperature field distribution of 2219 aluminum alloy tank cover during aging forming is simulated by using the finite element software FLUENT, and a two-stage heating process is proposed to reduce the temperature field distribution heterogeneity. The results show that the temperature difference of the tank cover is large in the single-stage heating process, and the maximum temperature difference is above 27°C,which seriously affects the forming accuracy of the tank cover. With two-stage heating process, the temperature difference in the first stage has almost no direct impact on the forming accuracy of the top cover. In the second stage, the temperature difference of the tank cover is controlled within 10°C, compared with the single-stage heating, the maximum temperature difference is reduced by more than 17°C. The two-stage heating effectively reduces the heterogeneity of the temperature field of the top cover. The research provides technical support for the precise thermal mechanical coupling of large-scale creep aging forming components.


Sign in / Sign up

Export Citation Format

Share Document