Analysis of interchangeability and indirect reference ranges of sodium, potassium, glucose, lactate and hemoglobin measured on point of care and central laboratory analyzers

2019 ◽  
Vol 493 ◽  
pp. S667-S668
Author(s):  
M. Kocijancic ◽  
F.B. Kraus ◽  
B. Ludwig-Kraus
2020 ◽  
Vol 19 (1) ◽  
pp. 4-14
Author(s):  
Jan Y Verbakel ◽  
◽  
Charlotte Richardson ◽  
Tania Elias ◽  
Jordan Bowen ◽  
...  

Objective: To ensure clinicians can rely on point-of-care testing results, we assessed agreement between point-of-care tests for creatinine, urea, sodium, potassium, calcium, Hb, INR, CRP and subsequent corresponding laboratory tests. Participants: Community-dwelling adults referred to a community-based acute ambulatory care unit. Interventions: The Abbott i-STATTM (Hb, clinical chemistry, INR) and the AfinionTM Analyser (CRP) and corresponding laboratory analyses. Outcomes: Agreement (Bland-Altman) and bias (Passing-Bablok regression). Results: Among 462 adults we found an absolute mean difference between point-of-care and central laboratory analyses of 6.4g/L (95%LOA -7.9 to +20.6) for haemoglobin, -0.5mmol/L (95%LOA -4.5 to +3.5) for sodium, 0.2mmol/L (95%LOA -0.6 to +0.9) for potassium, 0.0mmol/L (95%LOA -0.3 to +0.3) for calcium, 9.0 μmol/L (95%LOA -18.5 to +36.4) for creatinine, 0.0mmol/L (95%LOA -2.7 to +2.6) for urea, -0.2 (95%LOA -2.4 to +2.0) for INR, -5.0 mg/L (95%LOA -24.4 to +14.4) for CRP. Conclusions: There was acceptable agreement and bias for these analytes, except for haemoglobin and creatinine.


Author(s):  
Ha-young Choi ◽  
William Corder ◽  
Eshetu Tefera ◽  
Kabir M. Abubakar

Objective Electrolyte, hemoglobin, and bilirubin values are routinely reported with point-of-care (POC) testing for blood gases. Results are rapidly available and require a small blood volume. Yet, these results are underutilized due to noted discrepancies between central laboratory (CL) and POC testing. The study aimed to determine the correlation between POC and CL measurement of electrolytes, hemoglobin, and bilirubin in neonates. Study Design Electrolyte, hemoglobin, and bilirubin results obtained from capillary blood over a 4-month period were analyzed. Each CL value was matched with a POC value from the same sample or another sample less than 1-hour apart. Agreement was determined by measuring the mean difference (MD) between paired samples with 95% limits of agreement (LOA) and Lin's concordance correlation (LCC). Results There were 355-paired sodium/potassium, 139 paired hemoglobin, and 197 paired bilirubin values analyzed. POC sodium values were lower (133.5 ± 5.8 mmol/L) than CL (140.2 ± 5.8 mmol/L), p <0.00001 with poor agreement (LCC = 0.49; MD = 6.7; 95% LOA: −13.6 to 0.14). POC potassium values were lower (4.6 ± 0.98 mmol/L) than CL (4.98 ± 1.24mEq/L), p < 0.0001, but with better concordance and agreement. (LCC = 0.6; MD = 0.4; 95% LOA: −2.3 to 1.4). There were no differences in hemoglobin between POC (14.3 ± 3.2 g/dL) and CL (14.4 ± 3.1 g/dL), p = 0.2 with good LCC (0.93) and in bilirubin values between POC (6.0 ± 3.2 mg/dL) and CL (5.8 ± 3.0 mg/dL), MD = 0.18, and p = 0.07. Conclusion POC Sodium values are lower than CL. POC potassium levels are also lower, but the differences may not be clinically important while hemoglobin and bilirubin levels are similar between POC and CL. As POC potassium, hemoglobin, and bilirubin levels closely reflect CL values, these results can be relied upon to make clinical judgments in neonates. Key Points


2021 ◽  
Author(s):  
Jenifer Gómez-Pastora ◽  
James Kim ◽  
Mitchell Weigand ◽  
Andre F. Palmer ◽  
Mark Yazer ◽  
...  

Abstract Anemia and iron deficiency continue to be the most prevalent nutritional disorders in the world, affecting billions of people in both developed and developing countries. The initial diagnosis of anemia is typically based on several markers, including red blood cell (RBC) count, hematocrit and total hemoglobin. Using modern hematology analyzers, erythrocyte parameters such as mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), etc. are also being used. However, most of these commercially available analyzers pose several disadvantages: they are expensive instruments that require significant bench space and are heavy enough to limit their use to a specific lab and leading to a delay in results, making them less practical as a point-of-care instrument that can be used for swift clinical evaluation. Thus, there is a need for a portable and economical hematology analyzer that can be used at the point of need. In this work, we evaluated the performance of a system referred to as the cell tracking velocimetry (CTV) to measure several hematological parameters from fresh human blood obtained from healthy donors. Our system, based on the paramagnetic behavior that methemoglobin containing RBCs experience when suspended in water after applying a magnetic field, uses a combination of magnets and microfluidics and has the ability to track the movement of thousands of red cells in a short period of time. This allows us to measure not only traditional RBC indices but also novel parameters that are only available for analyzers that assess erythrocytes on a cell by cell basis. As such, we report, for the first time, the use of our CTV as a hematology analyzer that is able to measure red cell volume or MCV, red cell hemoglobin mass or MCH, hemoglobin concentration (MCHC), red cell distribution width (RDW) and the percentage of hypochromic cells, which is an indicator of insufficient marrow iron supply that reflects recent iron reduction. Our initial results indicate that most of the parameters measured with CTV are within the normal range for healthy adults. Only the parameters related to the red cell volume (primarily MCV and RDW) were outside the normal range. We observed significant discrepancies between the MCV measured by our technology (and also by an automated cell counter) and the manual MCV measured through the hematocrit obtained by packed cell volume method, which are attributed to the artifacts of plasma trapping and cell shrinkage. While there may be limitations for measuring MCV, this device offers a novel point of care instrument to provide rapid RBC parameters such as iron stores that are otherwise not rapidly available to the clinician. Thus, our CTV is a promising technology with the potential to be employed as an accurate, economical, portable and fast hematology analyzer after applying instrument-specific reference ranges or correction factors.


Author(s):  
Chin-Pin Yeo ◽  
Carol Hui-Chen Tan ◽  
Edward Jacob

Background Point-of-care-testing (POCT) of haemoglobin Alc (HbA1c) is popular due to its fast turnaround of results in the outpatient setting. The aim of this project was to evaluate the performance of a new HbA1c POCT analyser, the Bio-Rad in2it, and compare it with the Siemens DCA 2000, Bio-Rad Variant II and Roche Tina-quant HbA1c Gen 2 assay on the cobas c501. Methods Imprecision of the four methods were compared by computing total imprecision from within-run and between-run data. A total of 80 samples were also compared and analysed by Deming regression and Altman–Bland difference test. Results Study of total imprecision of the in2it at HBA1c levels of 6.0% and 10.4% produced a coefficient of variation (%CV) of 3.8% and 3.7%, respectively. These results were more favourable as compared with the DCA 2000 but did not match the low imprecision of the central laboratory methods, the Bio-Rad Variant II and the Roche cobas c501. Comparison between the in2it and the central laboratory analysers, Bio-Rad variant II and cobas c501, revealed positive bias of 12% and 10%, respectively, supported by corresponding Deming regression equation slopes of +1.18 and +1.14. Comparison between the DCA 2000 and the central laboratory analysers revealed a bias that became increasingly positive with rising HbA1c concentrations with Deming regression analysis also revealing proportional and constant differences. Conclusions The in2it is a suitable POCT analyser for HbA1c but its less than ideal precision performance and differences with the central laboratory analysers must be communicated to and noted by the users.


1996 ◽  
Vol 42 (5) ◽  
pp. 711-717 ◽  
Author(s):  
C A Parvin ◽  
S F Lo ◽  
S M Deuser ◽  
L G Weaver ◽  
L M Lewis ◽  
...  

Abstract We prospectively investigated whether routine use of a point-of-care testing (POCT) device by nonlaboratory operators in the emergency department (ED) for all patients requiring the available tests could shorten patient length of stay (LOS) in the ED. ED patient LOS, defined as the length of time between triage (initial patient interview) and discharge (released to home or admitted to hospital), was examined during a 5-week experimental period in which ED personnel used a hand-held POCT device to perform Na, K, Cl, glucose (Gluc), and blood urea nitrogen (BUN) testing. Preliminary data demonstrated acceptable accuracy of the hand-held device. Patient LOS distribution during the experimental period was compared with the LOS distribution during a 5-week control period before institution of the POCT device and with a 3-week control period after its use. Among nearly 15 000 ED patient visits during the study period, 4985 patients (2067 during the experimental period and 2918 during the two control periods) had at least one Na, K, Cl, BUN, or Gluc test ordered from the ED. However, no decrease in ED LOS was observed in the tested patients during the experimental period. Median LOS during the experimental period was 209 min vs 201 min for the combined control periods. Stratifying patients by presenting condition (chest pain, trauma, etc.), discharge/admit status, or presence/absence of other central laboratory tests did not reveal a decrease in patient LOS for any patient subgroup during the experimental period. From these observations, we consider it unlikely that routine use of a hand-held POCT device in a large ED such as ours is sufficient by itself to impact ED patient LOS.