Echocardiographic Particle Image Velocimetry: A Novel Technique for Quantification of Left Ventricular Blood Vorticity Pattern

2010 ◽  
Vol 23 (1) ◽  
pp. 86-94 ◽  
Author(s):  
Arash Kheradvar ◽  
Helene Houle ◽  
Gianni Pedrizzetti ◽  
Giovanni Tonti ◽  
Todd Belcik ◽  
...  
Author(s):  
Jean Brunette ◽  
Rosaire Mongrain ◽  
Rosaire Mongrain ◽  
Adrian Ranga ◽  
Adrian Ranga ◽  
...  

Myocardial infarction, also known as a heart attack, is the single leading cause of death in North America. It results from the rupture of an atherosclerotic plaque, which occurs in response to both mechanical stress and inflammatory processes. In order to validate computational models of atherosclerotic coronary arteries, a novel technique for molding realistic compliant phantom featuring injection-molded inclusions and multiple layers has been developed. This transparent phantom allows for particle image velocimetry (PIV) flow analysis and can supply experimental data to validate computational fluid dynamics algorithms and hypothesis.


Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Haruhiko Abe ◽  
Kasumi Masuda ◽  
Toshihiko Asanuma ◽  
Hikaru Koriyama ◽  
Yukihiro Koretsune ◽  
...  

Background: Vortex flow in the left ventricle (LV) has three-dimensional structure and plays an important role in avoiding excessive dissipation of energy. However, quantitative characteristics of long and short axis (LAX and SAX) vortex flow have not been elucidated. Echocardiographic particle image velocimetry (Echo-PIV) is an emerging technique to evaluate instantaneous vortical flow inside the LV. However, it has a limitation of underestimation of high velocities due to limited frame rate. Moreover, previous investigations have mainly focused on vortex from LAX view. Therefore, we used high frame rate Echo-PIV to quantitate vortex flow in SAX as well as in LAX views to understand characteristics of vortex three-dimensionally. Methods: Echocardiographic contrast images of the LV SAX and LAX were acquired from 8 open-chest healthy dogs. The acquisition frame rate was 135 frames per second and the contrast bubbles density was optimized for blood flow analysis. Echo-PIV analysis was performed off-line by using commercially available software and vorticity data were calculated in the region of interest (ROI) throughout the cardiac cycle. ROI was manually placed on the vortex. Vortex strength was defined as the averaged vorticity within the ROI. Results: In SAX, counterclockwise vortex was seen near the anterior wall, and in LAX clockwise vortex was seen in the anterior mid-ventricle. Both in SAX and LAX views, vortex strength showed significant phasic variations being largest in isovolumic contraction (vortex strength, SAX 9.2±2.3/s, p<0.001; LAX -12.0±2.4/s, p<0.001), and smallest in isovolumic relaxation (SAX -0.8±0.8/s, p<0.001; LAX -1.9±1.9/s, p<0.001). Conclusion: High frame rate Echo-PIV successfully demonstrated a complicated pattern of intracardiac vortex with phasic variation of its strength throughout a cardiac cycle in both SAX and LAX. This method may be a useful tool to assess physiological role of vortex in the flow dynamics.


2017 ◽  
Vol 35 (1) ◽  
pp. 56-63 ◽  
Author(s):  
Chouchou Tang ◽  
Yizhong Zhu ◽  
Jing Zhang ◽  
Chengcheng Niu ◽  
Dan Liu ◽  
...  

Author(s):  
Arend F. L. Schinkel ◽  
Sakir Akin ◽  
Mihai Strachinaru ◽  
Rahatullah Muslem ◽  
Dan Bowen ◽  
...  

Abstract Purpose Poor left ventricular (LV) function may affect the physiological intraventricular blood flow and physiological vortex formation. The aim of this study was to investigate the pattern of intraventricular blood flow dynamics in patients with LV assist devices (LVADs) using echocardiographic particle image velocimetry. Materials and methods This prospective study included 17 patients (mean age 57 ± 11 years, 82% male) who had received an LVAD (HeartMate 3, Abbott Laboratories, Chicago, Illinois, USA) because of end-stage heart failure and poor LV function. Eleven (64%) patients had ischemic cardiomyopathy, and six patients (36%) had nonischemic cardiomyopathy. All patients underwent echocardiography, including intravenous administration of an ultrasound-enhancing agent (SonoVue, Bracco, Milan, Italy). Echocardiographic particle image velocimetry was used to quantify LV blood flow dynamics, including vortex formation (Hyperflow software, Tomtec imaging systems Gmbh, Unterschleissheim, Germany). Results Contrast-enhanced ultrasound was well tolerated in all patients and was performed without adverse reactions or side effects. The LVAD function parameters did not change during or after the ultrasound examination. The LVAD flow was on average 4.3 ± 0.3 L/min, and the speed was 5247 ± 109 rotations/min. The quantification of LV intraventricular flow demonstrated substantial impairment of vortex parameters. The energy dissipation, vorticity, and kinetic energy fluctuation indices were severely impaired. Conclusions Echo particle velocimetry is safe and feasible for the quantitative assessment of intraventricular flow in patients with an LVAD. The intraventricular LV flow and vortex parameters are severely impaired in these patients.


2018 ◽  
Vol 140 (4) ◽  
Author(s):  
Kaushik Sampath ◽  
Thura T. Harfi ◽  
Richard T. George ◽  
Joseph Katz

Contrast ultrasound is a widely used clinical tool to obtain real-time qualitative blood flow assessments in the heart, liver, etc. Echocardiographic particle image velocimetry (echo-PIV) is a technique for obtaining quantitative velocity maps from contrast ultrasound images. However, unlike optical particle image velocimetry (PIV), routine echo images are prone to nonuniform spatiotemporal variations in tracer distribution, making analysis difficult for standard PIV algorithms. This study introduces optimized procedures that integrate image enhancement, PIV, and particle tracking velocimetry (PTV) to obtain reliable time-resolved two-dimensional (2D) velocity distributions. During initial PIV analysis, multiple results are obtained by varying processing parameters. Optimization involving outlier removal and smoothing is used to select the correct vector. These results are used in a multiparameter PTV procedure. To demonstrate their clinical value, the procedures are implemented to obtain velocity and vorticity distributions over multiple cardiac cycles using images acquired from four left ventricular thrombus (LVT) patients. Phase-averaged data elucidate flow structure evolution over the cycle and are used to calculate penetration depth and strength of left ventricular (LV) vortices, as well as apical velocity induced by them. The present data are consistent with previous time-averaged results for the minimum vortex penetration depth associated with LVT occurrence. However, due to decay and fragmentation of LV vortices, as they migrate away from the mitral annulus, in two cases with high penetration, there is still poor washing near the resolved clot throughout the cycle. Hence, direct examination of entire flow evolution may be useful for assessing risk of LVT relapse before prescribing anticoagulants.


2019 ◽  
Vol 41 (6) ◽  
pp. 336-352 ◽  
Author(s):  
Sri Oktamuliani ◽  
Naoya Kanno ◽  
Moe Maeda ◽  
Kaoru Hasegawa ◽  
Yoshifumi Saijo

Echodynamography (EDG) is a computational method to estimate and visualize two-dimensional flow velocity vectors by applying dynamic flow theories to color Doppler echocardiography. The EDG method must be validated if applied to human cardiac flow function. However, a few studies of flow estimated have compared by EDG to the flow data were acquired by other methods. In this study, EDG was validated by comparing the analysis of estimating and visualizing flow velocity vectors obtained by original particle image velocimetry (PIV) based on a left ventricular (LV) phantom hydrogel (in vitro studies) and by EDG based on the virtual Doppler velocity. Velocity measured by PIV method and velocity estimated by EDG method in the perpendicular direction and the radial direction were compared. Regression analysis for the velocity estimated in the radial direction revealed an excellent correlation ([Formula: see text], slope = 0.96) and moderate correlation in the perpendicular direction ([Formula: see text], slope = 0.46). As revealed by the Bland–Altman plot, however, overestimations and higher relative error were observed in the perpendicular direction (0.51 ± 2.75 mm/s) and in the radial direction (–2.15 ± 21.13 mm/s). The percentage error of the norm-wise relative error of the velocity discrepancy is less than [Formula: see text], and velocity magnitude followed the same trends and are of comparable magnitude. These findings indicate that good estimates of velocity can be obtained by the EDG method. Therefore, the EDG method was appropriate for estimating and visualizing velocity vectors in clinical studies for higher measurement accuracy and reliability. The clinical in vivo application showed that the EDG method has the ability to visualize blood flow velocity vectors and differentiate the clinical information of vortex parameters both in normal and abnormal LV subjects. In conclusion, the EDG method has potentially greater clinical acceptance as a tool assessment of LV during the cardiac cycle.