Flame stabilization and local combustion modes in a cavity-based scramjet using different fuel injection schemes

2021 ◽  
Vol 233 ◽  
pp. 111562
Author(s):  
Donggang Cao ◽  
Haim Elya Brod ◽  
Neta Yokev ◽  
Dan Michaels
Author(s):  
Tommaso Bacci ◽  
Tommaso Lenzi ◽  
Alessio Picchi ◽  
Lorenzo Mazzei ◽  
Bruno Facchini

Modern lean burn aero-engine combustors make use of relevant swirl degrees for flame stabilization. Moreover, important temperature distortions are generated, in tangential and radial directions, due to discrete fuel injection and liner cooling flows respectively. At the same time, more efficient devices are employed for liner cooling and a less intense mixing with the mainstream occurs. As a result, aggressive swirl fields, high turbulence intensities, and strong hot streaks are achieved at the turbine inlet. In order to understand combustor-turbine flow field interactions, it is mandatory to collect reliable experimental data at representative flow conditions. While the separated effects of temperature, swirl, and turbulence on the first turbine stage have been widely investigated, reduced experimental data is available when it comes to consider all these factors together.In this perspective, an annular three-sector combustor simulator with fully cooled high pressure vanes has been designed and installed at the THT Lab of University of Florence. The test rig is equipped with three axial swirlers, effusion cooled liners, and six film cooled high pressure vanes passages, for a vortex-to-vane count ratio of 1:2. The relative clocking position between swirlers and vanes has been chosen in order to have the leading edge of the central NGV aligned with the central swirler. In order to generate representative conditions, a heated mainstream passes though the axial swirlers of the combustor simulator, while the effusion cooled liners are fed by air at ambient temperature. The resulting flow field exiting from the combustor simulator and approaching the cooled vane can be considered representative of a modern Lean Burn aero engine combustor with swirl angles above ±50 deg, turbulence intensities up to about 28% and maximum-to-minimum temperature ratio of about 1.25. With the final aim of investigating the hot streaks evolution through the cooled high pressure vane, the mean aerothermal field (temperature, pressure, and velocity fields) has been evaluated by means of a five-hole probe equipped with a thermocouple and traversed upstream and downstream of the NGV cascade.


Author(s):  
Abhishek Dubey ◽  
Pooja Nema ◽  
Abhijit Kushari

Abstract This paper describes experimental investigation of a Reverse Flow Slinger (RFS) combustor that has been developed in order to attain high flame stability and low emissions in gas turbine engines. The combustor employs centrifugal fuel injection through a rotary atomizer and performs flame stabilization at the stagnation zone generated by reverse flow configuration. The design facilitates entrainment of hot product gases and internal preheating of the inlet air which enhances flame stability and permits stable lean operation for low NOx. Moreover, the use of rotary atomizer eliminates the need for high injection pressure resulting in a compact and lightweight design. Atmospheric pressure combustion was performed with liquid fuels, Jet A-1 and Methanol at ultra-lean fuel air ratios (FAR) with thermal intensity of 28 - 50 MW/m3atm. Combustor performance was evaluated by analyzing the lean blowout, emissions and combustion efficiency. Test results showed high flame stability of combustor and a very low lean blowout corresponding to global equivalence ratio of around 0.1 was obtained. Sustained and stable combustion at low heat release was attained and NOx emissions as low as of 0.4 g/Kg and 0.1 g/Kg were obtained with Jet A-1 and Methanol respectively. Combustion efficiency of 55% and 90% was obtained in operation with Jet A-1 and Methanol. Performance of the combustor was significantly better with Methanol in terms of emissions and efficiency.


Author(s):  
Jens Fa¨rber ◽  
Rainer Koch ◽  
Hans-Jo¨rg Bauer ◽  
Matthias Hase ◽  
Werner Krebs

The flame structure and the limits of operation of a lean premixed swirl flame were experimentally investigated under piloted and non-piloted conditions. Flame stabilization and blow out limits are discussed with respect to pilot fuel injection and combustor liner cooling for lean operating conditions. Two distinctly different flow patterns are found to develop depending on piloting and liner cooling parameters. These flow patterns are characterized with respect to flame stability, blow out limits, combustion noise and emissions. The combustion system explored consists of a single burner similar to the burners used in Siemens annular combustion systems. The burner feeds a distinctively non-adiabatic combustion chamber operated with natural gas under atmospheric pressure. Liner cooling is mimicked by purely convective cooling and an additional flow of ‘leakage air’ injected into the combustion chamber. Both, this additional air flow and the pilot fuel ratio were found to have a strong influence on the flow structure and stability of the flame close to the lean blow off limit (LBO). It is shown by Laser Doppler Velocimetry (LDV) that the angle of the swirl cone is strongly affected by pilot fuel injection. Two distinct types of flow patterns are observed close to LBO in this large scale setup: While non-piloted flames exhibit tight cone angles and small inner recirculation zones (IRZ), sufficient piloting results in a wide cone angle and a large IRZ. Only in the latter case, the main flow becomes attached to the combustor liner. Flame structures deduced from flow fields and CH-Chemiluminescence images depend on both the pilot fuel injection and liner cooling.


Author(s):  
T. Providakis ◽  
L. Zimmer ◽  
P. Scouflaire ◽  
S. Ducruix

Burners operating in lean premixed prevaporized (LPP) regimes are considered as good candidates to reduce pollutant emissions from gas turbines. Lean combustion regimes result in lower burnt gas temperatures and therefore a reduction on the NOx emissions, one of the main pollutant species. However, these burners usually show strong flame dynamics, making them prone to various stabilization problems (combustion instabilities, flashback, flame extinction). To face this issue, multi-injection staged combustion can be envisaged. Staging procedures enable fuel distribution control, while multipoint injections can lead to a fast and efficient mixing. A laboratory-scale staged multipoint combustor is developed in the present study, in the framework of LPP combustion, with an injection device close to the industrial one. Using a staging procedure between the primary pilot stage and the secondary multipoint one, droplet and velocity field distributions can be varied in the spray that is formed at the entrance of the combustion chamber. The resulting spray and the flame are characterized using OH-Planar Laser Induced Fluorescence, High Speed Particle Image Velocimetry and Phase Doppler Anemometry measurements. Three staging values, corresponding to three different flame stabilization processes, are analyzed, while power is kept constant. It is shown that mean values are strongly influenced by the fuel distribution and the flame position. Using adequate post-processing, the interaction between the acoustic field and the droplet behavior is characterized. Spectral analysis reveals a strong acoustic-flame coupling leading to a low frequency oscillation of both the velocity field and the spray droplet distribution. In addition, acoustic measurements in the feeding line show that a strong oscillation of the acoustic field leading to a change in fuel injection, and hence droplet behavior.


2001 ◽  
Vol 7 (6) ◽  
pp. 375-385 ◽  
Author(s):  
R. C. Hendricks ◽  
D. T. Shouse ◽  
W. M. Roquemore ◽  
D. L. Burrus ◽  
B. S. Duncan ◽  
...  

The Trapped Vortex Combustor (TVC) potentially offers numerous operational advantages over current production gas turbine engine combustors. These include lower weight, lower pollutant emissions, effective flame stabilization, high combustion efficiency, excellent high altitude relight capability, and operation in the lean burn or RQL modes of combustion. The present work describes the operational principles of the TVC, and extends diffuser velocities toward choked flow and provides system performance data. Performance data include EINOx results for various fuel-air ratios and combustor residence times, combustion efficiency as a function of combustor residence time, and combustor lean blow-out (LBO) performance. Computational fluid dynamics (CFD) simulations using liquid spray droplet evaporation and combustion modeling are performed and related to flow structures observed in photographs of the combustor. The CFD results are used to understand the aerodynamics and combustion features under different fueling conditions. Performance data acquired to date are favorable compared to conventional gas turbine combustors. Further testing over a wider range of fuel-air ratios, fuel flow splits, and pressure ratios is in progress to explore the TVC performance. In addition, alternate configurations for the upstream pressure feed, including bi-pass diffusion schemes, as well as variations on the fuel injection patterns, are currently in test and evaluation phases.


Author(s):  
Theodore Providakis ◽  
Laurent Zimmer ◽  
Philippe Scouflaire ◽  
Sébastien Ducruix

Burners operating in lean premixed prevaporized (LPP) regimes are considered as good candidates to reduce pollutant emissions from gas turbines. Lean combustion regimes result in lower burnt gas temperatures and therefore a reduction on the NOx emissions, one of the main pollutant species. However, these burners usually show strong flame dynamics, making them prone to various stabilization problems (combustion instabilities, flashback, flame extinction). To face this issue, multi-injection staged combustion can be envisaged. Staging procedures enable fuel distribution control, while multipoint injections can lead to a fast and efficient mixing. A laboratory-scale staged multipoint combustor is developed in the present study, in the framework of LPP combustion, with an injection device close to the industrial one. Using a staging procedure between the primary pilot stage and the secondary multipoint one, droplet and velocity field distributions can be varied in the spray that is formed at the entrance of the combustion chamber. The resulting spray and flame are characterized using OH-planar laser induced fluorescence, high speed particle image velocimetry, and phase Doppler anemometry measurements. Three staging values, corresponding to three different flame stabilization processes, are analyzed, while power is kept constant. It is shown that mean values are strongly influenced by the fuel distribution and the flame position. Using adequate postprocessing, the interaction between the acoustic field and the droplet behavior is characterized. Spectral analysis reveals a strong acoustic-flame coupling leading to a low frequency oscillation of both the velocity field and the spray droplet distribution. In addition, acoustic measurements in the feeding line show that a strong oscillation of the acoustic field leads to a change in fuel injection, and hence droplet behavior.


1992 ◽  
Vol 58 (545) ◽  
pp. 236-241
Author(s):  
Masashi TAKEBE ◽  
Tatsuro TSUKAMOTO ◽  
Susumu HASEGAWA ◽  
Takashi NIIOKA

1997 ◽  
Vol 119 (3) ◽  
pp. 553-558 ◽  
Author(s):  
K. Do¨bbeling ◽  
A. Eroglu ◽  
D. Winkler ◽  
T. Sattelmayer ◽  
W. Keppel

The paper reports on the development and testing of a premix research burner for MBtu fuels. The burner has a quartz glass annular mixing section and a quartz, glass flame tube to allow visualization of the flame. A central lance is used to mount modules for fuel injection, swirl generation, and flame stabilization. This allows a large number of variants with different swirl strength, mixing section length, fuel injection geometry, and flameholder size and shape to be easily tested. Experiments have been performed at atmospheric pressure and under high-pressure conditions (14 bar pressure, 400°C air preheat temperature) for syngas with a H2/CO ratio of up to 5. In a preliminary study, the mixing quality of the tested variants has been assessed with planar laser-induced fluorescence (LIF). High-pressure combustion tests show that low NOx (<10 vppmd @ 15 percent O2) premix combustion of MBtu fuels under industrial GT conditions without dilution is feasible.


Sign in / Sign up

Export Citation Format

Share Document