scholarly journals Multi-function PtCo nanozymes/CdS nanocrystals@graphene oxide luminophores and K2S2O8/H2O2 coreactants-based dual amplified electrochemiluminescence immunosensor for ultrasensitive detection of anti-myeloperoxidase antibody

2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Wei Yang ◽  
Zheng Zhou ◽  
Haiping Wu ◽  
Changjin Liu ◽  
Bo Shen ◽  
...  

Abstract Background Anti-myeloperoxidase antibody (anti-MPO) is an important biomarker for anti-neutrophil cytoplasm antibody (ANCA)-associated vasculitides (AAVs). However, the complicated operation procedures and insufficient sensitivity of conventional anti-MPO detection methods limit their application in monitoring efficacy of AAVs in clinical diagnosis. Herein, a dual amplified electrochemiluminescence (ECL) immunosensor based on multi-function PtCo nanozymes/CdS nanocrystals@graphene oxide (PtCo/CdS@GO) luminophores and K2S2O8/H2O2 coreactants has been fabricated for ultrasensitive detection of anti-MPO. Results PtCo/CdS@GO luminophores as novel signal amplification labels and nanocarriers to load rabbit anti-mouse IgG were synthesized by co-doping with Pt and Co nanozymes simultaneously with several considerable advantages, including astonishing peroxidase-like catalytic activity, high-efficiency luminescence performance and superior stability in aqueous solutions. Meanwhile, upon the K2S2O8/H2O2 coreactants system, benefiting from the efficient peroxidase-like activity of the PtCo/CdS@GO toward H2O2, massive of transient reactive intermediates could react with K2S2O8, thus obtaining higher ECL emission. Therefore, the developed ECL immunosensor for anti-MPO detection displayed good analytical performance with good concentration linearity in the range of 0.02 to 1000 pg/mL and low detection limit down to 7.39 fg/mL. Conclusions The introduction of multi-function PtCo/CdS@GO luminophores into the established ECL immunoassay not only was successfully applied for specific detection of anti-MPO in clinical serum samples, but also provided a completely new concept to design other high-performance luminophores. Meaningfully, the ECL immunoassay strategy held wide potential for biomarkers detection in clinical diagnosis. Graphic abstract

Crystals ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 1092
Author(s):  
Yudan Gou ◽  
Jun Wang ◽  
Yang Cheng ◽  
Yintao Guo ◽  
Xiao Xiao ◽  
...  

The development of high-performance tunnel junctions is critical for achieving high efficiency in multi-junction solar cells (MJSC) that can operate at high concentrations. We investigate silicon and tellurium co-doping of InGaAs quantum well inserts in p++-GaAs/n++-GaAs tunnel junctions and report a peak current density as high as 5839 A cm−2 with a series resistance of 5.86 × 10−5 Ω cm2. In addition, we discuss how device performance is affected by the growth temperature, thickness, and V/III ratio in the InGaAs layer. A simulation model indicates that the contribution of trap-assisted tunneling enhances carrier tunneling.


2020 ◽  
Vol 8 (5) ◽  
pp. 2701-2711 ◽  
Author(s):  
Sen Meng ◽  
Xing Zhao ◽  
Chun-Yan Tang ◽  
Peng Yu ◽  
Rui-Ying Bao ◽  
...  

A bridge-arched integrated evaporator that introduces air as the thermal insulation layer exhibits high-efficiency solar steam generation.


2021 ◽  
Author(s):  
Xiaoqiang Du ◽  
Guangyu Ma ◽  
Xiaoshuang Zhang

The development of high-performance and cost-effective bifunctional water splitting catalysts are of enormous significance to the hydrogen production industry from water electrolysis. Herein, an in-situ Co and N co-doping method...


Molecules ◽  
2021 ◽  
Vol 26 (14) ◽  
pp. 4141
Author(s):  
Marcin Gackowski ◽  
Anna Przybylska ◽  
Stefan Kruszewski ◽  
Marcin Koba ◽  
Katarzyna Mądra-Gackowska ◽  
...  

The present review summarizes scientific reports from between 2010 and 2019 on the use of capillary electrophoresis to quantify active constituents (i.e., phenolic compounds, coumarins, protoberberines, curcuminoids, iridoid glycosides, alkaloids, triterpene acids) in medicinal plants and herbal formulations. The present literature review is founded on PRISMA guidelines and selection criteria were formulated on the basis of PICOS (Population, Intervention, Comparison, Outcome, Study type). The scrutiny reveals capillary electrophoresis with ultraviolet detection as the most frequently used capillary electromigration technique for the selective separation and quantification of bioactive compounds. For the purpose of improvement of resolution and sensitivity, other detection methods are used (including mass spectrometry), modifiers to the background electrolyte are introduced and different extraction as well as pre-concentration techniques are employed. In conclusion, capillary electrophoresis is a powerful tool and for given applications it is comparable to high performance liquid chromatography. Short time of execution, high efficiency, versatility in separation modes and low consumption of solvents and sample make capillary electrophoresis an attractive and eco-friendly alternative to more expensive methods for the quality control of drugs or raw plant material without any relevant decrease in sensitivity.


Author(s):  
Vinod Kumar ◽  
Bhupen Songra ◽  
Richa Jain ◽  
Deeksha Mehta

Background: the present study was under taken to determine the role of CA-125 in the diagnosis of acute appendicitis (AA), to prevent its complications and also in preventing negative appendicectomies in tertiary care hospital. Methods: The study was conducted at a tertiary care and research center between 01/03/2018 to 30/06/2019. Patients admitted to the surgery department with diagnosis of AA were considered for the study. After informed consent, a, standardized history was obtained as a case Performa. Serum samples from all the cases with clinical diagnosis of AA were obtained and stored. Only the cases with histopathologically approved AA were included in the study. Cases operated for clinical diagnosis of AA, but not histopathologically proven AA was not included in the study. CA125 levels in cases with definitive diagnosis of AA were measured. Results: In present study, ROC curve analysis revealed the sensitivity of 87.27 % and specificity of 90.91 % when the CA 125 cut-off value of > 16.8 was taken to diagnose acute appendicitis. AUC was 0.911 with a standard error of 0.0292. Conclusion: In this study we have observed that CA125 showed a positive correlation with acute appendicitis, that was statistically not significant (P>0.05). We didn’t evaluate the correlation with the disease severity. We consider that CA125 can be used as a marker in acute appendicitis cases although further research is still needed. Keywords: CA125, Acute Appendicitis, Surgery.


2016 ◽  
Vol 11 (9) ◽  
pp. 764
Author(s):  
Lella Aicha Ayadi ◽  
Nihel Neji ◽  
Hassen Loukil ◽  
Mouhamed Ali Ben Ayed ◽  
Nouri Masmoudi

2018 ◽  
Vol 69 (3) ◽  
pp. 627-631 ◽  
Author(s):  
Viorica Ohriac (Popa) ◽  
Diana Cimpoesu ◽  
Adrian Florin Spac ◽  
Paul Nedelea ◽  
Voichita Lazureanu ◽  
...  

Pain is defined as a disagreeable sensory and emotional experience related to a tissue or potential lesion. Paracetamol (Acetaminophen) is the most used non-morphine analgesic. For the determination of paracetamol we developed and validated the high performance liquid chromatography (HPLC) analysis using a Dionex Ultimate 3000 liquid chromatograph equipped with a multidimensional detector. After determining the optimum conditions of analysis (80/20 water / acetonitrile mobile phase, flow rate 1.0 mL / min, detection wavelength 245 nm) we validated the method following the following parameters: linearity of response function, linearity of results, limit (LD = 0.66 mg / mL) and quantification limit (LQ = 2.00 mg / mL), and precision. The method of determining paracetamol by HPLC was applied to 30 samples of serum collected from patients who had pain and were treated with paracetamol.


Biomolecules ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 1083
Author(s):  
Aleksandra Filimoniuk ◽  
Agnieszka Blachnio-Zabielska ◽  
Monika Imierska ◽  
Dariusz Marek Lebensztejn ◽  
Urszula Daniluk

An altered ceramide composition in patients with inflammatory bowel disease (IBD) has been reported recently. The aim of this study was to evaluate the concentrations of sphingolipids in the serum of treatment-naive children with newly diagnosed IBD and to determine the diagnostic value of the tested lipids in pediatric IBD. The concentrations of sphingolipids in serum samples were evaluated using a quantitative method, an ultra-high-performance liquid chromatography-tandem mass spectrometry in children with Crohn’s disease (CD) (n=34), ulcerative colitis (UC) (n = 39), and controls (Ctr) (n = 24). Among the study groups, the most significant differences in concentrations were noted for C16:0-LacCer, especially in children with CD compared to Ctr or even to UC. Additionally, the relevant increase in C20:0-Cer and C18:1-Cer concentrations were detected in both IBD groups compared to Ctr. The enhanced C24:0-Cer level was observed only in UC, while C18:0-Cer only in the CD group. The highest area under the curve (AUC), specificity, and sensitivity were determined for C16:0-LacCer in CD diagnosis. Our results suggest that the serum LacC16-Cer may be a potential biomarker that distinguishes children with IBD from healthy controls and differentiates IBD subtypes. In addition, C20:0-Cer and C18:0-Cer levels also seem to be closely connected with IBD.


Sign in / Sign up

Export Citation Format

Share Document