Diagnostic accuracy of clinically reported adenomyosis on pelvic ultrasound and MRI compared to surgical pathology

Author(s):  
Nicole C. Zanolli ◽  
Brendan C. Cline ◽  
Nicholas T. Befera ◽  
Jonathan G. Martin
2017 ◽  
Vol 51 (1) ◽  
pp. 23-29 ◽  
Author(s):  
Harun Arslan ◽  
Mehmet Fatih Özbay ◽  
İskan Çallı ◽  
Erkan Doğan ◽  
Sebahattin Çelik ◽  
...  

Abstract Background Diagnostic performance of Diffusion-Weighted magnetic resonance Imaging (DWI) and Multi-Detector Computed Tomography (MDCT) for TNM (Tumor, Lymph node, Metastasis) staging of gastric cancer was compared. Patients and methods We used axial T2-weighted images and DWI (b-0,400 and b-800 s/mm2) protocol on 51 pre-operative patients who had been diagnosed with gastric cancer. We also conducted MDCT examinations on them. We looked for a signal increase in the series of DWI images. The depth of tumor invasion in the stomach wall (tumor (T) staging), the involvement of lymph nodes (nodal (N) staging), and the presence or absence of metastases (metastatic staging) in DWI and CT images according to the TNM staging system were evaluated. In each diagnosis of the tumors, sensitivity, specificity, positive and negative accuracy rates of DWI and MDCT examinations were found through a comparison with the results of the surgical pathology, which is the gold standard method. In addition to the compatibilities of each examination with surgical pathology, kappa statistics were used. Results Sensitivity and specificity of DWI and MDCT in lymph node staging were as follows: N1: DWI: 75.0%, 84.6%; MDCT: 66.7%, 82%;N2: DWI: 79.3%, 77.3%; MDCT: 69.0%, 68.2%; N3: DWI: 60.0%, 97.6%; MDCT: 50.0%, 90.2%. The diagnostic tool DWI seemed more compatible with the gold standard method (surgical pathology), especially in the staging of lymph node, when compared to MDCT. On the other hand, in T staging, the results of DWI and MDCT were better than the gold standard when the T stage increased. However, DWI did not demonstrate superiority to MDCT. The sensitivity and specificity of both imaging techniques for detecting distant metastasis were 100%. Conclusions The diagnostic accuracy of DWI for TNM staging in gastric cancer before surgery is at a comparable level with MDCT and adding DWI to routine protocol of evaluating lymph nodes metastasis might increase diagnostic accuracy.


2021 ◽  
pp. 1-6
Author(s):  
Amalie C. Thavikulwat ◽  
Jim S. Wu ◽  
Xiaohe Chen ◽  
Megan E. Anderson ◽  
Ashley Ward ◽  
...  

Author(s):  
Ling-Yu Guo ◽  
Phyllis Schneider ◽  
William Harrison

Purpose This study provided reference data and examined psychometric properties for clausal density (CD; i.e., number of clauses per utterance) in children between ages 4 and 9 years from the database of the Edmonton Narrative Norms Instrument (ENNI). Method Participants in the ENNI database included 300 children with typical language (TL) and 77 children with language impairment (LI) between the ages of 4;0 (years;months) and 9;11. Narrative samples were collected using a story generation task, in which children were asked to tell stories based on six picture sequences. CD was computed from the narrative samples. The split-half reliability, concurrent criterion validity, and diagnostic accuracy were evaluated for CD by age. Results CD scores increased significantly between ages 4 and 9 years in children with TL and those with LI. Children with TL produced higher CD scores than those with LI at each age level. In addition, the correlation coefficients for the split-half reliability and concurrent criterion validity of CD scores were all significant at each age level, with the magnitude ranging from small to large. The diagnostic accuracy of CD scores, as revealed by sensitivity, specificity, and likelihood ratios, was poor. Conclusions The finding on diagnostic accuracy did not support the use of CD for identifying children with LI between ages 4 and 9 years. However, given the attested reliability and validity for CD, reference data of CD from the ENNI database can be used for evaluating children's difficulties with complex syntax and monitoring their change over time. Supplemental Material https://doi.org/10.23641/asha.13172129


2007 ◽  
Vol 177 (4S) ◽  
pp. 649-649
Author(s):  
Ponnambalam Chandrasekar ◽  
Jeremy Raynard ◽  
Abdul Sayed ◽  
Faiyaz Kapasi ◽  
Jaspal S. Virdi ◽  
...  

2019 ◽  
Vol 25 ◽  
pp. 19
Author(s):  
Ravinder Jeet Kaur ◽  
Shobana Athimulam ◽  
Molly Van Norman ◽  
Melinda Thomas ◽  
Stefan K. Grebe ◽  
...  

VASA ◽  
2016 ◽  
Vol 45 (2) ◽  
pp. 149-154 ◽  
Author(s):  
Jie Li ◽  
Lei Feng ◽  
Jiangbo Li ◽  
Jian Tang

Abstract. Background: The aim of this meta-analysis was to evaluate the diagnostic accuracy of magnetic resonance angiography (MRA) for acute pulmonary embolism (PE). Methods: A systematic literature search was conducted that included studies from January 2000 to August 2015 using the electronic databases PubMed, Embase and Springer link. The summary receiver operating characteristic (SROC) curve, sensitivity, specificity, positive likelihood ratios (PLR), negative likelihood ratios (NLR), and diagnostic odds ratio (DOR) as well as the 95 % confidence intervals (CIs) were calculated to evaluate the diagnostic accuracy of MRA for acute PE. Meta-disc software version 1.4 was used to analyze the data. Results: Five studies were included in this meta-analysis. The pooled sensitivity (86 %, 95 % CI: 81 % to 90 %) and specificity (99 %, 95 % CI: 98 % to 100 %) demonstrated that MRA diagnosis had limited sensitivity and high specificity in the detection of acute PE. The pooled estimate of PLR (41.64, 95 % CI: 17.97 to 96.48) and NLR (0.17, 95 % CI: 0.11 to 0.27) provided evidence for the low missed diagnosis and misdiagnosis rates of MRA for acute PE. The high diagnostic accuracy of MRA for acute PE was demonstrated by the overall DOR (456.51, 95 % CI: 178.38 - 1168.31) and SROC curves (AUC = 0.9902 ± 0.0061). Conclusions: MRA can be used for the diagnosis of acute PE. However, due to limited sensitivity, MRA cannot be used as a stand-alone test to exclude acute PE.


VASA ◽  
2019 ◽  
Vol 48 (6) ◽  
pp. 516-522 ◽  
Author(s):  
Verena Mayr ◽  
Mirko Hirschl ◽  
Peter Klein-Weigel ◽  
Luka Girardi ◽  
Michael Kundi

Summary. Background: For diagnosis of peripheral arterial occlusive disease (PAD), a Doppler-based ankle-brachial-index (dABI) is recommended as the first non-invasive measurement. Due to limitations of dABI, oscillometry might be used as an alternative. The aim of our study was to investigate whether a semi-automatic, four-point oscillometric device provides comparable diagnostic accuracy. Furthermore, time requirements and patient preferences were evaluated. Patients and methods: 286 patients were recruited for the study; 140 without and 146 with PAD. The Doppler-based (dABI) and oscillometric (oABI and pulse wave index – PWI) measurements were performed on the same day in a randomized cross-over design. Specificity and sensitivity against verified PAD diagnosis were computed and compared by McNemar tests. ROC analyses were performed and areas under the curve were compared by non-parametric methods. Results: oABI had significantly lower sensitivity (65.8%, 95% CI: 59.2%–71.9%) compared to dABI (87.3%, CI: 81.9–91.3%) but significantly higher specificity (79.7%, 74.7–83.9% vs. 67.0%, 61.3–72.2%). PWI had a comparable sensitivity to dABI. The combination of oABI and PWI had the highest sensitivity (88.8%, 85.7–91.4%). ROC analysis revealed that PWI had the largest area under the curve, but no significant differences between oABI and dABI were observed. Time requirement for oABI was significantly shorter by about 5 min and significantly more patients would prefer oABI for future testing. Conclusions: Semi-automatic oABI measurements using the AngER-device provide comparable diagnostic results to the conventional Doppler method while PWI performed best. The time saved by oscillometry could be important, especially in high volume centers and epidemiologic studies.


Sign in / Sign up

Export Citation Format

Share Document