Molecular recognition triggered aptazyme cascade for ultrasensitive detection of exosomes in clinical serum samples

Author(s):  
Kemei Jiang ◽  
Yanan Wu ◽  
Juan Chen ◽  
Mingqing Shi ◽  
Hong-Min Meng ◽  
...  
2018 ◽  
Vol 1038 ◽  
pp. 112-119 ◽  
Author(s):  
Yaofeng Zhou ◽  
Xiaolin Huang ◽  
Sicheng Xiong ◽  
Xiangmin Li ◽  
Shengnan Zhan ◽  
...  

2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Wei Yang ◽  
Zheng Zhou ◽  
Haiping Wu ◽  
Changjin Liu ◽  
Bo Shen ◽  
...  

Abstract Background Anti-myeloperoxidase antibody (anti-MPO) is an important biomarker for anti-neutrophil cytoplasm antibody (ANCA)-associated vasculitides (AAVs). However, the complicated operation procedures and insufficient sensitivity of conventional anti-MPO detection methods limit their application in monitoring efficacy of AAVs in clinical diagnosis. Herein, a dual amplified electrochemiluminescence (ECL) immunosensor based on multi-function PtCo nanozymes/CdS nanocrystals@graphene oxide (PtCo/CdS@GO) luminophores and K2S2O8/H2O2 coreactants has been fabricated for ultrasensitive detection of anti-MPO. Results PtCo/CdS@GO luminophores as novel signal amplification labels and nanocarriers to load rabbit anti-mouse IgG were synthesized by co-doping with Pt and Co nanozymes simultaneously with several considerable advantages, including astonishing peroxidase-like catalytic activity, high-efficiency luminescence performance and superior stability in aqueous solutions. Meanwhile, upon the K2S2O8/H2O2 coreactants system, benefiting from the efficient peroxidase-like activity of the PtCo/CdS@GO toward H2O2, massive of transient reactive intermediates could react with K2S2O8, thus obtaining higher ECL emission. Therefore, the developed ECL immunosensor for anti-MPO detection displayed good analytical performance with good concentration linearity in the range of 0.02 to 1000 pg/mL and low detection limit down to 7.39 fg/mL. Conclusions The introduction of multi-function PtCo/CdS@GO luminophores into the established ECL immunoassay not only was successfully applied for specific detection of anti-MPO in clinical serum samples, but also provided a completely new concept to design other high-performance luminophores. Meaningfully, the ECL immunoassay strategy held wide potential for biomarkers detection in clinical diagnosis. Graphic abstract


2016 ◽  
Vol 7 (4) ◽  
pp. 2572-2578 ◽  
Author(s):  
Jin Xu ◽  
Shanyong Zhou ◽  
Datao Tu ◽  
Wei Zheng ◽  
Ping Huang ◽  
...  

We demonstrate the successful use of sub-5 nm Lu6O5F8:Eu3+nano-bioprobes for the ultrasensitive detection of prostate specific antigen in patient serum samples with a limit of detection of 0.52 pg mL−1.


2019 ◽  
Vol 166 (9) ◽  
pp. B3051-B3055 ◽  
Author(s):  
Raluca-Ioana Stefan-van Staden ◽  
Ioana Popa-Tudor

2019 ◽  
Author(s):  
Yongya Li ◽  
Hayam Mansour ◽  
Yanan Tang ◽  
Feng Li

AbstractHerein, we describe a proximity CRISPR Cas12a assay that harnesses “collateral” single-stranded DNase activity of Cas12a as a universal amplifier for the ultrasensitive detection of nucleic acids and proteins. The target recognition is achieved through proximity binding rather than recognition by CRISPR RNA (crRNA), which allows the flexible assay design and expansion to proteins. A binding-induced primer extension reaction is then used to generate a predesigned CRISPR-targetable sequence as a barcode for signal amplification. We demonstrate that our assay is highly sensitive and universal. As low as 1 fM nucleic acid target could be detected isothermally in a homogeneous solution via the integration with nicking cleavage. We’ve also successfully adapted the assay for the sensitive and wash-free detection of antibodies in both buffer and diluted human serum samples.


1989 ◽  
Vol 61 (01) ◽  
pp. 081-085 ◽  
Author(s):  
Simon Panzer ◽  
Christoph Stain ◽  
Hubert Hartl ◽  
Robert Dudczak ◽  
Klaus Lechner

SummaryLevels of anticardiolipin antibodies (ACA) were measured in 55 patients with haemophilia A in serum samples obtained in 1983 and in 1987. Twenty-one patients were negative for anti HIV-1 antibodies in 1983 and remained negative in 1987; 34 patients had anti HIV-1 antibodies in 1983; 17 of these latter patients remained asymptomatic, whereas 17 patients developed ARC or AIDS during the 4 years follow-up. Thirteen anti HIV-1 negative patients had elevated ACA levels in 1983; subsequently, a significant decrease was observed in all these subjects (p <0.001). All anti HIV-1 positive patients had elevated ACA levels in 1983; normal values were found in 9 patients in 1987. Yet, these changes were not significant (p >0.05). ACA levels were significantly higher in HIV-1 infected patients than in those without anti HIV-1 antibodies (p <0.05). There was no difference of ACA levels between the two anti HIV-1 positive patient groups, be it in 1983 or be it in 1987 (p >0.05). There was no correlation of ACA levels with serum IgG concentrations, CD4+ lymphocytes, or the consumption of factor VIII concentrates.


1996 ◽  
Vol 76 (06) ◽  
pp. 0925-0931 ◽  
Author(s):  
John F Carroll ◽  
Keith A Moskowitz ◽  
Niloo M Edwards ◽  
Thomas J Hickey ◽  
Eric A Rose ◽  
...  

SummaryTwenty-one cardiothoracic surgical patients have been treated with fibrin as a topical hemostatic/sealing agent, prepared from bovine fibrinogen clotted with bovine thrombin. Serum samples have been collected before treatment with fibrin and postoperatively between 1 and 9 days, 3 and 12 weeks, and 6 and 8 months. The titers of anti-bovine fibrinogen antibodies, measured by ELISA specific for immunoglobulins IgG or IgM, increased to maximal values after about 8 or 6 weeks, respectively. After 8 months, IgG titers were on average 20-fold lower than the mean maximal value, while IgM titers returned to the normal range. IgG was the predominant anti-bovine fibrinogen immunoglobulin as documented by ELISA, affinity chromatography and electrophoresis. Anti-bovine fibrinogen antibodies present in patients reacted readily with bovine fibrinogen, but did not cross-react with human fibrinogen as measured by ELISA or by immunoelectrophoresis. A significant amount of antibodies against bovine thrombin and factor V has been found, many cross-reacting with the human counterparts. No hemorrhagic or thrombotic complications, or clinically significant allergic reactions, occurred in any patient, in spite of antibody presence against some bovine and human coagulation factors. The treatment of patients with bovine fibrin, without induction of immunologic response against human fibrinogen, appeared to be an effective topical hemostatic/sealing measure.


1992 ◽  
Vol 67 (05) ◽  
pp. 507-509 ◽  
Author(s):  
John Gibson ◽  
Margaret Nelson ◽  
Ross Brown ◽  
Hatem Salem ◽  
Harry Kronenberg

SummaryIn order to investigate the possibility that autoantibodies to thrombomodulin (TM) may exist in patients with the lupus anticoagulant (LA) and perhaps be implicated in the pathogenesis of recurrent thrombosis seen in such patients, we developed an enzyme-immunoassay to screen serum samples for anti-human TM activity. The major technical problem encountered in developing this assay was to reduce the non-specific binding of serum components from both the LA positive and the negative population. Considerable reduction of non-specific binding was achieved by use of a phosphate/citrate buffer at pH 8.0 and the use of an optimal sample dilution of 1/40. In addition, samples were always tested in parallel in blank wells and results are expressed as an OD ratio. Samples from 113 patients with the LA were assayed and compared to 78 patients referred for LA testing but found to be negative. The mean OD values for the LA positive patients (± SD) was 1.36 (0.44) with a range of 0.78-2.57. This was virtually identical to the values for the LA negative population (1.38 ± 0.40, range 0.76-2.77). The results of this study indicate that there is no evidence for the presence of a significant autoantibody activity to TM in patients with the LA when compared to LA negative patients. If such autoantibodies do exist their frequency must be quite low.


Sign in / Sign up

Export Citation Format

Share Document