Three-Dimensional Photonic Nitrocellulose for Minimally Invasive Detection of Biomarker in Tumor Interstitial Fluid

2021 ◽  
pp. 134234
Author(s):  
Xing Dong ◽  
Biao Ma ◽  
Lanjie Lei ◽  
Yichen Chen ◽  
Chengtao Xu ◽  
...  
Author(s):  
Brett G. Darrow ◽  
Kyle A. Snowdon ◽  
Adrien Hespel

Abstract Objective The aim of this study was to evaluate the accuracy of patient-specific three-dimensional printed drill guides (3D-PDG) for the placement of a coxofemoral toggle via a minimally invasive approach. Materials and Methods Pre-procedure computed tomography (CT) data of 19 canine cadaveric hips were used to design a cadaver-specific 3D-PDG that conformed to the proximal femur. Femoral and acetabular bone tunnels were drilled through the 3D-PDG, and a coxofemoral toggle pin was placed. The accuracy of tunnel placement was evaluated with post-procedure CT and gross dissection. Results Coxofemoral toggle pins were successfully placed in all dogs. Mean exit point translation at the fovea capitis was 2.5 mm (0.2–7.5) when comparing pre- and post-procedure CT scans. Gross dissection revealed the bone tunnel exited the fovea capitis inside (3/19), partially inside (12/19) and outside of (4/19) the ligament of the head of the femur. Placement of the bone tunnel through the acetabulum was inside (16/19), partially inside (1/19) and outside (2/19) of the acetabular fossa. Small 1 to 2 mm articular cartilage fragments were noted in 10 of 19 specimens. Clinical Significance Three-dimensional printed drill guide designed for coxofemoral toggle pin application is feasible. Errors are attributed to surgical execution and identification of the borders of the fovea capitis on CT data. Future studies should investigate modifications to 3D-PDG design and methods. Three-dimensional printed drill guide for coxofemoral toggle pin placement warrants consideration for use in select clinical cases of traumatic coxofemoral luxation.


2007 ◽  
Vol 60 (suppl_2) ◽  
pp. ONS-129-ONS-139 ◽  
Author(s):  
Daisuke Togawa ◽  
Mark M. Kayanja ◽  
Mary K. Reinhardt ◽  
Moshe Shoham ◽  
Alin Balter ◽  
...  

Abstract Objective: To evaluate the accuracy of a novel bone-mounted miniature robotic system for percutaneous placement of pedicle and translaminar facet screws. Methods: Thirty-five spinal levels in 10 cadavers were instrumented. Each cadaver's entire torso was scanned before the procedure. Surgeons planned optimal entry points and trajectories for screws on reconstructed three-dimensional virtual x-rays of each vertebra. Either a clamp or a minimally invasive external frame was attached to the bony anatomy. Anteroposterior and lateral fluoroscopic images using targeting devices were obtained and automatically registered with the virtual x-rays of each vertebra generated from the computed tomographic scan obtained before the procedure. A miniature robot was mounted onto the clamp and external frame and the system controlled the robot's motions to align the cannulated drill guide along the planned trajectory. A drill bit was introduced through the cannulated guide and a hole was drilled through the cortex. Then, K-wires were introduced and advanced through the same cannulated guide and left inside the cadaver. The cadavers were scanned with computed tomography after the procedure and the system's accuracy was evaluated in three planes, comparing K-wire positions with the preoperative plan. A total of fifty-five procedures were evaluated. Results: Twenty-nine of 32 K-wires and all four screws were placed with less than 1.5 mm of deviation; average deviation was 0.87 ± 0.63 mm (range, 0-1.7 mm) from the preoperative plan in this group. Sixteen of 19 K-wires were placed with less than 1.5 mm of deviation. There was one broken and one bent K-wire. Another K-wire was misplaced because of collision with the previously placed wire on the contralateral side of the same vertebra because of a mistake in planning, resulting in a 6.5-mm deviation. When this case was excluded, average deviation was 0.82 ± 0.65 mm (range, 0-1.5 mm). Conclusion: These results verify the system's accuracy and support its use for minimally invasive spine surgery in selected patients.


2014 ◽  
Vol 5 ◽  
pp. MEI.S13342
Author(s):  
Francesca Destro ◽  
Noemi Cantone ◽  
Mario Lima

Minimally invasive surgery (MIS) is a relatively new surgery comprising various procedures performed with special miniaturized instruments and imaging reproduction systems. Technological advances have made MIS an efficient, safe, and applicable tool for pediatric surgeons with unquestionable advantages. The recent introduction of three-dimensional (3D) high definition systems has been advocated in order to overcome some of the problems related to standard MIS visual limitations. This short paper recapitulates the necessity to minimize MIS visualization limitations and reports the characteristics of new laparoscopic 3D systems.


2016 ◽  
Vol 11 (2) ◽  
pp. 220-234 ◽  
Author(s):  
Ann Rita Halvorsen ◽  
Åslaug Helland ◽  
Pavel Gromov ◽  
Vera Timmermans Wielenga ◽  
Maj-Lis Møller Talman ◽  
...  

2021 ◽  
Vol 9 (Suppl 3) ◽  
pp. A691-A691
Author(s):  
Yupeng Wang ◽  
Chufan Cai ◽  
Dayana Rivadeneira ◽  
Alexander Muir ◽  
Greg Delgoffe

BackgroundWhile CD8 T cells are crucial for anti-tumor immunity, tumor infiltrating CD8 T cells encounter stressors which deviate their differentiation to a dysfunctional, exhausted phenotype. T cell functions are closely regulated by T cell metabolism, and the dysfunctional vasculature in tumor tissues and the deregulated metabolism of tumor cells lead to depletion of nutrients and accumulation of metabolic wastes in the tumor microenvironment (TME). Thus, the unbalanced levels of the nutrients and the metabolic wastes might skew the metabolism of T cells thus contributing to T cell dysfunction.MethodsOvalbumin-specific OT-I cells were activated with SIINFEKL/IL2 and cultured with IL2. The tumor interstitial fluid media (TIFM) was formulated based on the concentrations of the metabolites measured in the tumor interstitial fluid of pancreatic ductal adenocarcinoma.1 Purified arginine and phosphoethanolamine (PEtn) were used to change their levels in TIFM/RPMI1640 culture. Expression level of cytokines and PD-1 was measured by flow cytometry.ResultsWe sought to determine how T cells would differentiate, in vitro, if they were exposed only to the metabolites present in the TME. Using media formulated to model the metabolic composition of tumor interstitial fluid (TIFM),1 we show that CD8 T cells develop features of exhausted T cells in the TIFM culture: reduced proliferation, increased expression of PD-1 and decreased cytokine production. Using 'dropout' and 'add-back' approaches, we found arginine levels as a major contributor to the proliferation defect observed in TIFM-cultured T cells. Arginine was sufficient to restore proliferative capacity to T cells cultured in TIFM, but had no effect on the inhibited cytokine production. We then asked which metabolites were enriched in the TIFM, finding that PEtn, an intermediate in the ethanolamine branch of the Kennedy pathway and an oncometabolite enriched in the interstitial of many solid tumors, up-regulates PD-1 expression and compromises the cytokine production of the cells in culture. Depletion of Pcyt2, the metabolizing enzyme of PEtn and the rate limiting enzyme in the Kennedy pathway, makes CD8 T cells resistant to the effects of PEtn.ConclusionsOur data shows that the metabolic environment in the TME can be recapitulated in vitro and is sufficient to drive T cell dysfunction. Arginine depletion acts as a major inhibitor of T cell proliferation in the TME, but the oncometabolite PEtn drives a hypofunctional effector fate of T cells. Targeting PEtn metabolism via Pcyt2 depletion or inhibition is a potential target to reinvigorate T cells and enhance anti-tumor immunity.ReferenceSullivan MR, Danai LV, Lewis CA, Chan SH, Gui DY, Kunchok T, Dennstedt EA, Vander Heiden MG, Muir A. Quantification of microenvironmental metabolites in murine cancers reveals determinants of tumor nutrient availability. Elife 2019;;8:e44235. doi: 10.7554/eLife.44235. PMID: 30990168; PMCID: PMC6510537.


2018 ◽  
Author(s):  
Mark R. Sullivan ◽  
Laura V. Danai ◽  
Caroline A. Lewis ◽  
Sze Ham Chan ◽  
Dan Y. Gui ◽  
...  

AbstractCancer cell metabolism is heavily influenced by microenvironmental factors, including nutrient availability. Therefore, knowledge of microenvironmental nutrient levels is essential to understand tumor metabolism. To measure the extracellular nutrient levels available to tumors, we developed a quantitative metabolomics method to measure the absolute concentrations of >118 metabolites in plasma and tumor interstitial fluid, the extracellular fluid that perfuses tumors. Comparison of nutrient levels in tumor interstitial fluid and plasma revealed that the nutrients available to tumors differ from those present in circulation. Further, by comparing interstitial fluid nutrient levels between autochthonous and transplant models of murine pancreatic and lung adenocarcinoma, we found that tumor type, anatomical location and animal diet affect local nutrient availability. These data provide a comprehensive characterization of the nutrients present in the tumor microenvironment of widely used models of lung and pancreatic cancer and identify factors that influence metabolite levels in tumors.Impact StatementNutrient availability is an important tumor microenvironmental factor that impacts cancer cell biology; we developed methods to measure nutrients available to tumor cells and characterized factors that influence tumor nutrient availability.


Sign in / Sign up

Export Citation Format

Share Document