Inguinoscrotal Pathology on Computed Tomography: An Alternative Perspective

2016 ◽  
Vol 67 (3) ◽  
pp. 225-233 ◽  
Author(s):  
Isaac Daimiel Naranjo ◽  
Andrea Alcalá-Galiano Rubio

Computed tomography (CT) is not the imaging technique of choice to assess inguinoscrotal pathology, as magnetic resonance or ultrasonography have superior soft tissue contrast resolution and do not involve gonadal exposure to ionizing radiation. However, testicular and inguinoscrotal pathology may be found both as an extension of intra-abdominal processes or incidentally on CT scans requested for other reasons. CT also plays a role in the evaluation of testicular injury when associated to pelvic trauma and in perineal infections with scrotal extension. A pictorial review of testicular and inguinoscrotal involvement in vascular, neoplastic, traumatic, infectious, or inflammatory diseases and in complications of abdominal surgeries is presented. Additionally, the CT appearance of several congenital anomalies and benign processes is depicted.

Foot & Ankle ◽  
1988 ◽  
Vol 8 (6) ◽  
pp. 297-307 ◽  
Author(s):  
Zehava Sadka Rosenberg ◽  
Yvonne Cheung ◽  
Melvin H. Jahss

CT and MRI are both effective in the diagnosis of ankle tendon injuries. MRI is the preferred study, however, because of its superior soft tissue contrast resolution, multiplanar capabilities, lack of beam hardening artifacts, and lack of ionizing radiation. CT can serve as an excellent substitute when financial considerations and availability preclude the use of MRI. CT is also superior in evaluating bony abnormalities associated with tendon injuries.


Imaging ◽  
2021 ◽  
Author(s):  
Cesare Mantini ◽  
Francesco Corradi ◽  
Domenico Mastrodicasa ◽  
Luca Procaccini ◽  
Marzia Olivieri ◽  
...  

SUMMARYThe pericardial cavity, sinuses, and recesses are frequently depicted on Computed Tomography (CT) and Magnetic Resonance (MR).We here review the normal human pericardial structures as provided by MR imaging of young, healthy subject and CT scans acquired after iatrogenic coronary dissection. We compared such radiological information with cadaveric axial and sagittal sections of the human body provided by the Visible Human Server (VHS), Ecole Polytechnique Federale de Lousanne (EPFL), Switzerland.


Author(s):  
Maria Gabriella Brizi ◽  
Federica Perillo ◽  
Federico Cannone ◽  
Laura Tuzza ◽  
Riccardo Manfredi

AbstractAcute pancreatitis is one of the most commonly encountered etiologies in the emergency setting, with a broad spectrum of findings that varies in severity from mild interstitial pancreas to severe forms with significant local and systemic complications that are associated with a substantial degree of morbidity and mortality. In this article the radiological aspect of the terminology and classification of acute pancreatitis are reviewed. The roles of ultrasound, computed tomography, and magnetic resonance imaging in the diagnosis and evaluation of acute pancreatitis and its complications are discussed. The authors present a practical image-rich guide, applying the revised Atlanta classification system, with the goal of facilitating radiologists to write a correct report, and reinforcing the radiologist’s role as a key member of a multidisciplinary team in treating patients with acute pancreatitis. Computed tomography is the most performed imaging test for acute pancreatitis. Nevertheless, MRI is useful in many specific situations, due to its superiority soft tissue contrast resolution and better assessment of biliary and pancreatic duct, for example in the ductal disconnection. The purpose if this article is to review recent advances in imaging acquisition and analytic techniques in the evaluation of AP.


Author(s):  
H.W. Deckman ◽  
B.F. Flannery ◽  
J.H. Dunsmuir ◽  
K.D' Amico

We have developed a new X-ray microscope which produces complete three dimensional images of samples. The microscope operates by performing X-ray tomography with unprecedented resolution. Tomography is a non-invasive imaging technique that creates maps of the internal structure of samples from measurement of the attenuation of penetrating radiation. As conventionally practiced in medical Computed Tomography (CT), radiologists produce maps of bone and tissue structure in several planar sections that reveal features with 1mm resolution and 1% contrast. Microtomography extends the capability of CT in several ways. First, the resolution which approaches one micron, is one thousand times higher than that of the medical CT. Second, our approach acquires and analyses the data in a panoramic imaging format that directly produces three-dimensional maps in a series of contiguous stacked planes. Typical maps available today consist of three hundred planar sections each containing 512x512 pixels. Finally, and perhaps of most import scientifically, microtomography using a synchrotron X-ray source, allows us to generate maps of individual element.


2019 ◽  
Vol 65 (4) ◽  
pp. 590-595
Author(s):  
Arkadiy Naumenko ◽  
Kseniya Sapova ◽  
Oleg Konoplev ◽  
Svetlana Astashchenko ◽  
Igor Chernushevich

Precise localization and excision of the originating site of a sinonasal inverted papilloma is essential for decreasing tumor recurrence. In this study we evaluated the use of preoperative computed tomography (CT) to pinpoint the attachment/origi-nating sites of the tumor.


2019 ◽  
Vol 12 (S 01) ◽  
pp. S39-S44
Author(s):  
Michael Okoli ◽  
Kevin Lutsky ◽  
Michael Rivlin ◽  
Brian Katt ◽  
Pedro Beredjiklian

Abstract Introduction The purpose of this study is to determine the radiographic dimensions of the finger metacarpals and to compare these measurements with headless compression screws commonly used for fracture fixation. Materials and Methods We analyzed computed tomography (CT) scans of the index, long, ring, and small metacarpal bones and measured the metacarpal length, distance from the isthmus to the metacarpal head, and intramedullary diameter of the isthmus. Metacarpals with previous fractures or hardware were excluded. We compared these dimensions with the size of several commercially available headless screws used for intramedullary fixation. Results A total of 223 metacarpals from 57 patients were analyzed. The index metacarpal was the longest, averaging 67.6 mm in length. The mean distance from the most distal aspect of the metacarpal head to the isthmus was 40.3, 39.5, 34.4, and 31 mm for the index, long, ring, and small metacarpals, respectively. The narrowest diameter of the isthmus was a mean of 2.6, 2.7, 2.3, and 3 mm for the index, long, ring, and small metacarpals, respectively. Of 33 commercially available screws, only 27% percent reached the isthmus of the index metacarpal followed by 42, 48, and 58% in the long, ring, and small metacarpals, respectively. Conclusion The index and long metacarpals are at a particular risk of screw mismatch given their relatively long lengths and narrow isthmus diameters.


2021 ◽  
Vol 10 (11) ◽  
pp. 2456
Author(s):  
Raminta Luksaite-Lukste ◽  
Ruta Kliokyte ◽  
Arturas Samuilis ◽  
Eugenijus Jasiunas ◽  
Martynas Luksta ◽  
...  

(1) Background: Diagnosis of acute appendicitis (AA) remains challenging; either computed tomography (CT) is universally used or negative appendectomy rates of up to 30% are reported. Transabdominal ultrasound (TUS) as the first-choice imaging modality might be useful in adult patients to reduce the need for CT scans while maintaining low negative appendectomy (NA) rates. The aim of this study was to report the results of the conditional CT strategy for the diagnosis of acute appendicitis. (2) Methods: All patients suspected of acute appendicitis were prospectively registered from 1 January 2016 to 31 December 2018. Data on their clinical, radiological and surgical outcomes are presented. (3) Results: A total of 1855 patients were enrolled in our study: 1206 (65.0%) were women, 649 (35.0%) were men, and the median age was 34 years (IQR, 24.5–51). TUS was performed in 1851 (99.8%) patients, and CT in 463 (25.0%) patients. Appendices were not visualized on TUS in 1320 patients (71.3%). Furthermore, 172 (37.1%) of 463 CTs were diagnosed with AA, 42 (9.1%) CTs revealed alternative emergency diagnosis and 249 (53.8%) CTs were normal. Overall, 519 (28.0%) patients were diagnosed with AA: 464 appendectomies and 27 diagnostic laparoscopies were performed. The NA rate was 4.2%. The sensitivity and specificity for TUS and CT are as follows: 71.4% and 96.2%; 93.8% and 93.6%. (4) Conclusion: A conditional CT strategy is effective in reducing NA rates and avoids unnecessary CT in a large proportion of patients. Observation and repeated TUS might be useful in unclear cases.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Petri Paakkari ◽  
Satu I. Inkinen ◽  
Miitu K. M. Honkanen ◽  
Mithilesh Prakash ◽  
Rubina Shaikh ◽  
...  

AbstractPhoton-counting detector computed tomography (PCD-CT) is a modern spectral imaging technique utilizing photon-counting detectors (PCDs). PCDs detect individual photons and classify them into fixed energy bins, thus enabling energy selective imaging, contrary to energy integrating detectors that detects and sums the total energy from all photons during acquisition. The structure and composition of the articular cartilage cannot be detected with native CT imaging but can be assessed using contrast-enhancement. Spectral imaging allows simultaneous decomposition of multiple contrast agents, which can be used to target and highlight discrete cartilage properties. Here we report, for the first time, the use of PCD-CT to quantify a cationic iodinated CA4+ (targeting proteoglycans) and a non-ionic gadolinium-based gadoteridol (reflecting water content) contrast agents inside human osteochondral tissue (n = 53). We performed PCD-CT scanning at diffusion equilibrium and compared the results against reference data of biomechanical and optical density measurements, and Mankin scoring. PCD-CT enables simultaneous quantification of the two contrast agent concentrations inside cartilage and the results correlate with the structural and functional reference parameters. With improved soft tissue contrast and assessment of proteoglycan and water contents, PCD-CT with the dual contrast agent method is of potential use for the detection and monitoring of osteoarthritis.


Medicina ◽  
2021 ◽  
Vol 57 (1) ◽  
pp. 63
Author(s):  
Sung Nam Moon ◽  
Jung-Soo Pyo ◽  
Wu Seong Kang

Background and objective: The early detection of underlying hemorrhage of pelvic trauma has been a critical issue. The aim of this study was to systematically determine the diagnostic accuracy of computed tomography (CT) for detecting severe pelvic hemorrhage. Materials and Methods: Relevant articles were obtained by searching PubMed, EMBASE, and Cochrane databases through 28 November 2020. Diagnostic test accuracy results were reviewed to obtain the sensitivity, specificity, diagnostic odds ratio, and summary receiver operating characteristic curve of CT for the diagnosis in pelvic trauma patients. The positive finding on CT was defined as the contrast extravasation. As the reference standard, severe pelvic hemorrhage was defined as an identification of bleeding at angiography or by direct inspection using laparotomy that required hemostasis by angioembolization or surgery. A subgroup analysis was performed according to the CT modality that is divided by the number of detector rows. Result: Thirteen eligible studies (29 subsets) were included in the present meta-analysis. Pooled sensitivity of CT was 0.786 [95% confidence interval (CI), 0.574–0.909], and pooled specificity was 0.944 (95% CI, 0.900–0.970). Pooled sensitivity of the 1–4 detector row group and 16–64 detector row group was 0.487 (95% CI, 0.215–0.767) and 0.915 (95% CI, 0.848–0.953), respectively. Pooled specificity of the 1–4 and 16–64 detector row groups was 0.956 (95% CI, 0.876–0.985) and 0.906 (95% CI, 0.828–0.951), respectively. Conclusion: Multi-detector CT with 16 or more detector rows has acceptable high sensitivity and specificity. Extravasation on CT indicates severe hemorrhage in patients with pelvic trauma.


Sign in / Sign up

Export Citation Format

Share Document