Contribution of extracellular polymeric substances and microbial community on the safety of drinking water quality: By mean of Cu/activated carbon biofiltration

Chemosphere ◽  
2021 ◽  
pp. 131686
Author(s):  
Zhihao Bi ◽  
Tong Li ◽  
Xueci Xing ◽  
Peng Qi ◽  
Zesong Li ◽  
...  
2018 ◽  
Vol 51 (17) ◽  
pp. 752-757 ◽  
Author(s):  
Jiang Sheng ◽  
Wang Weixing ◽  
Yu Jieping ◽  
Huang Zhongqiang

2021 ◽  
Author(s):  
Bayable Atanfu ◽  
Adey Desta ◽  
Fassil Assefa

Abstract BackgroundUnderstanding ecology of microbiomes in drinking water distribution systems is the most important notion in delivering safe drinking water. Despite cultivation-based methods routinelyemployed in monitoring drinking water quality, cultivation of specific indicator organisms alone is not always guarantee for assuring safe drinking water delivery. The presence of complex microbiomes in drinking water distribution systems affects treatment effectiveness leading to poor quality water which as a result affects health of human and animals. Drinking water treatment and distribution systems harbor various microbiota despite efforts made in improving water infrastructures and several waterborne diseases become serious problems in the water industry, specially, in developing Countries. Intermittent water supply, long-time of water storage, low water pressure in distribution systems, storage tankers and pipes as well as contaminated source water are among many of the factors responsible for low drinking water quality which in turn affecting health of people. The aim of this study was to explore microbial diversity and structure in water samples collected from source water, treated water, reservoirs, and several household points of use locations (taps). High throughput Illumina sequencing technology was employed by targeting V4 region of 16S rRNA following Illumina protocol to analyze the community structure of bacteria. ResultsThe core dominating taxa were Proteobacteria followed by Firmicutes, Bacteroidetes and Actinobacteria. Gamma proteobacteria were dominant among other Proteobacterial classes across all sampling points. Opportunistic bacterial genera such as Pseudomonas, Legionella, Klebsiella, Escherichia, Actinobacteria, as well as eukaryotic microbes like Cryptosporidium, Hartmanella, Acanthamoeba, Aspergillus, and Candida were also the abundant taxa found alongthe distribution systems. The shift in microbial community structure from source to point of uselocations were influenced by factors such as residual free chlorine, intermittent water supply andlong-time storage at the household. The shift in microbial community structure from source to point of use locations were influenced by factors such as residual free chlorine, intermittent water supply and long-time storage at the household.ConclusionsThe complex microbiota which was present in different sample sites receiving treated water from the two treatment plants (Legedadi and Gefersa) starting from source water to household point of consumption across the distribution systems in Addis Ababa brings drinking water quality problem which further causes significant health problems to both human and animal health. Treatment ineffectiveness, disinfection inefficiency, poor maintenance actions, leakage of sewage and other domestic wastes are few among many other factors responsible for degraded drinking water quality in this study putting health at high risk which, this, leads to morbidity and mortality. Findings of this research provide important and bassline information to understand the microbial profiles of drinking water along source water and distribution systems.


2011 ◽  
Vol 33 (6) ◽  
pp. 711-716 ◽  
Author(s):  
Flávia Vieira da Silva ◽  
Natália Ueda Yamaguchi ◽  
Gilselaine Afonso Lovato ◽  
Fernando Alves da Silva ◽  
Miria Hespanhol Miranda Reis ◽  
...  

2016 ◽  
Vol 15 (2) ◽  
pp. 435-442 ◽  
Author(s):  
Wendong Wang ◽  
Shan Song ◽  
Zixia Qiao ◽  
Qin Yang ◽  
Mengmeng Wang ◽  
...  

Author(s):  
Dora Cardona Rivas ◽  
Militza Yulain Cardona Guzmán ◽  
Olga Lucía Ocampo López

Objective: To characterize the burden of intestinal infectious diseases attributable to drinking-water quality in 27 municipalities in the central region of Colombia. Materials and methods: A time-trend ecological study. The drinking-water quality of the National Institute of Health and the Institute of Hydrology, Meteorology and Environmental Studies was identified. The disease burden was calculated based on the mortality registered in the National Department of Statistics and the records of morbidity attended by the Social Protection Integrated Information System. The etiological agents reported in morbidity records and the observation of environmental conditions in the municipalities of the study were included. The disease burden was determined according to the methodology recommended by the World Health Organization (WHO).


Author(s):  
Yu.A. Novikova ◽  
I.O. Myasnikov ◽  
A.A. Kovshov ◽  
N.A. Tikhonova ◽  
N.S. Bashketova

Summary. Introduction: Drinking water is one of the most important environmental factors sustaining life and determining human health. The goal of the Russian Federal Clean Water Project is to improve drinking water quality through upgrading of water treatment and supply systems using advanced technologies, including those developed by the military-industrial complex. The most informative and reliable sources of information for assessing drinking water quality are the results of systematic laboratory testing obtained within the framework of socio-hygienic monitoring (SGM) and production control carried out by water supply organizations. The objective of our study was to formulate approaches to organizing quality monitoring programs for centralized cold water supply systems. Materials and methods: We reviewed programs and results of drinking water quality laboratory tests performed by Rospotrebnadzor bodies and institutions within the framework of SGM in 2017–2018. Results: We established that drinking water quality monitoring in the constituent entities of the Russian Federation differs significantly in the number of monitoring points (566 in the Krasnoyarsk Krai vs 10 in Sevastopol) and measured indicators, especially sanitary and chemical ones (53 inorganic and organic substances in the Kemerovo Region vs one indicator in the Amur Region). Discussion: For a more complete and objective assessment of drinking water quality in centralized cold water supply systems, monitoring points should be organized at all stages of water supply with account for the coverage of the maximum number of people supplied with water from a particular network. Thus, the number of points in the distribution network should depend, inter alia, on the size of population served. In urban settlements with up to 10,000 inhabitants, for example, at least 4 points should be organized while in the cities with more than 3,000,000 inhabitants at least 80 points are necessary. We developed minimum mandatory lists of indicators and approaches to selecting priority indices to be monitored at all stages of drinking water supply.


1999 ◽  
Vol 39 (2) ◽  
pp. 201-208 ◽  
Author(s):  
C. Dierkes ◽  
W. F. Geiger

Runoff from highways contains significant loads of heavy metals and hydrocarbons. According to German regulations, it should be infiltrated over embankments to support groundwater-recharge. To investigate the decontaminating effect of greened embankments, soil-monoliths from highways with high traffic densities were taken. Soils were analyzed to characterize the contamination in relation to distance and depth for lead, zinc, copper, cadmium, PAH and MOTH. Lysimeters were charged in the field and laboratory with highway runoff to study the effluents under defined conditions. Concentrations of pollutants in roadside soils depend on the age of embankments and traffic density. Highest concentrations were found in the upper 5 cm of the soil and within a distance of up to two metres from the street. Concentrations of most pollutants decreased rapidly with depth and distance. Lead and cadmium could not be detected in lysimeter effluent. Zinc and copper were found in concentrations that did not exceed drinking water quality limits.