Conformational effect on fluorescence emission of tetraphenylethylene-based metallacycles

Author(s):  
Zhewen Guo ◽  
Jun Zhao ◽  
Yuhang Liu ◽  
Guangfeng Li ◽  
Heng Wang ◽  
...  
2017 ◽  
Author(s):  
Pedro M. R. Paulo ◽  
David Botequim ◽  
Agnieszka Jóskowiak ◽  
Sofia Martins ◽  
Duarte M. F. Prazeres ◽  
...  

<div> <div> <div> <p>We have employed DNA-directed assembly to prepare dimers of gold nanoparticles and used their longitudinally coupled plasmon mode to enhance the fluorescence emission of an organic red-emitting dye, Atto-655. The plasmon- enhanced fluorescence of this dye using dimers of 80 nm particles was measured at single molecule detection level. The top enhancement factors were above 1000-fold in 71% of the dimers within a total of 32 dimers measured, and, in some cases, they reached almost 4000-fold, in good agreement with model simulations. Additionally, fluorescence lifetime correlation analysis enabled the separation of enhanced from non-enhanced emission simultaneously collected in our confocal detection volume. This approach allowed us to recover a short relaxation component exclusive to enhanced emission that is attributed to the interaction of the dye with DNA in the interparticle gaps. </p> </div> </div> </div>


2020 ◽  
Vol 17 (6) ◽  
pp. 472-478
Author(s):  
Wei-tao Gong ◽  
Wei-dong Qu ◽  
Guiling Ning

Two pyridinium amide-based receptors L1 and L2 with a small difference of H-bond position of the amide have been synthesized and characterized. Interestingly, they exhibited a huge difference in sensing towards AcO- and H2PO4 -, respectively. Receptor L1 was found to be ‘naked-eye’ selective for AcO- anions, while receptor L2 showed clear fluorescence enhancement selective to H2PO4 - anion. The recognition ability has been established by fluorescence emission, UV-vis spectra, and 1HNMR titration.


1982 ◽  
Vol 37 (3-4) ◽  
pp. 256-259 ◽  
Author(s):  
F. Schuler ◽  
P. Brandt ◽  
W. Wießner

Abstract An improved method for isolation of (photosystem II)-particles from Euglena gracilis, strain Z was established. PS II-particles isolated by ultrasonic treatment and following differential centrifugation show fluorescence emission and absorption spectra identical with in vivo properties of Euglena gracilis. These PS II-particles have only PS II-activity and contain CP a, the typical chlorophyll-protein-complex of PS II. No contamination of PS I-components are detectable.


2020 ◽  
Vol 74 (4) ◽  
pp. 439-451
Author(s):  
Philipp Holz ◽  
Christoph Pönisch ◽  
Albrecht Brandenburg

Imaging fluorescence spectroscopy proves to be a fast and sensitive method for measuring the thickness of thin coatings in the manufacturing industry. This encouraged us to systematically study, theoretically and experimentally, parameters that influence the fluorescence of thin layers. We analyzed the fluorescence signal as a function of the scattering and reflectance properties of the sample substrate. In addition, we investigated effects of the layer properties on fluorescence emission. A ray-tracing software is used to describe the influence of these parameters on the fluorescence emission of thin layers. Experiments using a custom-made system for imaging fluorescence analysis verify the simulations. This work shows a factor five variation of fluorescence intensity as a function of the reflectance of the sample substrate. Simulations show variations by a factor of up to eight for samples with different surface roughness. Results on tilted samples indicate a significant increase of the detected fluorescence signal, for fluorescent droplets on reflective substrates, if illuminated and coaxially observed at angles greater than 25°. These findings are of utmost relevance for all applications which utilize the fluorescence emission to quantify thin layers. These applications range from in-line lubricant monitoring in press plants to monitoring of functional coatings in medical technology and the detection of filmic contaminations.


2012 ◽  
Vol 14 (8) ◽  
Author(s):  
Ning Sui ◽  
Virginie Monnier ◽  
Yuriy Zakharko ◽  
Yann Chevolot ◽  
Sergei Alekseev ◽  
...  

2021 ◽  
Author(s):  
Xinxian Ma ◽  
Jinlong Yue ◽  
Bo Qiao ◽  
LIli Zhou ◽  
Yang Gao ◽  
...  

Supramolecular fluorescent materials have attracted considerable attention in recent years since they endow specific and unique properties to materials. Nevertheless, the utilization of photo-responsive characteristics to modulate their fluorescence emission...


RSC Advances ◽  
2020 ◽  
Vol 10 (71) ◽  
pp. 43459-43471
Author(s):  
Hussain A. Z. Sabek ◽  
Ahmed M. M. Alazaly ◽  
Dina Salah ◽  
Hesham S. Abdel-Samad ◽  
Mohamed A. Ismail ◽  
...  

Solvation-dependent photophysical properties of two push–pull thiophene-based compounds with donor–π–acceptor (D–π–A) structures were investigated using absorption, fluorescence emission and time resolved spectroscopy, and supported by different solvation models.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2797
Author(s):  
Jing-Jhong Gao ◽  
Ching-Wei Chiu ◽  
Kuo-Hsing Wen ◽  
Cheng-Sheng Huang

This paper presents a compact spectral detection system for common fluorescent and colorimetric assays. This system includes a gradient grating period guided-mode resonance (GGP-GMR) filter and charge-coupled device. In its current form, the GGP-GMR filter, which has a size of less than 2.5 mm, can achieve a spectral detection range of 500–700 nm. Through the direct measurement of the fluorescence emission, the proposed system was demonstrated to detect both the peak wavelength and its corresponding intensity. One fluorescent assay (albumin) and two colorimetric assays (albumin and creatinine) were performed to demonstrate the practical application of the proposed system for quantifying common liquid assays. The results of our system exhibited suitable agreement with those of a commercial spectrometer in terms of the assay sensitivity and limit of detection (LOD). With the proposed system, the fluorescent albumin, colorimetric albumin, and colorimetric creatinine assays achieved LODs of 40.99 and 398 and 25.49 mg/L, respectively. For a wide selection of biomolecules in point-of-care applications, the spectral detection range achieved by the GGP-GMR filter can be further extended and the simple and compact optical path configuration can be integrated with a lab-on-a-chip system.


AMB Express ◽  
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Susanna Gevorgyan ◽  
Robin Schubert ◽  
Mkrtich Yeranosyan ◽  
Lilit Gabrielyan ◽  
Armen Trchounian ◽  
...  

AbstractThe application of green synthesis in nanotechnology is growing day by day. It’s a safe and eco-friendly alternative to conventional methods. The current research aimed to study raw royal jelly’s potential in the green synthesis of silver nanoparticles and their antibacterial activity. Royal jelly served as a reducing and oxidizing agent in the green synthesis technology of colloidal silver nanoparticles. The UV–Vis maximum absorption at ~ 430 nm and fluorescence emission peaks at ~ 487 nm confirmed the presence of Ag NPs. Morphology and structural properties of Ag NPs and the effect of ultrasound studies revealed: (i) the formation of polydispersed and spherical particles with different sizes; (ii) size reduction and homogeneity increase by ultrasound treatment. Antibacterial activity of different concentrations of green synthesized Ag NPs has been assessed on Gram-negative S. typhimurium and Gram-positive S. aureus, revealing higher sensitivity on Gram-negative bacteria.


Sign in / Sign up

Export Citation Format

Share Document