scholarly journals Gender-specific reference values for high-sensitivity cardiac troponin T and I in well-phenotyped healthy individuals and validity of high-sensitivity assay designation

2020 ◽  
Vol 78 ◽  
pp. 18-24 ◽  
Author(s):  
Evangelos Giannitsis ◽  
Matthias Mueller-Hennessen ◽  
Tanja Zeller ◽  
Anna Schuebler ◽  
Matthias Aurich ◽  
...  
2014 ◽  
Vol 60 (6) ◽  
pp. 838-847 ◽  
Author(s):  
Kristin M Aakre ◽  
Thomas Røraas ◽  
Per Hyltoft Petersen ◽  
Einar Svarstad ◽  
Hilde Sellevoll ◽  
...  

Abstract BACKGROUND Myocardial infarction (MI) is diagnosed by the finding of a single cardiac troponin value above the 99th percentile and a significant time-dependent change in cardiac troponin concentration. The aim of this study was to determine the 90-min and weekly biological variations, the reference change value (RCV), and the index of individuality (II) of high-sensitivity cardiac troponin T (hs-cTnT) (Roche Diagnostics) and hs-cTnI (Abbott Diagnostics) in patients receiving hemodialysis (HD) and in healthy individuals. METHOD Blood samples were collected from 19 HD patients (on an HD-free day) and 20 healthy individuals at 90-min intervals over a 6-h period (between 08:30 and 14:30) and before the midweek HD treatment for 10 weeks. The within-person variation (CVi), between-person variation, RCV, and II were calculated. RESULTS During the 6-h sampling period, the concentrations of hs-cTnT (both groups) and hs-cTnI (HD patients only) decreased on average by 0.8% to 1.7% per hour, respectively. These declining trends were included in the calculation of a 90-min asymmetric RCV: −8%/+5% in HD patients (hs-cTnT), −18%/+21% in HD patients (hs-cTnI), −27%/+29% in healthy individuals (hs-cTnT), and −39%/+64% in healthy individuals (hs-cTnI). The II was low in both groups for both assays. The weekly CVi values were approximately 8% (hs-cTnT) and 15% (hs-cTnI) in both groups. CONCLUSIONS When using a cardiac troponin change of 20%–50% to diagnose an MI, the false-positive rate is likely to be lower for the hs-cTnT assay than for the hs-cTnI assay. The low II suggests that use of a diagnostic cutoff value can be omitted.


Author(s):  
Chen Dongxu ◽  
Zhou Yannan ◽  
Yang Yilin ◽  
Yao Chenling ◽  
Gu Guorong ◽  
...  

Abstract Objectives A rapid 0 h/1 h algorithm using high-sensitivity cardiac troponin T (hs-cTnT) for rule-out and rule-in of non-ST-segment elevation myocardial infarction (NSTEMI) is recommended by the European Society of Cardiology. We aim to prospectively evaluate the diagnostic performance of the algorithm in Chinese Han patients with suspected NSTEMI. Methods In this prospective diagnostic cohort study, 577 patients presenting to the emergency department with suspected NSTEMI and recent (<12 h) onset of symptoms were enrolled. The levels of serum hs-cTnT were measured on admission, 1 h later and 4–14 h later. All patients underwent the initial clinical assessment and were triaged into three groups (rule-out, rule-in and observe) according to the 0 h/1 h algorithm. The major cardiovascular events (MACE) were evaluated at the 7-day and 30-day follow-ups. Results Among 577 enrolled patients, NSTEMI was the final diagnosis for 106 (18.4%) patients. Based on the hs-cTnT 0 h/1 h algorithm, 148 patients (25.6%) were classified as rule-out, 278 patients (48.2%) as rule-in and 151 patients (26.2%) were assigned to the observe group. The rule-out approach resulted in a sensitivity of 100% and negative predictive value of 100%. The rule-in approach resulted in a specificity of 62.9% [95% CI (58.5–67.2%)] and positive predictive value of 37.1% [95%CI (31.3–42.8%)]. No MACE was observed in the rule-out group within 30-day follow-up. Conclusions The hs-cTnT 0 h/1 h algorithm is a safe tool for early rule-out of NSTEMI, while probably not an effective strategy for accurate rule-in of NSTEMI in Chinese Han population.


Sign in / Sign up

Export Citation Format

Share Document