Flexible multifunctional graphite nanosheet/electrospun-polyamide 66 nanocomposite sensor for ECG, strain, temperature and gas measurements

2020 ◽  
Vol 400 ◽  
pp. 125928 ◽  
Author(s):  
Lijun Lu ◽  
Bin Yang ◽  
Jingquan Liu
1975 ◽  
Vol 72 ◽  
pp. 735-740 ◽  
Author(s):  
Jean René Bernard ◽  
Can Hoang-Van ◽  
Stanislas Jean Teichner
Keyword(s):  

1976 ◽  
Vol 73 ◽  
pp. 799-802 ◽  
Author(s):  
Jean-René Bernard ◽  
Can Hoang-Van ◽  
Stanislas Jean Teichner
Keyword(s):  

Author(s):  
Ang Li ◽  
Jian Li ◽  
Zhengye Zhang ◽  
Zecheng Li ◽  
Hui Chi ◽  
...  

A dual-peptide controlled released system based on nHA/PA66 scaffold for enhancing bone regeneration.


Atmosphere ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 73
Author(s):  
Mae Sexauer Gustin ◽  
Sarrah M. Dunham-Cheatham ◽  
Jiaoyan Huang ◽  
Steve Lindberg ◽  
Seth N. Lyman

This review focuses on providing the history of measurement efforts to quantify and characterize the compounds of reactive mercury (RM), and the current status of measurement methods and knowledge. RM collectively represents gaseous oxidized mercury (GOM) and that bound to particles. The presence of RM was first recognized through measurement of coal-fired power plant emissions. Once discovered, researchers focused on developing methods for measuring RM in ambient air. First, tubular KCl-coated denuders were used for stack gas measurements, followed by mist chambers and annular denuders for ambient air measurements. For ~15 years, thermal desorption of an annular KCl denuder in the Tekran® speciation system was thought to be the gold standard for ambient GOM measurements. Research over the past ~10 years has shown that the KCl denuder does not collect GOM compounds with equal efficiency, and there are interferences with collection. Using a membrane-based system and an automated system—the Detector for Oxidized mercury System (DOHGS)—concentrations measured with the KCl denuder in the Tekran speciation system underestimate GOM concentrations by 1.3 to 13 times. Using nylon membranes it has been demonstrated that GOM/RM chemistry varies across space and time, and that this depends on the oxidant chemistry of the air. Future work should focus on development of better surfaces for collecting GOM/RM compounds, analytical methods to characterize GOM/RM chemistry, and high-resolution, calibrated measurement systems.


2021 ◽  
Vol 36 (3) ◽  
pp. 276-286
Author(s):  
Z. Dekel ◽  
S. Kenig

Abstract The mechanical, electrical, thermal, and rheological properties of micro injection molded nanocomposites comprising 2% and 5% carbon nanotubes (CNTs) incorporated in polycarbonate (PC), and polyamide 66 (PA) were studied. The design of experiments method was used to investigate the composition-process – properties relationship. Results indicated that the process variables significantly affected the flow patterns and resulting morphology during the filling stage of the microinjection molding (lIM) process, using 0.45 mm diameter lIM samples. Two distinct flow regimes have been identified in lIM using the low cross-section samples. The first was a conventional “fountain flow,” which resulted in a skin/core structure and reduced volume resistivity up to 10 X cm in the case of 5% CNTs and up to 100 X cm in 2% CNTs, in both polymers, respectively. In addition, inferior mechanical properties were obtained, attributed to polymer degradation under high shear rate conditions, when practicing high injection speeds, high mold temperatures, and high screw rotation velocities. The second was a “plug flow” due to wall slippage, obtained under low injection speeds, low mold temperatures, and low rotation velocities, leading to a substantial increase in modulus of elasticity (60%) with increased electrical resistivity up to 103 X cm for 5% CNTs and 105 X cm for 2% CNTs, respectively. The rheological percolation threshold was obtained at 2% CNTs while the electrical threshold was attained at 0.4% CNTs, in both polymers. It was concluded that in lIM, the process conditions should be closely monitored. In the case of high viscous heating, degradation of mechanical properties was obtained, while skin- core morphology formation enhanced electrical conductivity.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Joseph R. Roscioli ◽  
Laura K. Meredith ◽  
Joanne H. Shorter ◽  
Juliana Gil-Loaiza ◽  
Till H. M. Volkmann

AbstractSoil microbes vigorously produce and consume gases that reflect active soil biogeochemical processes. Soil gas measurements are therefore a powerful tool to monitor microbial activity. Yet, the majority of soil gases lack non-disruptive subsurface measurement methods at spatiotemporal scales relevant to microbial processes and soil structure. To address this need, we developed a soil gas sampling system that uses novel diffusive soil probes and sample transfer approaches for high-resolution sampling from discrete subsurface regions. Probe sampling requires transferring soil gas samples to above-ground gas analyzers where concentrations and isotopologues are measured. Obtaining representative soil gas samples has historically required balancing disruption to soil gas composition with measurement frequency and analyzer volume demand. These considerations have limited attempts to quantify trace gas spatial concentration gradients and heterogeneity at scales relevant to the soil microbiome. Here, we describe our new flexible diffusive probe sampling system integrated with a modified, reduced volume trace gas analyzer and demonstrate its application for subsurface monitoring of biogeochemical cycling of nitrous oxide (N2O) and its site-specific isotopologues, methane, carbon dioxide, and nitric oxide in controlled soil columns. The sampling system observed reproducible responses of soil gas concentrations to manipulations of soil nutrients and redox state, providing a new window into the microbial response to these key environmental forcings. Using site-specific N2O isotopologues as indicators of microbial processes, we constrain the dynamics of in situ microbial activity. Unlocking trace gas messengers of microbial activity will complement -omics approaches, challenge subsurface models, and improve understanding of soil heterogeneity to disentangle interactive processes in the subsurface biome.


2012 ◽  
Vol 5 (8) ◽  
pp. 547-550 ◽  
Author(s):  
Tim DeVries ◽  
Curtis Deutsch ◽  
François Primeau ◽  
Bonnie Chang ◽  
Allan Devol

Sign in / Sign up

Export Citation Format

Share Document